![Toa TS-910 s Operating Instructions Manual Download Page 15](http://html1.mh-extra.com/html/toa/ts-910-s/ts-910-s_operating-instructions-manual_1122444015.webp)
15
[Bottom]
[TS-911 setting switch label]
[TS-811 setting switch label]
RESET
OFF
OFF
PTT
100
10
1
ON
NOT USE
UNIT ID
ALT
VOTE
PRIORITY MODE
ON
ON
1
1
2
2
3
4
ON
PRIORITY
RESTORE
CHIME MUTE
RESET
OFF
PTT
100
10
1
ON
NOT USE
NOT USE
UNIT ID
ALT
PRIORITY
RESTORE
CHIME MUTE
PRIORITY MODE
ON
ON
1
1
2
2
3
4
Note
The figure below shows the setting switch labels for both models.
Remove the cover on the bottom side of the unit to expose its setting switches.
11
12
13
13
12
9
10
9
10
9. Priority operation setting switch
Following completion of a priority speech, this
switch is used to reset the operating status
of Conference units whose operations were
interrupted by the depression of a Priority Speech
key (7).
Set the switch to RESTORE in order to resume
the mode in operation prior to initiation of the
priority speech, and to RESET when resumption
is not desired.
Note
This switch is factory-preset to the RESET
position.
10. Priority chime mute switch
Disables the chime that sounds when the Priority
Speech key is pressed.
Set this switch to OFF when sound output is
desired, and to ON when no sound is desired.
Note
This switch is factory-preset to the OFF position.
11. Voting activation switch (TS-911 only)
Determines whether or not to start and terminate
voting from the Chairman unit.
Set the switch to ON to enable voting, or to OFF
to disable voting.
Note
This switch is factory-preset to the OFF position.
12. Priority speech key operation setting switch
Use to set the Priority speech key operation
mode.
PTT: Speech only possible while the Priority
speech key is being pressed.
ALT: Speech enabled when the Priority speech
key is pressed, and disabled when the key
is pressed again.
Note
The switch is factory-preset to PTT.
13. Unit address number setting switch
Set the unit address number (001 – 192), taking
care to ensure that the same number is not
duplicated in the system.
If the number [000] is assigned to a unit, the user
of that unit cannot speak. However, the unit can
be used for monitoring.
Set a numeral for the ones place and tens place.
Set this switch to OFF to set the hundreds place
to “0” and to ON to set it to “1.”
Note
This number is factory-preset to [000].