IMPORTANT:
READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING. KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE. Topaz fixtures must be wired in accordance with the
National Electrical Code and all applicable local codes. Proper grounding is required
for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
APPLICABLE
INSTALLATION CODE BY A QUALIFIED ELECTRICIAN WHO IS FAMILIAR WITH
THECONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING:
RISK OF FIRE OR ELECTRIC SHOCK. Topaz Panel Light installation requires knowledge of luminaires and
electrical systems. If not qualified, DO NOT attempt installation. Contact a qualified electrician.
• Turn off electrical power at fuse or circuit breaker box befo
re wiring fixture to the power supply.
• Turn off the power when you perform any maintenance.
WARNING:
Risk of fire or electric shock. Suitable for dry and damp locations. Make sure the power is off prior to installation.
WARNING:
Risk of fire or electric shock. Suitable for flat T-Grid in insulated or non-insulated ceilings. Access above ceiling required.
WARNING:
DO NOT install in unstable, loose or easily breakable surfaces.
WARNING:
DO NOT let objects impact or exert force on the surface of the fixture.
Warranty Information:
This product is warranted for 5 years from the date of purchase, based on 10 hours of use per day. If this product does not
perform to the specifications supplied on this package, send an email or write to the address below for product return and
replacement. This replacement is the sole remedy available. Liability for incidental or consequential damage is expressly
excluded. Visit www.topaz-usa.com for full warranty details.
Wiring Diagram (0-10V Dimmable Panel)
If you have questions regarding these products, call TOPAZ LIGHTING CORP. at 1-800-666-2852 www.topaz-usa.com
Items:
F-L1X4/40W/8ZZ/D-75
F-L2X2/40W/8ZZ/D-75
F-L2X4/50W/8ZZ/D-75
F-L2X4/75W/8ZZ/D-75
www.topaz-usa.com
925 Waverly Ave • Holtsville, NY 11742 • 800-666-2852 • Fax: 631-758-8026
INSTALLATION INSTRUCTIONS FOR HIGH EFFICIENCY PANELS
F-L14/32/8ZZ/D/HP-75
F-L22/32/8ZZ/D/HP-75
F-L24/38/8ZZ/D/HP-75
F-L24/60/8ZZ/D/HP-75
IMPORTANT
READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING. KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE. Topaz fixtures must be wired in accordance with the
National Electrical Code and all applicable local codes. Proper grounding is required for
safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A QUALIFIED ELECTRICIAN WHO IS FAMILIAR WITH THE
CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING
- RISK OF FIRE OR ELECTRIC SHOCK. Topaz Panel Light installation requires knowledge of luminaires and electrical systems.
If not qualified, DO NOT attempt installation. Contact a qualified electrician.
• Turn off electrical power at fuse or circuit breaker box befo
re wiring fixture to the power supply.
• Turn off the power when you perform any maintenance.
WARNING
- Risk of fire or electric shock. Suitable for dry and damp locations. Make sure the power is off prior to installation.
WARNING
- Risk of fire or electric shock. Suitable for flat T-Grid in non-insulated ceilings. Access above ceiling required.
DO NOT cover fixture with insulation liner or similar material.
WARNING
- DO NOT install in unstable, loose or easily breakable surfaces.
WARNING
- DO NOT let objects impact or exert force on the surface of the fixture
Warranty Information:
This product is warranted for 5 years from the date of purchase, based on 10 hours of use per day. If this product does not perform to the
specifications supplied on this package, send an email or write to the address below for product return and replacement. This replacement is the
sole remedy available. Liability for incidental or consequential damage is expressly excluded. Visit www.topaz-usa.com for full warranty details.
LED PANEL LIGHT
INSTRUCTION MANUAL
Items:
If you have questions regarding these products, call TOPAZ LIGHTING CORP. at 1-800-666-2852 http://www.topaz-usa.com
Wiring Diagram (0-10V Dimmable Panel)
F-L2X2/40W/830/D-75
F-L2X2/40W/835/D-75
F-L2X2/40W/840/D-75
F-L2X4/50W/830/D-75
F-L2X4/50W/835/D-75
F-L2X4/50W/850/D-75
F-L2X4/50W/840/D-75
F-L2X4/75W/830/D-75
F-L2X4/75W/835/D-75
F-L2X4/75W/850/D-75
F-L2X4/75W/840/D-75
F-L2X2/40W/850/D-75
F-L1X4/40W/830/D-75
F-L1X4/40W/835/D-75
F-L1X4/40W/840/D-75
F-L1X4/40W/850/D-75
2BQ0077
Green
Black
Red
L(Black)
N(White
)
G(Ground)
Dimmer
)
Gray(-)
Re
d
Panel light
Driver
L
N
G
3
2
1
4
5
6
1.
Line (Hot)
2.
Neutral
3.
Ground
4.
Load
5.
Purple (+)
6.
Gray (-)