Toastie Woodburners ELDUR Installation And Operating Instructions Manual Download Page 7

 Ref: 14/ST/BF/1 

These stoves have been designed to burn clean and efficiently only when operated correctly following 
the manufacturer’s guidance given in this manual.  

WARNING 

These  appliances  will  be 

HOT

  when  in  operation  and  due  care  should  be  taken  when 

operating the controls. 

Air Controls 

It is essential for the stove to have an adequate air supply for combustion and ventilation. 
The primary and secondary air inlets must be kept clear from obstruction. 

Primary Air 

Primary air is controlled via the two rotary air controls on the bottom of the door. 
This provides a conventional air draught to the bed of the fire. The primary air intakes can be adjusted 
to give the best possible results when burning different fuels. 

Secondary Air 

The  cast  iron  stove  is  fitted  with  an  “air  wash”  system.  This  secondary  air  supply  to  the  stove  is 
controlled through a slider assembly located at the top of the stove. 

 Note: The secondary air control is open when pushed to the right. 

Closed

 

 

Open

 

Multi-fuel Grate  

There are two types of multi-fuel grates for these stoves, Rotary style and grid style. For the rotary style 
grate, you can operate it by dragging the stainless steel rod forward and backward. For grid style grate, 
a  special  hook  is  supplied  to  de-ash.  It  is  important  to  de-ash  regularly,  to  ensure  that  the  primary 
airflow  is  not  impeded,  as  a  build-up  of  ash  can  damage  the  cast  iron  bed. 

Ashpan 

It is essential that  you empty the ashpan regularly. Use the supplied tool  to lift the ashpan out of  the 
stove. 

IMPORTANT

 - It is very important to empty the ashpan regularly. If the ash is allowed to build up on 

the underside of the grate then burnout or distortion of the grate may be caused 

On Solid Mineral Fuels 

Summary of Contents for ELDUR

Page 1: ...tructions IMPORTANT Installation MUST ONLY be carried out by a Gas Safe registered engineer installer Please read this user s Installation and Operating Instructions fully before installation and oper...

Page 2: ...OFNI 5KW ELDUR 6KW List of Components Description of Parts Stove parts Accessories 1 Ashpan 1 11 Glove 1 2 Coal Guard 1 12 Brush 1 3 Ashpan tool 1 4 Legs 4 5 Leg Height Screws 4 6 Leg Washers 4 7 Baff...

Page 3: ...ARE REQUIRED TO MOVE THE CRATE AND STOVE 1 Remove the outer packaging A Carefully remove the packing straps and lift off the upper crate B Remove the plastic bag and take down the stove from the bott...

Page 4: ...ve the fitted Flue Cover and refit on the rear opening 4 To fit the Baffle Insert the baffle upside down as shown ensuring you are holding the shorter of the two sides Turn the baffle as you fit it so...

Page 5: ...For each kW above 5kW 550 mm2 of fixed ventilation is required i e a stove rated at 8kW would require 3 x 550 mm2 1650 mm2 of fixed ventilation If more than one appliance is installed in the same roo...

Page 6: ...and top and at least 50mm at the back of the stove to obtain maximum heat output and for access to the rear of the stove All non combustible walls closer than 400mm to the stove should be at least 75...

Page 7: ...stove is fitted with an air wash system This secondary air supply to the stove is controlled through a slider assembly located at the top of the stove Note The secondary air control is open when push...

Page 8: ...ble it to dry out Burning wet or unseasoned wood will create tar deposits in the stove and chimney and will not produce a satisfactory heat output Lighting the Stove It is recommended to get the best...

Page 9: ...ch for signs of overfiring if any part of the stove starts to glow red the fire is in an overfire situation and the controls should be adjusted to immediately prevent the overfiring WARNING FUME EMISS...

Page 10: ...fibreglass rope is used on the stoves Inspect the rope around the door and glass If rope is becoming detached use a proprietary rope glue to reattach it Ensure you replace the rope in the case of it...

Page 11: ...draught stabilizer Consult a qualified installer Poor quality wood Do not continuously burn small wood Sticks bundles carpentry off cuts plywood pallets etc Smokes when lighting up Flue duct is cold B...

Reviews: