![Topcon GPT-3000W Series Instruction Manual Download Page 176](http://html1.mh-extra.com/html/topcon/gpt-3000w-series/gpt-3000w-series_instruction-manual_1128632176.webp)
23-3
23 SPECIFICATIONS
Laser pointer
Light source
: LD (Visible laser)
Wave length
: 690nm
Out put
: 1mW maximum
Laser class
: Class 2(IEC Publication 825)
: Class II(FDA/BHR 21 CFR 1040)
Laser Plummet (only for Laser plummet type)
Light source
: L.D (Visible laser)
Wave length
: 633nm
Out put
: 1mW maximum
Laser class
: Class 2(IEC Publication 825)
: Class II(FDA/BHR 21 CFR 1040)
Dimension : 336(H)
×
184(W)
×
174(L) mm
(13.2(H)
×
7.2(W)
×
6.9(L) in)
Weight
Instrument
(with battery)
: 5.2kg ( 11.4 lbs)
(without battery)
: 4.9kg ( 10.8 lbs)
Plastic carrying case
: 3.2kg ( 7.1 lbs)
(Weight of the carrying case may be slightly different
due to specific market.)
Durability
Protection against water and dust
: IP66 (with BT-52QA)
(Based on the standard IEC60529)
Ambient Temperature Range
: –20°C to +50°C (–4°F to +122°F)
Battery BT-52QA (This battery does not contain mercury.)
Out put voltage
: 7.2 V
Capacity
: 2,700 mAh (Ni-MH)
Weight
: 0.3kg ( 0.7 lbs)
Maximum operating time (when fully recharged) at +20°C (+68°F)
Select Bluetooth™ Port
Including distance measurement
: Approx. 4.0hours
Angle measurement only
: Approx. 25hours
Select RS-232C Port
Including distance measurement
: Approx. 4.2hours
Angle measurement only
: Approx. 45hours
Battery Charger BC-27BR / BC-27CR
Input voltage
: AC 120V(BC-27BR), AC 230V(BC-27CR)
Frequency
: 50/60Hz
Recharging time (at +20°C /+68°F)
Battery BT-52QA
: 1.8 hours
Discharging time (at +20°C /+68°F)
Battery BT-52QA
: 8 hours (in case of full charge)
Operating temperature
: +10°C to +40°C ( +50°F to +104°F)
Charging signal
: Red lamp illumination
Refreshing signal
: Yellow lamp illumination
Finishing signal
: Green lamp illumination
Weight
: 0.5kg (1.1 lbs)
●
Battery using time will vary depending on environmental conditions and operations done with
GPT-3000W series.