TOOLCRAFT TO-7159158 Operating Instructions Manual Download Page 3

Installation

 NOTE

•  Observe the direction of flow (arrow marking on the port) indicating the outlet port.
•  Do not adjust the pressure switch without professional assistance.
•  Always disconnect the power supply when installing or servicing electrical parts.

a) Materials

  Some of the following items may be re-

quired for installation but not included.

•  2x (at least) pieces of flexible, reinforced hose 

piping, with collapsing strength of twice the inlet 

port collapsing pressure. Hose must be minimum 

19 mm (3/4”) inner diameter

•  4x stainless steel hose clamps and screws
•  4x screws to fasten the pump to the mounting 

surface

•  1x electrical cutoff switch
•  1x fuse
•  1x screwdriver
•  1x strong cutting implement for tubing
•  Teflon tape or sealant

b) Installation notes

•  The pump can be mounted in any position.

If mounted vertically, the pump head should be in 

the down position to avoid leakage into the motor 

casing if there is a malfunction.

•  Secure the feet, but do not compress them.

Overtightening the securing screws may reduce 

their ability to dissipate noise and vibration.

•  Inlet  hose  must  be  minimum  ø19  mm  (inner)

diameter reinforced hose. Main distribution line 

from pump outlet should also be ø19 mm (inner)

diameter with branch and individual supply lines 

to outlets no smaller than ø10 mm (inner).

•  Plumb the system using high pressure (2x pump 

rating), braided, flexible tubing to minimize vibra-

tion/ noise.

•  Do not apply inlet pressure >2 bar. It is recom-

mended to avoid inlet pressure.

•  Avoid kinks or fittings which can cause excessive 

restrictions.

•  The filter should be attached to the inlet side.
•  The fittings must be secured to avoid leakage.
•  Use clamps at both ends of hose to prevent air 

leaks into the water line.

•  If  a  check  valve  is  installed  in  the  plumbing,  it 

must have a cracking pressure ≤ 0.14 bar.

•  Wire the pump on its own dedicated circuit.

 - Red wire (+) connect to battery (+).
 - Black wire (-) connect to battery (-).

•  Install in an easy to access location with a switch 

to control electricity to the pump.

•  Switch the pump off when not used for extended 

periods or when the tank is empty.

•  The electrical circuit should be protected with an 

over-current protection device (e.g. fuse) along  

the positive lead. 

•  The  pump  circuit  should  not  include  any  other 

electrical loads.

•  Use the correct wire size for the length required.  

See “c) Wiring information”. 

•  After installation, check the voltage is correct:

 - Check the voltage at the motor.
 - Voltage should be checked when the pump is 

operating. 

 - Full  voltage  must  be  available  at  the  pump 

motor at all times

•  If using rigid piping, attach a short length of hose 

between the pipe and the pump to avoid noise 

and vibration.

•  It is not recommended to use metal fittings. Use 

the provided plastic fittings if possible.

c) Wiring information

Observe the recommended lengths to wire size.

Length (meters)

Ø

 

mm

2

 (AWG)

0 - 6

2,50 (14)

6 - 9

4,00 (12)

9 - 19

5,50 (10)

19 - 30

8,50 (8)

Pressure switch and bypass adjustment

 NOTE

•  Consult a professional technician if the bypass or pressure switch needs to be adjusted.
•  Improper adjustment may damage the pump.

•  The factory default settings are configured for optimal operation of the pump.
•  If an application requires different settings:

 - Rotate screw clockwise: increase pressure
 - Rotate screw counter-clockwise: decrease pressure. 

  If the pressure on the bypass is too high, it will effectively be dectivated. If the pressure is too low 

relative to the cut-off pressure of the pressure switch, it will not allow the pump to turn off.

Maintenance and storage

•  Regularly inspect electrical wiring and connections.
•  Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as they can 

cause damage to the housing and malfunctioning.

•  Before storage, especially before cold weather (winter), it is important to prepare the pump:

 - Disconnect, drain, and store the pump where it will not freeze. 
 - Open all the ports to allow air into the pump so the water can drain out.

 Operating Instructions

Low-Voltage Pressurized Water Pump 12 V, 1020 l/h 

Item No. 2386386

Intended use

The product is a professional grade self-priming 4-chamber diaphram pump. It has an automatic pressure 

switch that will automatically start/stop the pump when a tap or valve is opened/closed, and a bypass to help 

reduce short cycling. Only for use with fresh water or salt water.
Some applications include 
•  Yacht, caravan pressurized water system.
•  Sprayer fixtures (vehicle mounted, electric).
•  Cleaning machines, humumidifier, water purification.
•  Food beverage filling and liquid tansfer.
•  Solar water systems

 NOTE

•  The product is not suitable for outdoor use.
•  The product is not submersible.
•  The product has an ingress protection rating of IPX5. It can resist a sustained, low-pressure water 

jet spray.

•  Please read the included safety instructions.

For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product 

for purposes other than those described above, the product may be damaged. In addition, improper use can 

result in short circuits, fires, or other hazards. Read the instructions carefully and store them in a safe place. 

Make this product available to third parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company names and prod-

uct names are trademarks of their respective owners. All rights reserved.

Delivery contents

•  Pump
•  3x fittings

•  Filter
•  Operating instructions

Up-to-date operating instructions

Download the latest operating instructions at www.conrad.com/downloads or scan the 

QR code shown. Follow the instructions on the website.

Explanation of symbols

 

The symbol with the exclamation mark in 

the triangle is used to indicate important 

information  in  these  operating  instruc-

tions. Always read this information care-

fully.

  This product is constructed according to 

protection class III.

  Not  for  use  where  flammable  vapours 

are present.

  The arrow symbol indicates special in-

formation and advice on operation.

Safety instructions

Read the operating instructions 

carefully and especially observe 

the safety information. If you do not 

follow the safety instructions and 

information on proper handling in 

this manual, we assume no liability 

for any resulting personal injury or 

damage to property. Such cases will 

invalidate the warranty/guarantee.

a) General information

•  The device is not a toy. Keep it out of the reach 

of children and pets.

•  Do  not  leave  packaging  material  lying  around 

carelessly. This may become dangerous playing 

material for children.

•  Protect  the  appliance  from  extreme  tempera-

tures, strong jolts, flammable gases, steam and 

solvents.

•  Do not place the product under any mechanical 

stress.

•  If it is no longer possible to operate the product 

safely, take it out of operation and protect it from 

any accidental use. Safe operation can no longer 

be guaranteed if the product:

 - is visibly damaged,
 - is no longer working properly,
 - has been stored for extended periods in poor 

ambient conditions or

 - has been subjected to any serious transport-

related stresses.

•  Please  handle  the  product  carefully.  Jolts,  im-

pacts or a fall even from a low height can dam-

age the product.

•  Consult an expert when in doubt about the op-

eration, safety or connection of the appliance.

•  Maintenance,  modifications  and  repairs  must 

only be completed by a technician or an author-

ised repair centre.

•  If you have questions which remain unanswered 

by these operating instructions, contact our tech-

nical support service or other technical person-

nel.

b) Connected devices

•  Also  observe  the  safety  and  operating  instruc-

tions of any other devices which are connected 

to the product.

c) Product

 WARNING!

•  Do not use the pump for petrol/gasonline, petro-

leum products, solvents, thinners or ANY other 

flammable liquid.

•  Not for use where flammable vapours are pre-

sent.

Summary of Contents for TO-7159158

Page 1: ... der Druck im Verhältnis zum Abschaltdruck des Druckschalters zu niedrig eingestellt schaltet sich die Pumpe nicht automatisch aus Wartung und Lagerung Überprüfen Sie regelmäßig die elektrischen Leitungen und Anschlüsse Verwenden Sie keine aggressiven Reinigungsmittel Alkohol oder andere chemische Lösungsmittel da diese zu Schäden am Gehäuse und zu Fehlfunktionen führen können Vor der Einlagerung ...

Page 2: ...eitungs druck ist gering Vergewissern Sie sich dass an der Einlassöffnung der Pumpe keine Luft eindringt Stellen Sie sicher dass sich kein Schmutz im Inneren der Pumpe oder im Gehäuse angesammelt hat Überprüfen Sie das Pumpenlager auf Verschleiß und laute Betriebsgeräusche Überprüfen Sie die Membran der Pumpe auf Beschädigungen Überprüfen Sie den Motor auf Beschädigungen Das Betriebsge räusch der ...

Page 3: ...d store the pump where it will not freeze Open all the ports to allow air into the pump so the water can drain out Operating Instructions Low Voltage Pressurized Water Pump 12 V 1020 l h Item No 2386386 Intended use The product is a professional grade self priming 4 chamber diaphram pump It has an automatic pressure switch that will automatically start stop the pump when a tap or valve is opened c...

Page 4: ...sposal Electronic devices are recyclable waste and must not be disposed of in the household waste At the end of its service life dispose of the product in accordance with applicable regulatory guidelines You thus fulfill your statutory obligations and contribute to the protection of the envi ronment Technical data Input voltage current 12 V DC 15 A Fuse 30 A Protection class III Ingress protection...

Page 5: ...hiver il est important de préparer la pompe Débranchez vidangez et rangez la pompe dans un endroit à l abri du gel Ouvrez tous les orifices pour permettre à l air d entrer dans la pompe et à l eau de s écouler Mode d emploi Pompe à eau pressurisée basse tension 12 V 1 020 l h N de commande 2386386 Utilisation prévue Ce produit est une pompe à diaphragme à 4 chambres auto amorçante de qualité profe...

Page 6: ...uyau rigide elle peut transmettre du bruit Élimination des déchets Les appareils électroniques sont des matériaux recyclables et ne doivent pas être éliminés avec les ordures ménagères En fin de vie éliminez l appareil conformément aux dispositions légales en vigueur Ainsi vous respectez les ordonnances légales et contribuez à la protection de l en vironnement Caractéristiques techniques Tension c...

Page 7: ...oor koud weer winter is het belangrijk om de pomp voor te bereiden Koppel de pomp los laat het leeglopen en berg het op waar het niet kan bevriezen Open alle poorten om lucht in de pomp te laten lopen zodat het water kan weglopen Gebruiksaanwijzing Laagspanning drukwaterpomp 12 V 1020 l u Bestelnr 2386386 Beoogd gebruik Het product is een zelfaanzuigende membraanpomp met 4 kamers van professionele...

Page 8: ...dan kan deze lawaai over brengen Verwijdering Elektronische apparaten zijn recyclebaar afval en horen niet bij het huisvuil Als het product niet meer werkt moet u het volgens de geldende wettelijke bepalingen voor afvalverwerking afvoe ren Op deze wijze voldoet u aan uw wettelijke verplichtingen en draagt u bij aan de bescherming van het milieu Technische gegevens Ingangsspanning stroom 12 V DC 15...

Reviews: