Tomar 4375 Installation, Operation And Maintenance Data Sheet Download Page 3

IS0802-00 
11-08-18 

 

Note: 1. Dip switches will override any external wire connections made. 
Note: 2. If the blue and yellow wires are not used cut off or cap with a wire nut. 

 
 

TABLE 2 

Internal Dip Switch Settings for setting modes of operation 

Switch 1 

Switch 2 

Mode 

On 

Off 

Single flash 2 380mS On, 380ms Off 

Off 

On 

Double flash @200mS On, @00mS On, 900mS Off 

On 

On 

Off 

Off 

Off 

Steady Burn PWM @ 66.4% 

External Wire Connections for setting modes of operation 

Yellow 

Blue

 

Mode 

Line 

Neutral

 

Single flash 2 380mS On, 380ms Off 

Neutral 

Line

 

Double flash @200mS On, @00mS On, 900mS Off 

Line 

Line

 

Off 

Neutral 

Neutral

 

Steady Burn PWM @ 66.4% 

Notes: yellow and blue wires can also be connected to PLC controller for mode 
activation.  For a PLC the input voltage can be either be AC or DC,  but must be greater 
than 10 volts RMS and no more than 24 volts RMS 

 

8.

 

Replace the LED light engine assembly and attach 2 screws. 

9.

 

Secure the dome to the base of the beacon. 

10.

 

Connect power to the beacon and test it for proper operation 

 

Summary of Contents for 4375

Page 1: ...ted below are some other important safety instructions and precaution you should follow Read and understand all instructions before installing or operating this equipment Do not connect this device to the system when the power is turned on After installation ensure that all screws and thread joints are properly tightened After installation test the system regularly to ensure that it is operating p...

Page 2: ... Neutral Single flash 2 380mS On 380ms Off Neutral Line Double flash 200mS On 00mS On 900mS Off Line Line Off Neutral Neutral Steady Burn PWM 66 4 Notes The yellow and blue wires can also be connected to PLC controller for mode activation For a PLC the input voltage can be either be AC or DC but must be greater than 100 volts RMS and no more than 240 volts RMS 8 Replace the LED light engine assemb...

Page 3: ...l Wire Connections for setting modes of operation Yellow Blue Mode Line Neutral Single flash 2 380mS On 380ms Off Neutral Line Double flash 200mS On 00mS On 900mS Off Line Line Off Neutral Neutral Steady Burn PWM 66 4 Notes yellow and blue wires can also be connected to PLC controller for mode activation For a PLC the input voltage can be either be AC or DC but must be greater than 10 volts RMS an...

Page 4: ...R DANGER HIGH VOLTAGE Should the light fail to operate check to see that the proper voltage is reaching the unit If the unit still fails to operate replace the light engine To replace a lens or light engine switch power off and wait 5 minutes before removing lens WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I DIVISION 2 WARNING EXPLOSION HAZARD DO NOT DISCON...

Reviews: