19
[When judgment is NG]
The tool gives the solid red LED. Press
key to store and output data, press
key
to clear the measured data.
If there is "NGAUTO" output setting the data will be output automatically even if get
judgment result is NG. If there is wireless LAN connection on the tool, it outputs data.
vii.
Peak torque on the display will be reset and goes to next counter
NOTE: if there is a measured data on the counter number display shows it
8.2. High/ Low limit values display mode with judgment
Shows High/ Low limit values on left display. Gives the beep intermittent and blue LED
blinking when approach on settings torque. When press
key or Auto reset It makes
judgment in the range or not after measurement, then outputs data to the server
i.
Set measurement mode to “MODE-T”
ii.
Set display mode to “TORQUE” and High/ Low limit values
NOTE: if you set High/ Low limits to "0" tool does not judge.
On this instruction manual, set to 45 Nm for High limit, to 30 Nm for low limit for example.
iii.
Make sure the LCD left side display shows High/ Low limit values then measure
NOTE: Display can captures from about 7.5% of torque capability
iv.
The tool gives the beep intermittent and blue LED blinking when the torque value reaches
about 80% of low limit torque.