OPERATION

Fig. 8

COIL HOSE WITH QUICK 
COUPLER ATTACHED

PNEUMATIC 

TOOL 

(not included)

MALE QUICK-

CONNECT PLUG

   WARNING:

Always wear safety goggles or safety glasses with 
side shields when operating power tools. Failure to do 
so could result in objects being thrown into your eyes 
resulting in possible serious injury.

   WARNING:

Do not allow familiarity with tools to make you careless. 
Remember that a careless fraction of a second is 
sufficient to inflict serious injury.

CAUTION:

Do not use in an environment that is dusty or otherwise 
contaminated. Using the air compressor in this type of 
environment may cause damage to the unit.

   WARNING:

Always ensure the switch is in the 

OFF (O)

 position and the 

regulator pressure gauge reads zero before changing air 
tools or disconnecting the hose from the air outlet. Failure 
to do so could result in possible serious personal injury.

APPLICATIONS

Air  compressors  are  utilized  in  a  variety  of  air  system 
applications.  Match  hoses,  connectors,  air  tools,  and 
accessories to the capabilities of the air compressor.

You may use this tool for purposes listed below:

  Operating some air-powered tools.
  Inflating tires, air beds, sports equipment, etc.

USING THE AIR COMPRESSOR

See Figure 7 - 8.

  Ensure tank drain valve is closed (see Fig. 7).
  Ensure ON/OFF power switch is in the 

OFF

 

(O)

 position 

and air compressor is unplugged (see Fig. 7).

  Ensure Pressure Regulator Knob is turned fully 

counterclockwise (see Fig. 7).

  If not already installed, attach hose to compressor.
  Connect air powered tools to air hose by inserting the 

male quick-connect plug to the quick-coupler at the end 
of the coil hose (see Fig. 8).

  Connect the power cord to the power supply.
  Turn the switch 

ON (I)

.

  Rotate pressure regulator knob to desired line 

pressure. Turning the knob clockwise increases 
air pressure at the outlet; turning counterclockwise 
reduces air pressure at the outlet.

 

NOTE:

 Before connecting or disconnecting air tools turn 

the regulator knob counter-clockwise to stop the flow of air.

  Following all safety precautions in this manual and the 

manufacturer’s instructions in the air tool manual, you 
may now proceed to use your air-powered tool.

  If using an inflation accessory with a quick-connect 

fitting, control the amount of air flow with the pressure 
regulator knob. Turning the knob fully counter-clockwise 
will completely stop the flow of air.

 

NOTE:

 Always use the minimum amount of pressure 

necessary for your application. Using a higher pressure 
than needed will drain air from the tank more rapidly 
and cause the unit to cycle on more frequently.

  When finished, always drain the tank and unplug the unit. 

Never leave the unit plugged in and/or running unattended.

   WARNING:

Check  the  air  tool  manual  to  insure  the  correct  air  pressure 
regulator setting for optimum operation of your air tools. If you 
are using an air tool not originally included with the air tool kit 
supplied with this air compressor, your tool may require more air 
consumption than this air compressor is designed to supply.
Always read your air tool owner’s manual to match the correct 
air supply to your air tool to avoid damage to the tool or risk of 
personal injury.

ON/OFF 
POWER 

SWITCH

PRESSURE 

REGULATOR 

KNOB

DRAIN

 VALVE

Fig. 7

Summary of Contents for TS11OL227

Page 1: ...4 7 CUSTOMER SERVICE 1 866 242 4298 Thank you for buying a Tool Shop product Your air compressor has been engineered and manufactured to Tool Shop s high standard for dependability ease of operation and operator safety When properly cared for it will give you years of rugged trouble free performance ...

Page 2: ...sibility to drain oil lubed units prior to shipment to meet ICC state and local fire regulations Please have your model number and serial number available These can be found on the data label on your product Retain a copy of your receipt with purchase date for reference NOTICE 8 0 3 328 287 2863 9 8 32 2 6 35 2 This tool has many features for making its use more pleasant and enjoyable Safety perfo...

Page 3: ...n will be required in some environments For example the working area may include exposure to a noise level which can lead to hearing damage The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When required the employer and user must ensure that he...

Page 4: ... qualified repair personnel Service or maintenance performed by unqualified personnel may result in a risk of injury GENERAL SAFETY RULES Disconnect power supply open drain valve to decompress tank and allow water to drain and allow air compressor to become cool to the touch before servicing Turn pressure regulator knob fully counter clockwise after shutting off compressor When servicing a tool us...

Page 5: ...ys follow all safety rules recommended by the manufacturer of your tool in addition to all safety rules for the air compressor Following this rule will reduce the risk of serious personal injury Never direct a jet of compressed air toward people or animals Take care not to blow dust and dirt towards yourself or others Following this rule will reduce the risk of serious injury Protect your lungs We...

Page 6: ...6 Do not adjust the regulator to result in output pressure greater than the marked maximum pressure of the attachment Do not use at a pressure greater than the rated maximum pressure of this compressor ...

Page 7: ... WLMIPHW SV E JYPP JEGI WLMIPH LIR RIIHIH I VIGSQQIRH MHI MWMSR 7EJIX 1EWO JSV YWI SZIV I IKPEWWIW SV WXERHEVH WEJIX KPEWWIW MXL WMHI WLMIPHW P E W YWI I I TVSXIGXMSR LMGL MW QEVOIH XS GSQTP MXL 27 62 2 7 8 7 27869 8 327 8LI JSPPS MRK WMKREP SVHW ERH QIERMRKW EVI MRXIRHIH XS I TPEMR XLI PIZIPW SJ VMWO EWWSGMEXIH MXL XLMW TVSHYGX 7 1 30 7 2 0 1 2 2 2 6 62 2 98 32 98 32 RHMGEXIW ER MQQMRIRXP LE EVHS...

Page 8: ...e plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances Do not modify the plug provided If it will not fit the outlet have the proper outlet installed by a qualified electrician The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If rep...

Page 9: ...andard Cubic Feet Per Minute A unit of measure of air delivery L min Liter Per Minute A unit of measure of air delivery Tank Pressure Gauge Indicates the pressure in the air tank Thermal Overload Switch Automatically shuts off the compressor if the temperature of the electric motor exceeds a predetermined limit ...

Page 10: ...M 90 PSI 4 2 SCFM 40 PSI Lubrication Oil Free Gauges one gauge 1 5 in one gauge 2 0 in diameter Input 120 V 60 Hz AC only 13 5 Amps Net Weight only compressor 49 6 lbs Fig 2 PRESSURE REGULATOR KNOB SAFETY VALVE HANDLE TANK WHEEL MANUAL ON OFF SWITCH QUICK COUPLER RUBBER FOOT REGULATOR PRESSURE GAUGE TANK PRESSURE GAUGE DRAIN VALVE ...

Page 11: ...ings PRESSURE REGULATOR KNOB Use the pressure regulator knob to adjust the amount of air being delivered through the hose REGULATOR PRESSURE GAUGE The current line pressure is displayed on the regulator pressure gauge This pressure can be adjusted by rotating the pressure regulator knob SAFETY VALVE The safety valve is designed to automatically release air if the air receiver pressure exceeds the ...

Page 12: ...secure it in position Rubber foot packing list Screw 8 mm 2 Washer 2 Rubber Foot 1 Nut 8 mm 2 Mount the wheels as shown in figure 3 Tighten firmly with an open end wrench not included to secure the wheels in position Wheel packing list Screw 10 mm 2 Wheel 2 Nut 10 mm 2 Wheel Plug 2 Fig 3 WHEEL SCREW 10mm NUT 8mm NUT 10mm SCREW 8mm WHEEL PLUG RUBBER FOOT WASHER ...

Page 13: ...urself and others BREAKING IN THE PUMP See Figure 4 5 Check and tighten all bolts fittings etc Turn the pressure regulator knob fully clockwise to open the air flow Place the switch in the OFF O position and plug in the power cord Open the drain valve completely Turn the air compress ON l and run the air compressor for 10 minutes to break in pump parts Place the switch in the OFF O position Close ...

Page 14: ... tools to air hose by inserting the male quick connect plug to the quick coupler at the end of the coil hose see Fig 8 Connect the power cord to the power supply Turn the switch ON I Rotate pressure regulator knob to desired line pressure Turning the knob clockwise increases air pressure at the outlet turning counterclockwise reduces air pressure at the outlet NOTE Before connecting or disconnecti...

Page 15: ...ss of air after releasing the safety valve ring indicates a problem with the safety valve Discontinue use and seek service before continued use of the air compressor OPERATION WARNING Unplug the air compressor and release all air from the tank before servicing Failure to depressurize tank before attempting to remove valve may cause serious personal injury WARNING Do not attempt to tamper with safe...

Page 16: ... sufficient amount of high grade lubricant for the life of the unit under normal operating conditions Therefore no further lubrication of the bearings is required WARNING Do not at any time let brake fluids gasoline petroleum based products penetrating oils etc come in contact with plastic parts Chemical can damage weaken or destroy plastic which may result in serious personal injury Electric tools...

Page 17: ... and cord length Take compressor to service center Thermal overload protector cuts out repeatedly Low voltage Lack of proper ventilation room temperature too high Wrong gauge wire or length of extension cord Check with voltmeter Move compressor to well ventilated area Check for proper gauge wire and cord length Air receiver pressure drops when compressors shuts off Loose connections fittings tubin...

Page 18: ...18 REPLACEMENT PARTS LIST PARTS DIAGRAM AIR COMPRESSOR ...

Page 19: ... 1 114 9011049 WHEEL PIN 2 117 9038408 RUBBER HANDLE 1 127 9270048 RILSAN PIPE 1 15 ft 131 9063200 PRESSURE SWITCH 1 132 9065680 CORD WITH PLUG 1 133 9414765 POWER SWITCH 1 145 9043345 SENDING PIPE 1 500 9038570 SEMIPLASTIC COVER LOWER 1 501 9064788 LOCK CABLE 1 502 9414744 GAUGE 1 503 9038402 WHEEL PLUG 2 504 9064815 WIRING 1 505 9050565 ELBOW 1 506 9050566 CONNECTOR STRAIGHT 1 507 9142803 SCREW ...

Page 20: ...20 REPLACEMENT PARTS LIST PARTS DIAGRAM PUMP UNIT ...

Page 21: ...5 BEARING 6203 2Z XL 1 041 C710300 CONROD COVER OL227 1 045 9140211 SEEGER 12 UNI 7435 ROHS 1 046 9038711 FAN OL227 UL 1 062 A650300 GASKET CYLINDER VALVE PLATE SP200 0 8MM 1 064 9415052 GASKET PLATE HEAD OL195SIL 1 078 9040019 SEAL SP200 1 126 9075316 BELT POLY V J4 373 1 600 9411228 SCREW TCEI 6X35 BRN 5931 129 4 601 9103284 SCREW TSEI 6X20 10 9 FST 5933 1 602 9101555 SCREW TCEI 5X16 LEFT R80 RO...

Page 22: ...ries to persons property or costs This warranty does give you specific legal rights and you may have other rights which vary from state to state Be careful tools are dangerous if improperly used or maintained Seller s employees are not qualified to advise you on the use of this Merchandise Any oral representation s made will not be binding on seller or its employees The rights under this limited w...

Page 23: ...23 NOTES ...

Page 24: ...OPERATOR S MANUAL TS11OL227 11 GALLON PORTABLE AIR COMPRESSOR CUSTOMER SERVICE 1 866 242 4298 ...