OPERATION
-15-
Changing the feed roll groove
The feed roller (No.16 in the picture) is factory set for welding filler wires of 08-1.0mm and
0.6mm diameter on the other side. The feed roller side must be changed if you use 0.6mm thick
filler wire.
Threading the filler wire
Threading the filler wire as the follow steps:
Open the reel housing by pressing on the opening button and install the wire reel in such a way
that it rotates counter clockwise. You can use either a diameter 200mm or 100mm wire reel in the
machine.
Attach the reel with a reel lock.
Unfasten the wire end from the reel, but hold on it all the time.
Straighten the wire end for approximately 30 cm and cut the wire in the straightened location.
Open the pressure control level which then opens the feed gear.
Thread the wire through the wire’s rear guide to the gun’s wire guide.
Close the feed gear and fasten it with the pressure control lever. Make sure that the wire runs in
the feed roll groove.
Adjust the compression pressure with the pressure control lever no higher than to the middle of
the scale. If the pressure is too high, it removes metal fragments from the wire surface and may
damage the wire. On the other hand, if the pressure is too low, the feed gear slips and the wire
does not run smoothly.
Press the welding gun trigger and wait for the wire to come out.
Close the reel housing cover.
Note
:
When driving the wire into the gun, do not point the gun at yourself or others.