background image

OPERATION

Set the program switch to PROGRAM

OPERATION

PROGRAM

The channel indicators (A, B, C and D) and pause mode

indicator flash.

Press the PAUSE key.

PAUSE

Its indicator comes on, while the date indicators from
Monday to Sunday flash.

Press the STORE key.

STORE

The word "PASS" appears in the clock display, indicating that the
three days have been registered for pause.

(The contents of the program are not registered unless the STORE key is pressed.)

When the current day is set after the pause registration,  perform the new pause registration.

Set the program switch to OPERATION after finishing programing.

USING  FRONT-MOUNTED  AUTO/OFF

This switch  is used to stop actions of an output relay regardless of the timer program. When the switch is set to

AUTO, the relay functions as  programed. Setting the switch to OFF does not activate the relay. The switchover

is possible per channel.

Designate a day(s) of the week.

MON

TUE
WED

Press the day settings of Monday, Tuesday and Wednesday,

and each corresponding day indicator comes on.
When the  wrong day setting has been pressed, press that setting
again. The date indicator goes out.

13

All manuals and user guides at all-guides.com

Summary of Contents for TT-104B

Page 1: ...and precisely through individual key operation and display Setting the pause mode allows no program output to be delivered Output is a no voltage make contact that connects for five seconds at the pr...

Page 2: ...Program check correction and cancellation 5 Entire program cancellation 6 Program operation 7 Pause mode 8 Using front mounted AUTO OFF switch 9 Using manual switch 10 Using rear mounted channel assig...

Page 3: ...ys Use this keys to set a clock for the current hour To do this press this setting with the ADJUST key pressed continuously This setting is also used to set the time of the timer program Each time the...

Page 4: ...upplied with unit Write the names of programs of or equipment connected to each output channel in the label STORE key Press this key to store the day of the week or hours set under the day time or pau...

Page 5: ...ayer or spot announcing machine etc MEMORY BACK UP switch Be sure to set this switch to ON after installation This switch protects clock and stored programs for approximately 100 hours during power ou...

Page 6: ...is not in a range from zero hour 00 00 to 23 hundred 59 hours 23 59 both the date indicator and clock display flash and at the same time a warning tone beeps In such a case correct the hour 5 Press th...

Page 7: ...quipment connected and assign the output channel to each equipment If the same equipment are used but their programs are not the same assign different output channels Example If it is so programed as...

Page 8: ...omes on Press the THU setting Its indicator comes on Press the FRI setting Its indicator comes on MON TUE WED THU FRI When the wrong day setting has been pressed press the same setting again and the c...

Page 9: ...the STORE key to register the unreal hour other than one from 00 00 to 23 59 causes characters Err to appear in the clock display and the attempt of its registration is refused Correct the hour and re...

Page 10: ...p 10 to cancel the day of the week Press the TIME mode key The time mode indicator comes on and at the same time a dotted line flashes in the clock display Check the hour Each time the CHECK key is pr...

Page 11: ...ay Press the CANCEL key for cancelling the indicated hour and then set the new hour using the clock settings Register the new hour with the STORE key Be sure to cancel the previous hour when correctin...

Page 12: ...The PAUSE key is used to temporarily make the timer not to function on particular days This is possible for up to the 7th day from the day of registration No output is delivered from the timer on a da...

Page 13: ...pause registration perform the new pause registration Set the program switch to OPERATION after finishing programing USING FRONT MOUNTED AUTO OFF This switch is used to stop actions of an output rela...

Page 14: ...h channel as follows A 8 30 9 30 10 30 B 9 00 10 00 11 00 C 12 00 If all the switches are set to OFF A channel Output is delivered at 8 30 9 30 and 10 30 B channel Output is delivered at 9 00 10 00 an...

Page 15: ...amination day program 1 register the ordinary school hour program into the A channel Register Monday through Friday 2 register the Saturday program into the B channel Register Saturday 3 register the...

Page 16: ...utage However a clock works normally and stored programs are protected No relay output is produced After power restoration the timer works normally and indicates the current hour 2 A clock and stored...

Page 17: ...ours 30 steps per channel Day of the week hour minute output channel 4 channels A B C D No voltage dry make contact 5 seconds make output 24 V DC 0 5 A 5 seconds per month 25 C Day of the week hour mi...

Page 18: ...TOA Corporation Printed in Japan 133 05 276 50 All manuals and user guides at all guides com...