13
4.1
Sensor Installation
1.
Remove the inner height sensors and the inner brackets. Keep these sensors as spares.
2.
Mount the inner wing sensor brackets approximately half-way between the chassis and the
outer wing sensors.
3.
For the 90’ and 100’ booms, a mounting spacer (B12) is supplied to provide clearance for
the liquid supply line. For 120’ booms, the inner sensor bracket can be mounted directly to
the boom. Mount the spacers (B12) onto the brackets using the bolts (M10) and lock nuts
(M09). Mount the inner wing sensor brackets using the u-bolts (M08) and lock nuts (M09)
as shown in Figure 11.
4.
Install the sensors (E07) into the brackets with the lower serial number on the left (Figure
10). Connect the sensors where the original sensors were disconnected.
Figure 10: Sensor Serial Number Arrangement
The E07 sensors will be mounted in the positions shown in black.