Tohnichi DATA TORK CEM3-G-WF Operating Instructions Manual Download Page 31

30 

 

11.2. Setting procedure by key operation

 

Set the counter to “000” using 

  keys 

 

i.  Measurement mode setting 

 

 

ii.  Display mode setting 

 

 

iii.  Unit of torque 

 

 

 

 

 

 

Press and hold 

  more than 2 seconds to 

get in setting mode 

 

 

 

 

Select the measurement mode using

 

   

“MODE-T”: Tightening mode 

“MODE-M”: Inspection mode 

 

Press 

  to save setting and go to next 

Press 

  to skip setting and go to next 

Press 

  to return to Measurement mode 

 

 

 

 

Select the display mode using

 

 

“MEMCNT”: Memory counter display mode 

“TORQUE”: High/ Low limit display mode 

 

Press 

  to save setting and go to next 

Press 

  to skip setting and go to next 

Press 

  to return to Measurement mode 

 

 

 

Select the unit of measurement using 

 

 

Press 

  to save setting and go to next 

Press 

  to skip setting and go to next 

Press 

  to return to Measurement mode 

Summary of Contents for DATA TORK CEM3-G-WF

Page 1: ...Wireless Digital Torque Wrench DATA TORK MODEL CEM3 G Operating Instruction CEM100N3X15D G WF...

Page 2: ...er source Doing otherwise may cause abnormal generation of heat which may result in fire Do not charge the battery in conditions outside of the 0 40 degree Celsius temperature range Doing so may cause...

Page 3: ...or sockets may cause accidents injuries and or product failures 1 Always keep the workplace clean and uncluttered Untidy place or work stand may lead to accidents 2 Keep away from children Do not let...

Page 4: ...truction manuals Doing otherwise may cause injuries Check the cable of the charger periodically and contact the nearest distributor or Tohnichi for repair Doing otherwise may cause an electric shock a...

Page 5: ...y specified in this manual 9 Make sure to conduct daily inspection as well as periodic inspection 10 Push clear and make sure the display shows zero zero adjustment before measuring 11 For accurate me...

Page 6: ...tion 21 9 1 Checking the measured data 21 9 2 Data processing function 22 9 3 Batch output of measurement data 23 9 4 Data clearance 24 10 External output format 25 10 1 Wireless LAN communication spe...

Page 7: ...6 16 Specifications 47...

Page 8: ...ne tool would can work for multiple fasteners without tool changing That saves time to change the tool costs for installation and tool managing It is ideal for cell lot productions and small lot produ...

Page 9: ...OK and red LED turns on for NG 6 Power button Switch to poser on and off When power is on does zero check on torque measurement Press and hold it for 2 seconds to turn off wireless LAN module power 7...

Page 10: ...kwise thread 15 Charge jack Connect BC 3 G charge to this jack for charging 16 External output terminal Terminal to connect RS232C cable or USB cable to transfer data 17 Reset button Press it when dis...

Page 11: ...r is on to turn off all power Wireless LAN communication status LED Blue LED blinks when tool connects with access point solid blue LED turn on when tool connect with PC or server via access point Bli...

Page 12: ...l gives beep continuous and solid blue LED to tell tightening completion The Hi Lo torque values can be set through wireless LAN 5 2 Display mode Default MEMCNT RUN mode The counter is 000 The display...

Page 13: ...operates normally If not contact TOHNICHI or the nearest distributor to ask for repair 6 3 Auto memory reset After tightening or measuring the values are automatically saved and forward to the counte...

Page 14: ...condition loading torque is less than 7 5 of the max torque range of the model the power will automatically turn off If you prefer not to use Auto power off set it to OFF At LoBATT alarm condition po...

Page 15: ...ue Min Max 105 of Max capacity torque 7 5 of Max capacity torque CEM10N3X8D G WF 2 00 10 00 0 01 10 50 0 75 0 75 CEM20N3X10D G WF 4 00 20 00 0 02 21 00 1 50 1 50 CEM50N3X12D G WF 10 00 50 00 0 05 52 5...

Page 16: ...torque and timestamp If there is wireless LAN connection on the tool it outputs them NOTE The time of timestamp is at the key pressed If there is Auto memory reset setting the data are stored output...

Page 17: ...bility iv When press key after measurement tool judges the result If there is Auto memory reset setting the judgment will be performed automatically When judgment is OK Shows the solid blue LED for ab...

Page 18: ...res from about 7 5 of torque capability iv When press key after measurement tool judges the result If there is Auto memory reset setting the judgment will be performed automatically When judgment is O...

Page 19: ...mit to 50 Nm for low limit for example iii Make sure the LCD left side display shows counter between 001 to 999 then measure NOTE Display can captures from about 7 5 of torque capability iv The tool g...

Page 20: ...es on left display Gives the beep intermittent and blue LED blinking when approach on settings torque When press key or Auto reset It makes judgment in the range or not after measurement then outputs...

Page 21: ...torque and timestamp If there is wireless LAN connection on the tool it outputs them NOTE The time of timestamp is at the key pressed If there is Auto memory reset setting the data are stored output...

Page 22: ...d the counter backward Press and hold it to fast forward Example Refer the data on counter 200 and timestamp Note When press key while display timestamp the counter moves and shows counter data immedi...

Page 23: ...ress to the next Example 2 To process data 101 to 200 Set counter to 200 and press key Set STT number to 101 and press to the next Set the number on right display to the lower end that you need using...

Page 24: ...ta 001 to 200 Set counter to 200 and press key Confirm STT shows 1 and press to the next Example 2 To process data 101 to 200 Set counter to 200 and press key Set STT number to 101 and press to the ne...

Page 25: ...200 and press key Set STT number to 101 and press to the next Example 3 To delete all data Set counter to 999 and press key Confirm STT shows 1 and press to the next Set the number on right display t...

Page 26: ...rd IEEE 802 11a b g n Frequency 11b g n 2 4 5GHz 11b g 2 4GHz 11n a 5GHz Transmission Speed 11b Max 11 Mbps 11a g Max 54 Mbps 11n Max 72 2 Mbps Modulation Method 11b DSSS 11a g n OFDM Authentication M...

Page 27: ...11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 R E 0 1 0 1 0 0 0 n m 1 2 3 4 5 6 A 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 1 8 1 0 2 2 1 3 4 5 1 0 CR LF Header 3 digits counte...

Page 28: ...27 Received error or setting error 1 2 3 4 5 6 7 8 9 10 R E 0 0 3 O K CR LF 1 2 3 4 5 6 7 8 9 10 11 12 13 R E 0 0 4 E R R O R CR LF...

Page 29: ...command to CEM3 G WF Display shows and can t measure the torque Send command AT047 0CRLF to enable the tool Upper and lower limite setting Response External device CEM3 WF R E 0 0 3 O K CR LF A T 0 3...

Page 30: ...0 Maximum capacity Has to be less than higher limit torque Trigger torque Trg 0 0 5 100 of capacity Tightening direction tUrn CW CW CCW BOTH Auto reset timer Ar 0 0 0 0 0 1 5 0 NG data processing ng N...

Page 31: ...ion mode Press to save setting and go to next Press to skip setting and go to next Press to return to Measurement mode Select the display mode using MEMCNT Memory counter display mode TORQUE High Low...

Page 32: ...surement mode Set the number using Move the digit using Press to save setting and go to next Press to skip setting and go to next Press to return to Measurement mode Select the tightening direction CW...

Page 33: ...o clear data NGAUTO Auto output Auto reset feature is applied even if though the judgment result is NG ix Buzzer setting x Auto power off setting Select buzzer turns ON or OFF using Press to save sett...

Page 34: ...g will be skipped when select WLAN or WLANDR xii Baud rate setting xiii Communication format setting Select the baud rate from 2400 4800 9600 or 19200 bps using Press to save setting and go to next Pr...

Page 35: ...Switch between date yy mm dd display or clock hh mm ss display using Press to get into Time date settings Press or to return to Measurement mode Set the hours using Press to save setting and go to ne...

Page 36: ...Press to skip setting and go to next Press to return to Measurement mode Set the month using Press to save setting and go to next Press to skip setting and go to next Press to return to Measurement m...

Page 37: ...EM3 WF Setting Software installation procedure i Download CEM3 WF Settings Software and USB driver from Tohnichi Mfg website https en global tohnichi com ii Install USB driver Please refer the install...

Page 38: ...37 v Click Next to proceed vi Click Install to proceed with the software installation...

Page 39: ...click Finish viii After installation the shortcut of CEM3WFSTS setting software will be created on the start menu desktop screen Trademarks Microsoft Windows and Windows Vista are registered trademark...

Page 40: ...seconds to get into Measurement mode setting Make sure display shows either MODE M or MODE T iii Connect the CEM3 G WF torque wrench and PC using USB cable iv Start CEM3WFSTS setting software v Click...

Page 41: ...rench 2 SubNet Mask Enter SubNet Mask for CEM3 G WF wrench 3 Default Gateway Enter Default Gateway for CEM3 G WF wrench 4 Communication Mode Select communication frequency Access Point Settings 1 SSID...

Page 42: ...connection 12 4 1 Battery setting for laptop or tablet PC There is concern to the wireless LAN connection due to battery setting if use laptop or tablet PC with default settings Please follow the ste...

Page 43: ...42 iii Click Change advanced power settings iv Pulldown Wireless Adapter Settings Power Saving Mode then select Maximum Performance for On battery Click OK to save the setting...

Page 44: ...r will be turned off to save battery and turn off Wireless LAN power LED Press to turn off tool power then press it again to turn on tool power and wireless LAN power iii When success the connection w...

Page 45: ...it again to turn on tool power and wireless LAN power iii Search on the wireless network on tablet PC then connect with the SSID of CEM3 WF_ Serial number Once success connection blue STATUS LED turn...

Page 46: ...ake sure to charge it before use How to install the battery i Turn the cap clockwise to remove it ii Set the battery in line with the hole as shown below and slide it in iii Connect the connector iv P...

Page 47: ...n the charger turns on Excessive charging may shorten the battery life iii The product can t operate when it is connected to the charger iv If green light on the charger turns on and the red light sta...

Page 48: ...428 3 549 5 N m kgf cm lbf in 2 400 2000 0 5 73 360 lbf ft Weight Effective Length Overall Length Grip Length Grip Width Height kg CEM10N3X8D G WF 208 212 63 5 35 6 47 0 54 QH8D SH RH QH HH 8D CEM20N...

Page 49: ...No reproduction or republication without written permission TOHNICHI Mfg CO LTD All Rights Reserved Torque accuracy 1 Display 7 segments LED 4 digits 14 segments LCD 6 digits 7 segments LCD 4digits OK...