TOOLCRAFT 2386376 Operating Instructions Manual Download Page 4

c) Connection

• 

Connect a non-kink hose to the outlet nozzle and clamp using a marine grade stainless-

steel clamp.

• 

Use the correct hose size. Using a hose with smaller diameter will not damage the pump 

but will restrict flow.

Installation tips

  See figure 1.

• 

The hull should be ≥13 mm (1/2”) thick. 

 -

If needed place a block of marine plywood (slightly larger than the pump base) in the 

lowest part of the bilge.

 -

Glue the plywood to the hull with a suitable waterproof marine grade adhesive. 

• 

Position the pump in the lowest part of the bilge on a flat, level surface (on the plywood 

block if it has been installed) with the outlet pointing toward the transom.

 -

Make sure outlet nozzle is level. If pointed upward or downward, an airlock may form in 

the pump.

• 

The float end of the pump must be level with or above the pump end. 

 -

This prevents the pump from running out of water while the float is still high enough to 

activate the pump.

 IMPORTANT! 

When drilling holes do not drill through the hull!

• 

Use marine grade stainless steel clamps to secure the hose.

• 

Route the hose on an upward incline to the thru-hull fitting.

 -

Avoid dips in hose that can trap water and air in the pump.

 -

Avoid putting excess tension on hose, which can damage the pump outlet.

Wiring

  See figure 2.

 IMPORTANT!

• 

The power supply must not exceed 12 V/DC. Higher voltages will damage the pump.

• 

All wires and connections must be above the bilge water level. 

• 

To prevent electrolysis and corroded wire connections, all wire ends and terminals 

should be sealed with heavy duty marine sealant and located above the highest pos

-

sible water level by fastening with insulated staples or plastic straps.

• 

Always install the correct fuse type and specification. Failure to do so can cause 

pump malfunction and result in personal injury and / or fire hazard.

• 

Always disconnect the power supply when installing or servicing electrical parts.

• 

Use ø1.02 mm (18 AWG) wire. Lower guages can cause overheating and reduce 

the pumps performance.

1.  Connect wires to the pump as shown in the diagram. Use the full length of wire provided 

(use additional wire if needed).

Automatic

 

 -

Connect brown-white wire connect to battery (+) terminal.

 -

Connect black wire connected to battery (-).

Manual

 -

Conect brown wire connect to battery (+) terminal.

 -

Connect black wire connecte to battery (-).

2.  Route wires out of the way and secure them to the bulkhead to avoid pulling.
3.  Splice the fuse holder into the positive lead (brown), between the battery and switch.

 -

Position fuse holder in a location that is easily accessible for changing fuses.

 -

 

Use fuses of the proper amperage (see technical data).

4.  Install a three-way switch that allows for automatic or manual switching models.
5.  Turn the pump on and twist the 

TURN TO TEST

 knob clockwise to check operation.

6.  Feed water into the pump. If output appears to be too low, check for reversed wire connec

-

tions. Reversed connections can result in opposite impeller rotation that drastically reduces 

capacity and can cause premature pump failure.

Operation

 IMPORTANT!

• 

Only use with fresh water or salt water.

• 

DO NOT use with gasoline, diesel, oil, hazardous, caustic, corrosive, or other flam

-

mable liquids.

• 

Do not dry run the pump.

a) Automatic pumping

1.  When the water level rises the float switch’s contact point is connected and the pump is 

activated.

2.  When the water level drops, the float switch’s contact point is disconnected, and the pump 

is deactivated.

b) Manual pumping

Pumping is activated/deactivated using a 3-way switch.

Care and maintenance

 IMPORTANT!

• 

Never disconnect the filter while the pump is running.

• 

Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solu

-

tions as they can cause damage to the housing and malfunctioning.

• 

Regularly inspect electrical wiring and connections.

• 

Regularly check that debris is not jamming the impeller and/or float within the housing. Twist 

the 

TURN TO TEST

 knob clockwise to check operation.

• 

Remove debris that has accumulated in pump chamber and impeller.

 -

Clean the water chamber: remove the pump housing from the filter basket.

 -

Clean the impeller: remove the pump housing from the filter basket, then remove the 

impeller guard screws

• 

Check the impeller is firmly attached to shaft and is not cracked or broken.

Disposal

  Electronic devices are recyclable waste and must not be disposed of in the house

-

hold waste. At the end of its service life, dispose of the product in accordance with 

applicable regulatory guidelines. You thus fulfill your statutory obligations and con

-

tribute to the protection of the environment.

Technical data

Input voltage / current ................... 12 V/DC, 3 A
Fuse .............................................. 5.0 A
Protection class ............................

III

Ignition protected .......................... yes
Fluid medium ................................ fresh water, salt water
Ingress protection ......................... IPX8
Discharge head ............................ max. 3 m
Immersion depth ........................... max. 2 m
Wire lead ...................................... 1 m
Flow rate ....................................... max. 2839 l/h
Grain size ..................................... max. 3.3 mm
Hose connection ........................... ø19 mm (3/4”)
Operating/Storage temp. ..............  0 to +40 ºC
Dimensions (W x H x D) ............... 83 x 103 x 145 mm
Weight .......................................... 470 g

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in

-

cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication 

represent the technical status at the time of printing.
Copyright 2021 by Conrad Electronic SE. 

  

 

*2386376_v2_1121_02_dh_mh_en

Summary of Contents for 2386376

Page 1: ...sehen Lesen Sie sich die in dieser Bedienungsanleitung enthaltenen Sicherheitshinweise sorg fältig durch Aus Sicherheits und Zulassungsgründen dürfen Sie das Produkt nicht umbauen und oder ver ändern Sollten Sie das Produkt für andere als die zuvor beschriebenen Zwecke verwenden kann das Produkt beschädigt werden Darüber hinaus kann eine ungeeignete Benutzung Kurz schlüsse Brände oder andere Gefah...

Page 2: ...gegen ein ungewolltes Abziehen geschützt sind 3 Bringen Sie die Halterung der Sicherung an der positiven Leitung braun zwischen der Batterie und dem Schalter an Beachten Sie dass die für die Halterung gewählte Stelle für den Fall dass die Sicherung durch eine neue ersetzt werden muss leicht zugänglich sein sollte Verwenden Sie ausschließlich Sicherungen die für die entsprechende Stromstärke A ausg...

Page 3: ...hem in a safe place Make this product available to third parties only together with its operating instructions This product complies with the statutory national and European requirements All company names and product names are trademarks of their respective owners All rights reserved Delivery content Product Operating instructions Up to date operating instructions Download the latest operating ins...

Page 4: ...ll a three way switch that allows for automatic or manual switching models 5 Turn the pump on and twist the TURN TO TEST knob clockwise to check operation 6 Feed water into the pump If output appears to be too low check for reversed wire connec tions Reversed connections can result in opposite impeller rotation that drastically reduces capacity and can cause premature pump failure Operation IMPORT...

Page 5: ...ez attentivement les instructions du mode d emploi et conservez le dans un endroit sûr Ne mettez ce produit à la disposition de tiers qu avec son mode d emploi Ce produit est conforme aux exigences nationales et européennes en vigueur Tous les noms d entreprises et appellations de produits sont des marques commerciales de leurs propriétaires respectifs Tous droits réservés Contenu de l emballage P...

Page 6: ...pproprié reportez vous aux caractéristiques techniques 4 Installez un interrupteur à trois voies permettant le passage en mode automatique ou ma nuel 5 Mettez la pompe en marche et tournez le bouton TURN TO TEST dans le sens des aiguilles d une montre pour vous assurer qu elle fonctionne correctement 6 Remplissez la pompe avec de l eau Si le débit semble trop faible vérifiez si les connexions des ...

Page 7: ...een veilige plek Het product mag alleen samen met de gebruiksaanwijzing aan derden worden doorgegeven Het product is voldoet aan de nationale en Europese wettelijke voorschriften Alle bedrijfs en productnamen zijn handelsmerken van de betreffende eigenaren Alle rechten voorbehouden Leveringsomvang Product Gebruiksaanwijzing Meest recente gebruiksaanwijzing Download de meest recente gebruiksaanwijz...

Page 8: ...zekeringen van de juiste stroomsterkte zie technische gegevens 4 Installeer een driestandenschakelaar voor automatische of handmatige schakelmodellen 5 Schakel de pomp in en draai de knop TURN TO TEST rechtsom om de correcte werking te controleren 6 Laat de pomp met water vullen Als de afvoer te zwak lijkt controleer dan op omgekeerde draadaansluitingen Omgekeerde aansluitingen kunnen de waaier in...

Reviews: