2.2.2   Mode Menu 

 The following figure shows the menu related to the different modes of system operation. 
 

 

 
 
 

 

 

Mode - Automatic

: this mode operates as follows:

 

 

Type 

Power on 

Filter 

Power off 

Filter 

End of charge 

Seal Pb  

12,2V 

For 3 min  14,2V 

or 

charge 

current <6A 

For 3 min 

After 5 min 

Free acid Pb  

12,2V 

For 3 min  14,8V 

or 

charge 

current <6A 

For 3 min 

After 5 min 

Lithium 

12,8V 

For 1 min  14,2V 

or 

charge 

current <3A 

For 1 min 

After 1 min 

In case of 24V batteries turn on and turn off voltages will be doubled 

 

 

Mode 

– Manual:

 this mode operates as follows: 

Power on

:  

o

  Pressing the icon 

 in Home Menu 

Power off

o

  Same as automatic mode or pressing  

 

 

Battery  -  Automatic: 

in  this  case  the

 

priority  is  given  to  the  charge  of  the  primary 

battery (services) with respect to the secondary one (engine). Nevertheless, the latter 
is  constantly  monitored  and  if  its  voltage  falls  below  a  minimum  value  it  will  be 

immediately charged 

 

 

Battery 

– Engine Battery: 

forcing engine battery charging; 

to be used only in case 

of emergency, when the vehicle battery is too low

. By activating this function all the 

energy produced (over 250W) will be sent to the secondary battery (engine) in order to 

quickly  recharge  it.  This  function  is  automatically  excluded  after  6  hours  or  when  the 
battery  is  fully  charged.  Once  the  secondary  battery  has  been  recharged,  the  system 
automatically switches to the primary battery (services). 

Note:

  I

n this mode the energy required for ignition and operation is taken from the primary 

battery. Before selecting this function, make sure that the primary battery is fully charged. 

 
 
 

Back to Settings Menu 

 

Automatic Mode 

 

Manual Mode 

 

Battery 
automatic 
selecion 

 

Engine 
battery 
forcing

 

Summary of Contents for ZEUS200 BD

Page 1: ...r USER MANUAL ZEUS200 BD Power Supply Diesel IMPORTANT You can obtain the 3 three year warranty extension by registering the product for free on support mobiltech it More information can be found in c...

Page 2: ...ble of charging the batteries of your boat regardless of the availability of external electricity or weather conditions Installation and commissioning must be performed by specialized personnel only u...

Page 3: ...rking The operation is very harmful because the cooling of the device will be lost causing possible breakages due to overheating Any incorrect operation is recorded in the device memory General notes...

Page 4: ...ash the generator using a pressure washer The generator is not designed to work submerged in water or other liquids in the event of flooding the warranty becomes void and it is necessary to go to an a...

Page 5: ...the menu structure is shown HOME SETTINGS TIMER MODE LANGUAGE SERVICE GENERATOR CONTROL UNIT Timer 1 Timer 2 Clock Automatic Manual Battery automatic selection Engine battery forcing Italian English...

Page 6: ...Manual mode generator not active The solar panel icon will be on only if the solar panel is charging The blue arrows with a continuous line indicate which of the energy sources is in operation and wh...

Page 7: ...ntly both graphically and numerically 2 1 2 Thermoelectric generator management Pressing the generator icon the screen display the Menu related to the energy supplied by the thermoelectric generator T...

Page 8: ...e to charge 12V and 24V secondary batteries The battery data is displayed on the left Type Actual voltage The percentage of engine battery charge is displayed on the right side of the screen Battery d...

Page 9: ...wo available Timers as well as the internal clock To set a timer press the related time and make the desired adjustments in the central part of the screen When the two timers are activated the related...

Page 10: ...the primary battery services with respect to the secondary one engine Nevertheless the latter is constantly monitored and if its voltage falls below a minimum value it will be immediately charged Bat...

Page 11: ...ers Software update The two icons at the bottom right display the status of communications between the different components of the system C communication between the display unit and the power unit G...

Page 12: ...ve on three different colors Gray working element actually not active Blue working element actually active Red failed element error issued In case of error it can be reset by pressing the relative ico...

Page 13: ...service battery in a more ventilated place Display shows Engine batt low Low voltage of engine battery Turn on the generator and force the charge on the engine battery Switch on vehicle s engine if p...

Page 14: ...let probe error Fault or lack of connection with outlet water probe Contact an authorized center for verification Display shows Water inlet probe error Fault or lack of connection with inlet water pro...

Page 15: ...sidering the fact that the generator produces energy based on the thermal delta the production of energy varies according to the sea temperature In addition the system can be affected by other factors...

Page 16: ...ch it Mail info mobiltech it service mobiltech it Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of oper...