background image

EN
Recommended

1.     Branch pipe

2.     Main pipe approx. 1:100 Downward pitch away from the compressor

3.     Drain trap

4.     Shut-off valve

5.     Filter

6.     Regulator

7.     Oiler

8.     Coupling

9.     Air Hose (thick as poss)

10.   Air compressor

11.   Main pipe

 

Technical specifications

Brand

:  Toku

Safety standard

: EN ISO 11148-4

Shank size (mm)

:  H^19 x 50

Piston (mm)

:  24

Stroke (mm)

:  58

Strokes per minute

:  2800

Energy (J/Stroke)

:  12,7

Airconsumption (l/s)

:  7,5

Weight (kg)

:  4,5

Airconnection

:  PT 3/8"

Hosediameter (mm)

:  10

Vibration level (m/s²)

:  10

Sound level (dB(A))

:  93

mm A

:  300

mm B

:  76

Maximum Airpressure (Bar)

:  6,3

Before taking into use

Read and understand the contents of this manual before installing, operating, repairing, maintaining, changing accessories of this tool.

Only qualified and trained operators should install, adjust or use the tool.

Please fill some droplets of resin and acid free oil into the air inlet and let the tool run free for a couple of seconds. (E.g. Red Rooster
air tool oil: Order no. Atlub)

Before connecting the hose to the tool please check, whether the hose and the quick coupler are clean. Do this by letting air run freely
through hose and quick coupler, It is absolutely necessary, that quick coupler and hose have a sufficient diameter. Please note, that
the hose is never too big, but mostly too small!

Air pressure at the inlet of the tool during running has to be at the maximum of 6.3 bar. When this pressure is exceeded, unnecessary
wear and/or damage will occur. At the pressure of below 5.5 bar power loss will occur and if the pressure is excessively low, also
additional wear/damage will occur.

The quality of the compressed air must be good, which means clean, dry and this is best assured by means of an air filter. We advise
the use of a complete FRL (filter, regulator, lubricator) unit. The oiler has to be adjusted to approx. 3 to 6 droplets per minute. The air
hose between oiler and tool should never exceed a length of 6 to 8 meters.

In those cases, where it is possible, use of a centralized oiler is recommended by us. This system will allow use of less oil and assure a
perfect lubrication. When using a centralized oiler, oil consumption can be reduced by up to 80%.

If you intend not to use the tool for a longer period of time, it has to be oiled. Please fill some droplets of resin and acid free oil into the
air inlet and let the tool run free for a couple of seconds. 

Do not ignore safety precautions!

Safety

Do not modify this tool in any way, this can cause danger for the operator.

Make sure that this manual is accessible at all times for any relevant person, in case of loss of this manual ask your dealer for a new
copy or refer to our website.

Risk of explosion or fire: Make sure that generated sparks and/or increased temperature of the work piece can not cause any
explosion or ignite a fire.

Make sure that during operation of the tool no projectiles can be generated, this can be dangerous and may cause injuries.

Make sure that the work piece is securely fixed.

Make sure that the inserted tool or accessory is mounted correctly, if not it may cause high speed projectiles.

Make sure that no dangerous circumstances can occur for other persons in the work area.

Always wear safety glasses during operation of the tool. The grade of protection must be in relation to the risk of the operation.

Summary of Contents for AA-1.3BR(H)19X50

Page 1: ... AA 1 3BR H 19X50 MANUAL EN www rami yokota com ...

Page 2: ......

Page 3: ...tional wear damage will occur The quality of the compressed air must be good which means clean dry and this is best assured by means of an air filter We advise the use of a complete FRL filter regulator lubricator unit The oiler has to be adjusted to approx 3 to 6 droplets per minute The air hose between oiler and tool should never exceed a length of 6 to 8 meters In those cases where it is possib...

Page 4: ...e designed for it and are resistant against the used air pressure Always use safety quick change couplers Never let the tool run free in the air the accessory may come loose and become a projectile causing danger or injury Only use accessories that are in good condition worn accessories can be dangerous and cause injuries Only trained and qualified operators should use the tool Never use a damaged...

Page 5: ...rly for loose bolts screws or parts In case of power loss Have the tool repaired Only trained and qualified engineers are allowed to adjust or repair the tool In case the tool is equipped with a silencer make sure that this silencer is working properly a damaged silencer has to be replaced In case of disposal of the tool follow local regulations so as much as possible can be recycled Do not throw ...

Page 6: ...lare that this product is conform the European Directive 2006 42 EG and the standard EN ISO 11148 4 Technical file available from Rami Yokota BV RAMIYOKOTA BV De Ruyterkade 120 1011 AB Amsterdam THE NETHERLANDS Date 09 03 2020 Place Amsterdam Signature N Nauta Managing Director RAMIYOKOTA BV ...

Page 7: ... www rami yokota com ...

Reviews: