3.9.3 Serial Command
i)
Enable/Disable Auto-detection mode
Enable
:
SYNCMODE=3
Disable : SYNCMODE=0 or 1 or 2
ii) Timeout:
Label
disappear
(LFMOVELIM)
After detecting an object, the unit starts waiting for the object go out form the field of
view.
The limit time for the waiting can be configured. If the limit time is short, please remove
the object immediately. If large objects are supposed to be in the FOV, please set the
time
long.
iii) Timeout:
Decoding
(LFDECLIM)
The unit gives up decoding after trying to decode within specified time. The limit time
can
be configured. For barcodes which have large amount of data or difficulty to read, please
set the limit long.
iv)
Aimer setting during Auto-detection mode
(LFPOINTER)
Set the behavior of aimer while the unit is in Auto-detection mode and waiting an object
coming into the FOV.
v) Sensitivity
against
brightness
(VSENS)
Configure the sensitivity against brightness. If the unit tends to miss the object coming
in,
please set sensitivity higher.