background image

Portable Jr

i  Conditioners

Manual Temperature-Control System

The manual temperature control system allows you to set

the desired temperature by simply rotating the
WARMER/COOLER dial either left or ri

g

ht. The

supply air fan can be set to run continuously whether the

cooling circuit cycle is on and off. or can be set to cycle
on and off with the cooling circuit.

Filter

All units are equipped with removable, washable.

aluminum-mesh air filters. Located behind the return-air
and discharge-air grilles, these can be removed and

easily cleaned.

Ceiling-Panel Duct Kit

A ceiling-panel duct kit comes complete with flexible

duct and a 2-ft by 2-ft ceiling-tile adapter which allows
condenser air to be vented to the plenum area above a

suspended ceiling.

Discharge Nozzle Kit

A dual-nozzle. discharge-air assembly optimizes the
ability to direct cool 

air 

precisely where needed. The

flexible nozzles are attached to a mounting plate that fits
over the evaporator-air grille. See Accessory

Information on page 11 for proper sizing.

Condensate Pump

A condensate pump automatically drains the condensate
pan by removing evaporator-coil water allowing

continuous operation_ The pump is connected to the

condensate drain and to the air conditioner's power
supply. A hose runs from the unit to a convenient drain

or outdoor location.

Cord Kit (LCDI) (TZ-12A, 18A, 24A, 36A)

The LCDI cord set provides both personal shock as well

as cord arcing and fire protection. Use the LCDI cord
kit provided by RUPP Industries, Inc.

Condensate Tank

A five-gallon. polyethylene tank in the lower-front
compartment of the unit collects evaporator-coil
condensate moisture. When full. the weight of the tank

activates a cutout switch. turning the refrigeration circuit
OFF and illuminating the condensate tank-full light on

the unit's front. The tank is readily accessible behind a

hinged door. Simply remove, drain, replace. and restart.

Note: 

The unit will not operate unless the tank is
drained periodically. An optional condensate
pump is available for continuous operation.

Optional Features

Condenser Duct

Condenser discharge air can be removed from the
conditioned space with flexible duct. Use 40-ft

maximum for all models. Allow six feet for every 90°
bend. Do not exceed 0.10-in we external static pressure
at the condenser.

5

Air Marketing Group LLC

141 kincierkarnack Rd. Park Ridge. NJ 07655 Tel. 201-782-1782 Fax. 201-782-1783 Web: vwvw.amgair.corn Email: info@amgaircom

Summary of Contents for TZ-12A

Page 1: ...RUPP Industries reserves the right to change design and specifications without prior notice OTomx Portable Air Conditioners Owner s Manual 1 800 836 7432 Unit Specifications 3 Rating Information 3 In...

Page 2: ...type 5 1 5P 5 15P 6 20P 6 30P wired wired ER rating 10 4 12 8 10 3 10 0 8 9 8 3 Evaporator FM free discharge 350 600 750 1 200 2 300 2 300 Condenser CFM 500 1 000 1 000 1 500 3 900 3 900 Maximum esp...

Page 3: ...ir Conditioners have removable side panels for easier servicing from all sides The interior of the unit is divided into four sub compartments The upper rig ht encloses the evaporator coil and fan and...

Page 4: ...orator coil water allowing continuous operation_ The pump is connected to the condensate drain and to the air conditioner s power supply A hose runs from the unit to a convenient drain or outdoor loca...

Page 5: ...ng circuit will cycle on and off Press the COOL FAN AUTO switch for cyclin g the fan operating on and off with the cooling circuit Cooling Cycle 1 Set the desired temperature by adjusting the WARMER C...

Page 6: ...tioned air and condenser air are controlled using double inlet forward curved fans driven by belt and sheave combinations Adjust belt tension for 3 16 in deflection with 2 lbs force Sheave Adjustment...

Page 7: ...ndensate tank Check tank if full remove tank empty and replace If unit comes back on replace detective light See pg 10 Replace Unit must have either condensate pump or condensate jump plug installed t...

Page 8: ...securely attached to evaporator coil s outlet and that insulation is in place Check wiring connections to freeze protection control Check condition and adjustment of evaporator and condenser fan belt...

Page 9: ...6 1 Remove cabinet s side panels 2 Disconnect evaporator motor wires at the connector plug 3 Disconnect condenser motor wires at the connector plug 4 Remove unit s top and disconnect thermostat at con...

Page 10: ...TZ 24 TZ 36 and TZ 60 CP 1 10 in condenser return air plenum TZ 12 CP 2 14 in condenser return air plenum TZ 18 and TZ 24 CP 3 14 in condenser return air plenum TZ 36 CP 4 20 in condenser return air...

Page 11: ...OA 1Z BOA 5 88400 284 88400 249 88400 250 88400 251 two 88400 256 83201 017 83201 029 83200 169 88401 025 88401 030 88401 028 88401 029 88401 031 83100 102 83100 159 83100 117 83100 118 80500 138 856...

Page 12: ...256 88000 043 88000 044 two 88000 014 87300 242 two 87300 258 86300 050 80700 112 80700 051 84900 044 83800 004 87500 128 83200 17 83200 172 83200 73 83200 174 83200 160 83200 161 83200 162 83200 175...

Page 13: ...81300 030 84900 054 87800 090 87800 091 87800 092 87800 087 99900 302 99900 303 86900 033 86900 553 86900 029 86900 554 88000 058 88800 165 83500 035 four 87300 416 two remote thermostat probe drain...

Page 14: ...8 volt for no volt units 1 3 J1 7 G Condensate Pump II Motor el o Condor mute Flout Swish 1 4 Con elan suite Pump Overf low Switch eielired when PC 1 is not irmicH Start Coal Kik sr 1 l J1 5 J1 6 Y J1...

Page 15: ...ndensate Compartment J1 Cond ensete Compartment BL J2 5 F 1 0 J2 5 I Conde nsote Full Light Fan ON AUTO Switch BL Therm ostat High Prmssure Gonde nee r Switch Relay RE 01 Off AUTO J1 8 BR 0 11 Jumper...

Page 16: ...PC 1 Portab e Industrial Jr i Conditioners Wiring Schematic TZ 60A Evoponotor Blower Motor ol l oc Cm den ae r RIF war C nprinioear th Fre rtOF Overload Contact ste tf m Control 11 0 J1 2 Co nt N ti e...

Page 17: ...N PC 1 r J1 3 Oa ridonsots Pump Overf I p r Sectch Comp reseal Starker Portable Industrial Air Conditioners Wiring Schematic TZ 60A4 TOPAZ Owner s Manual Air Marketing Group LLC 18 141 kinrierkarnack...

Page 18: ...3700 West Preserve Boulevard Burnsville Minnesota 55337 7746 1 800 836 7432 Air Marketing Group LLC 141 kinclerkarnack Rd Park Ridge NJ 07655 Tel 201 782 1782 Fax 201 782 1783 Web vwvw amgaircom Email...

Reviews: