background image

500-004-05 UK

ISOCAN / ISOBUS Artemis AS1

Seed Drill Controller

Installation Manual

Summary of Contents for ISOBUS Artemis AS1

Page 1: ...500 004 05 UK ISOCAN ISOBUS Artemis AS1 Seed Drill Controller Installation Manual...

Page 2: ......

Page 3: ...ent IMPORTANT You must read and follow the Documentation and complete appropriate training before use If You do not operate the System properly it may not correctly apply the Application to Your requi...

Page 4: ...at the area of Machine operation is clear of people animals and obstacles and identify any other possible hazards Keep other persons required to be in the vicinity of the Machine fully aware of Your i...

Page 5: ...itch 16 3 6 Seed Shaft Confirmation Sensor 17 3 7 Metering unit setup 17 3 8 Hopper Level sensors 18 3 8 1 Hopper level sensor configuration 18 4 ECU AND SENSORS 19 4 1 Fan Speed Sensor 19 4 2 Area Cu...

Page 6: ...ingle product setup Kit P BLOCK SIN 29 6 2 Dual product setup Kit P BLOCK DUAL 30 6 3 Sensors 30 6 3 1 Sensor and Row numbering 31 6 4 Blockage sensor configuration 31 6 4 1 Enable blockage monitoring...

Page 7: ...for each additional control channel Seed Fert P ART3 2ND NM Kit as above but without motor for utilising an existing motor Required for each additional control channel Seed Fert 1 2 Drill Configuratio...

Page 8: ...C 1015540 01 Expansion Harness Tramline actuators not supplied by Topcon Hopper level 1 sensor 11 S CB 411 1 026 Seed blockage sensors optional S HU 410 3 002 Satspeed 2 ECU Assembly S CB 410 3 020 Fa...

Page 9: ...d Shaft 1 Confirmation Sensor S TC 1015540 01 Expansion Harness Tramline actuators not supplied by Topcon Hopper level 1 sensor 40 S CB 500 1 156 Seed blockage sensors optional ISOBUS UT not included...

Page 10: ...Cable Kit Ref P ART2 EXT 4M option for trailed drills A 4m extension cable kit for use with trailed drills Figure 5 Kit Ref P ART2 EXT 4M Cable Extension Kit Item Part No Description Qty 70 S CB 318 1...

Page 11: ...lder 1 1 1 29 S T610 111 Wire Terminal D25 6 2 2 2 30 S T609 071 Wire Terminal Yellow Ring 8 8 8 4 4 Implement based components Figure 8 40 S CB 500 1 156 ISOBUS Cable 1 1 41 S CB 410 3 020 ISOBUS Ext...

Page 12: ...ISOCAN ISOBUS ARTEMIS SEED DRILL CONTROLLER 10 Figure 6 Tractor based components Figure 7 Implement High current Power Supply components K ART2 PWR 10 11 12 13 21 22 23 24 25 26 27 28 29 30...

Page 13: ...ISOCAN ISOBUS ARTEMIS SEED DRILL CONTROLLER 11 Figure 8 Implement based components 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 49...

Page 14: ...land drive connection point otherwise any half width clutch if fitted may not function correctly Fit the shaft 47 to the appropriate side of the gearbox Shorten or otherwise modify the existing landwh...

Page 15: ...he red wire to 12V and the black wire to 0V Simply reverse the connections onto the MCM to rotate in the opposite direction 2 1 2 Motor Connections Each motor is connected to a Motor Control Module as...

Page 16: ...rear of the tractor or to the front for a front mounted hopper Route the Implement Power Cable 24 to a point central to the MCM modules Mount the Fuseholder 28 Cut the red wire to length and connect t...

Page 17: ...s are more than 500mm from a master grounding point on chassis 13 28 26 26 MCM 2 29 MCM 1 24 29 25 25 MASTER GROUNDING POINT 13 26 26 MCM 1 29 28 29 25 24 MASTER GROUNDING POINT MCM 2 25 57 24 Expansi...

Page 18: ...uld be set to half the full working width Linked When a configuration requires multiple hoppers metering units to dispense a single product then the control channels are linked Two three or four singl...

Page 19: ...ing units a 2nd Seed Shaft Confirmation Sensor may be plugged into connector G of the Expansion Harness S TC 1015540 01 for that motor 3 7 Metering unit setup The only setting that may require changin...

Page 20: ...rent products Route the cable s back to connector E for sensor 1 and connector D for sensor 2 of the Expansion Harness S TC 1015540 01 For multi channel systems where level sensors are installed for e...

Page 21: ...ISOBUS installations the area cutout signal is normally provided from the Topcon retrofitted area cutout switch A second drill lowered switch optional may be also installed to operate in conjunction...

Page 22: ...en if the drill lowered finger switch closes again the motor operation will be resumed and work status will be in work N B When the Lift Lower function is switched ON then tramline advance will occur...

Page 23: ...hould not be fitted in situations where speed measurement 0 5km hr is required or there is consistent poor quality GPS reception On initial power up it may take up to 5 minutes depending on the recept...

Page 24: ...EGNOS support Flashes VTG message frequency e g 4Hz 4 3 2 GPS ISOBUS If for whatever reason the Satspeed 2 is not utilised and Forward speed signal is instead obtained from the ISOBUS then set Speed S...

Page 25: ...and TL2 Please refer to section 5 2 2 for connection information NOTE Electrical Interference Suppression When interfacing with solenoids they must be adequately suppressed to prevent the possibility...

Page 26: ...e mechanisms 4way Deutsch Receptacle DT04 4P Pin Wire Colour Function TL1 1 Yellow Green Tramline 1 Right V TL1 2 Blue 0V TL1 3 Brown Tramline 1 Right V TL1 4 TL2 1 Yellow Green Tramline 2 Left V TL2...

Page 27: ...ID Connector Function Notes MCM Cinch 18way MCM A AMP Superseal 1 5 3way Socket Motor Encoder B Deutsch DT06 6S Expansion In Power CAN C Deutsch DT04 6P Expansion Out Power CAN D Deutsch DT04 3P Hopp...

Page 28: ...the Cinch connector Connections MCM Pin Wire colour Function 1A Gray V 1B Pink Encoder SIG 1C Black Shaft Conf 1 SIG 1D Green CAN LO 1E Yellow CAN HI 1F Yellow Black CAN Termination Link 2A White 2B...

Page 29: ...Plug DT06 6S CAN Power MCM Connects to MCM 1 AREA CUTOUT Deutsch 3way Receptacle DT04 3P Area Cutout Switch S SW 500 7 018 Std LOWER SWITCH CUTOUT Lower Cutout Switch S SW 500 7 018 optional FAN 1 Fa...

Page 30: ...Blue CON 1 6 0V C Brown CON 1 2 Area Cutout Switch SIG LOWER SWITCH CUTOUT Deutsch 3way Receptacle DT04 3P A n c B Blue CON 1 6 0V C Brown CON 1 2 Lower Area Cutout Switch SIG FAN 1 Deutsch 3way Rece...

Page 31: ...Blockage ECU single product 1 81 S CB 500 1 155 20ft 6M Extension Cable 2 82 S CB 500 1 176 Blockage ECU Power Harness 1 The master ECU is normally mounted on the front of the drill The Extension Lead...

Page 32: ...atic applicable to systems with up to 60 sensors per channel 6 3 Sensors Sensors are supplied seperately and are available in three sizes Part No Pipe bore S SR 500 2 099 30mm S SR 500 2 100 32mm 1 1...

Page 33: ...unctions Setup in the Artemis app as follows 1 Cycle to the Setup screen touch the tab scroll down and select Blockage and tick box to enable 2 Cycle to the Blockage Sensor screen that now appears as...

Page 34: ...larms when drilling half width or with auto section control Set if a tramline row Left or Right prevents false alarms on tramline bouts 8 Repeat for the fert sensors as necessary 6 4 4 Diagnostics 1 C...

Page 35: ...ISOCAN ISOBUS ARTEMIS SEED DRILL CONTROLLER 33 Issue Ref Date Notes 1 0 8 2 18 Original issue derived from UK863 C...