45
10.5 Area of application
When using the generator, ensure that the total load is within the rated output power of the generator. Failure to do so
may cause damage to the generator.
AC
Power factor
1
0.8 - 0.95
0.4 - 0.75
(Efficiency 0.85)
Rated power
≤ 1700 W
≤ 1360 W
≤ 544 W
Nominal volt-
age: 12 V
Rated current: 8 A
TIP:
The wattage of a device indicates the individual power of a device when used.
The simultaneous use of AC and DC current is possible, but the total wattage of
the rated power must not be exceeded.
1
Example:
Nominal output power of the generator
1700 W
Frequency
Power factor
1.0
≤ 1700 W
AC
0.8
≤ 1360 W
DC
---
96 W (12 V / 8 A)
The overload indicator (3) lights up when the total wattage exceeds the generator’s range. (See page 10 for more
information.)
(IMPORTANT)
Do not overload the generator. The total load of all electrical devices/appliances must not exceed the generator’s
supply range. Overloading will damage the generator.
When connecting precision devices, electronic controls, PCs, computers, microcomputer equipment or battery
chargers, keep the generator at a distance to prevent electrical interference with the engine. In addition, make sure
that electrical noise from the engine does not interfere with other electrical devices located near the generator.
Before connecting the generator to medical equipment, seek advice from the manufacturer, a doctor or hospital.
Some electrical appliances or universal electric motors have high inrush currents and therefore cannot be used,
even if they are within the designated range as indicated in the table above. Contact the device manufacturer for
more details.