Setting parameters on the PJEZ-S 

 

Preliminary Configurations 

 

Summary of Contents for ISLA

Page 1: ...Integral Promotional Serve Over Installation Operation Maintenance Manual Integral Promotional Serve Over Cabinet ISLA ...

Page 2: ...gs 4 Technical Data Sheet 5 Transport and Delivery 6 Location of your Display Case 7 Installation 8 Operation 9 Usage 10 Setting parameters on the PJEZS 11 Controller Error and Alarm Messages 12 Maintenance 13 Check Plan 14 After Sales Service 15 Troubleshooting 16 Electrical Wiring Diagram for Akdeniz 17 Declaration of Conformity ...

Page 3: ...manual HIGH VOLTAGE RISK If you have no licence install electrical components do not interfere to the cabinet or control board Contact with the qualified persons or with Topcold Technical Service when you purchase a new cabinet or meet with a failure of the cabinet Do not open and do not touch to insulated connection ...

Page 4: ...tractively designed to optimise display of chilled products Case is coming with wheels aluminium bars and condensate water evaporator makes merchandising quick simple and durable DECODING Model Name Case Length Akdeniz 977 5 1290 Do not load each tray with merchandises heavier than 100 kg m ...

Page 5: ...Integral Promotional Serve Over Akdeniz 3 Sectional Drawings ...

Page 6: ... 1250 Condensate Heater Climate Class 3 25 ºC 60RH EN ISO 23953 1 EN ISO 23953 2 Unit 1014 R449a Refrigeration Data Exp Valve Orifice No Danfoss TEV Evaporator Fan Motors Diameter incl Blade Length Height Heaters W 400 937 2x 25 55 N A Canopy Lighting T5 Shelf Lighting T8 Condenser Fan 220 240 Canopy Lighting T8 4 Technical Data Sheet Data specified in the above table is based on the following par...

Page 7: ...y Transport Cases always should be transport in the upright position Cases should be handled with care Avoid dropping or jolting the case which may cause damage Remove packaging carefully Special packing style with bubbled nylon helps to protect sensitive surfaces ...

Page 8: ...k brakes on castors or by unscrewing the legs longer then castors Adjustable feet and castors with brake Do not expose the case direct sunlight or other sources of heat Avoid incandescent lighting Avoid locations where the case may be knocked by cleaning machines and pallets Access Ensure that the case is easily accessible for loading and unloading Place the in a prominent position within the stor...

Page 9: ...performance Do not locate the case close draught such as doors open windows or air conditioning vents Make sure air return grille is open Make sure air off grille is open 7 Installation Assembly Assembly installation and connection of the case should always be undertaken by appropriately qualified personal Tempered Glasses Epos glass should be put in to the canal in front of the air return grill ...

Page 10: ...in to drop to its pre set value For the pre set temperature for your specific model please refer to the Technical Data Sheet Section Turn on the light switch on the control panel The light and refrigeration switch are located onto the front canopy at the right hand of cabinet The light switch is next to the refrigeration switch The digital controller is located next to the power switch Merchandisi...

Page 11: ...emperature class M2 Always load cases within conservation product temperature Before turning it on clean inside and outside of the cabinet with soft tissue moistened by water which contains detergent harmless for surfaces Place the foodstuffs steady and accurate onto shelves P S Never exceed maximum loading limit sign which is shown in the picture ...

Page 12: ...t Point Maximum r2 r1 End of Defrost Temperature ALARM PARAMETERS High Temperature Alarm AH Usage continued As standard the case is supplied with a Carel PJEZ S full functional electronic controller incorporating an LED thermometer which displays average case operating temperature The controller is factory pre set but parameters may be programmed as detailed below Reprogrammed parameters take imme...

Page 13: ... been set To set minimum temperature limit parameter Ensure that the case is switched on and lights fans and compressor are running Press SET button for a count of more 5 seconds until P5 is displayed on LED Press SET button again 0 appears on the screen Use up and down buttons until 22 displayed on LED Press SET button and see d0 Change the value with up and down buttons Press SET again and see d...

Page 14: ...Integral Promotional Serve Over Akdeniz Setting parameters on the PJEZ S Preliminary Configurations ...

Page 15: ...ver Akdeniz 11 Controller Error and Alarm Messages A variety of error and alarm messages may be displayed on the LED of the electronic controller The codes are detailed below Please note that e2 may not be available in some models ...

Page 16: ...Put gloves on before starting maintenance Do not touch hot and moving parts Amount of the ice in evaporator must be checked every day in first week after installation and twice a week after first week If abnormal amounts of ice are noticed the cabinet must be set to regular working conditions by manual defrosting 12 1 Cleaning 12 1 1 General A regular and thorough cleaning regime is essential for ...

Page 17: ...es may be buffed with a soft dry cloth 12 1 4 Case Well Lift out deck trays and sweep or vacuum any debris from the case well The well may be wiped with a cloth and mild disinfectant 12 1 5 Fan Deck Lift the fan plate allow claening around the fans Make sure that fans are not running Never take off the fan guards Never try to stop the fans with your hands while they are running 12 1 6 Cooling Fins...

Page 18: ...etting enough refrigeration in the case 12 2 2 Case Inspection Operating temperature as indicate on the controller mounted in front of the case should be checked on dialy basis Case should be monitored on a daily basis for any undue noise smell or malfunction Regularly inspect the case for ice cream spillage or debris in the air grilles and case well Remove and clean spillages and debris 12 2 3 Cl...

Page 19: ...ondenser X Cleaning of evaporator X Checking of the digital controllers display X Checking of icing up of the evaporator X Cleaning of the case drain X Checking of the case circulation fans X Checking of the condenser fan s X Checking of the air off at grilles X Condenser Evaporator Display Drain and circulation fans Air off and air return grilles ...

Page 20: ...their operating temperatures and note them Any maintenance operation not included among the former steps must be carried out by the authorised after sales service or by qualified personel You can refer the troubleshooting tables in this document 14 After Sales Service Contact your agent when you need technical assistance If you need parts contact your after sales service Manufacturer recommends us...

Page 21: ...Integral Promotional Serve Over Akdeniz 15 Troubleshooting ...

Page 22: ...Integral Promotional Serve Over Akdeniz 16 Electrical Wiring Diagram for Akdeniz ...

Page 23: ...Integral Promotional Serve Over Akdeniz 17 Declaration of Conformity ...

Page 24: ...Integral Promotional Serve Over Akdeniz ...

Page 25: ...Integral Promotional Serve Over Akdeniz ...