Toa SX-2000CI Operating Instructions Manual Download Page 5

5

[Rear]

DC 24V OUT

MAX. 0.1A

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

CONTROL

ON

OFF

CI/CO LINK

THROUGH

DATA

INPUT

10

11

12

14 15

16

13

10. Functional Earth Terminal [SIGNAL GND]

Hum noise may be generated when external
equipment is connected to the unit. Connecting
this terminal to the functional earth terminal of
the external equipment may reduce the hum
noise.

Note: 

This terminal is not for protective earth.

11. DC Power Input Terminal [DC POWER IN]

Connect an optional AD-011 or AD-031B DC
Power Supply Panel to this terminal.
Select the appropriate panel taking into
consideration the total current consumption of all
equipment to be connected to the power supply
unit. (See p. 10.)
When not using a redundant power system*,
connect the [+] terminal of input A to the [+]
terminal of input B, and the [–] terminal of input A
to the [–] terminal of input B. 
(See p. 11 and p. 13.)

* A method of connecting separate power

sources to each power input or connecting the
commercial power supply and backup power
supply separately to each power input to
prevent the system from going down when a
cable is broken or power fails.

12. 24 V DC Output Terminal [DC 24 V OUT]

This terminal supplies 24 V DC, max. 100 mA to
connected external equipment.

13. Control Input Terminals 

[CONTROL INPUT 1 – 32]

Photo coupler inputs. A current of approximately
2 mA flows when shorted, and the voltage
becomes approximately 24 V DC when opened.     
Activating the control input terminal causes the
control output terminal with the same channel
number (SX-2000CO) to close (provides make
contact).

14. CI/CO Link Through Switch [ON/OFF]

Normally, set this switch to the OFF position.

Note

This switch is set to "OFF" by default. 

15. CI/CO Link Through Terminal 

[CI/CO LINK THROUGH]

This terminal is not used.
Refer to the table below for the indicators'
functions and status.

16. CI/CO Link Data Terminal [CI/CO LINK DATA]

Connect this terminal to the CI/CO Link Terminal
of the SX-2000CO.
Refer to the table below for the indicators'
functions and status.

Functions

LED On or Flashing (green)

LED Off

LED On (orange)

1. CI/CO LINK status

Communication start

Communication stop

2. 

3. CI/CO LINK status

Communication start

Communication stop

4. CI/CO LINK connection 
    confirmation

Unconnected

Connected

CI/CO LINK

THROUGH

DATA

1

2

3

4

[Indicators' functions and status of the CI/CO Link Through/Data terminals]

Summary of Contents for SX-2000CI

Page 1: ...trol Output Unit Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment TABLE OF CONTENTS 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 16 POWER CPU OFF FAULT...

Page 2: ...wise may result in fire or electric shock SX 2000CI and SX 2000CO are designed exclusively to be mounted in an equipment rack Be sure to follow the instructions below when rack mounting the unit Failu...

Page 3: ...ts the contact data of multiple channels to be transmitted to the remote locations with simple wiring The front mounted indicators of each unit show the control input status or control output status T...

Page 4: ...ed This indicator is not used 4 FAULT Indicator FAULT Yellow Lights when communications with the connected SX 2000CO are interrupted 5 USB Port USB This port is not used 6 RUN Indicator RUN Green Norm...

Page 5: ...ystem from going down when a cable is broken or power fails 12 24 V DC Output Terminal DC 24 V OUT This terminal supplies 24 V DC max 100 mA to connected external equipment 13 Control Input Terminals...

Page 6: ...ights when the power is switched on 3 CPU OFF Indicator CPU OFF Red This indicator is not used 4 FAULT Indicator FAULT Yellow Lights when communications with the connected SX 2000CI are interrupted 5...

Page 7: ...connecting the commercial power supply and backup power supply separately to each power input to prevent the system from going down when a cable is broken or power fails 12 Control Output Terminals C...

Page 8: ...ews Ensure that the wire does not break free when pulled If the wire does pull free repeat the connection procedure from the start Step 2 Insert the wired terminal plug into the corresponding terminal...

Page 9: ...2000CO separately See p 11 and 15 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 16 POWER CPU OFF FAULT CONTROL INPUT UNIT SX 2000CI 17 25 18 26 19 27 20 28 21 29 22 30 23 31 24 32 CONTROL INPUT 1 9 2 10 3 11 4...

Page 10: ...is still supplied from the other unit preventing the system from going down DC 24V OUT MAX 0 1A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 CONTROL ON OFF CI...

Page 11: ...supply panels to the SX 2000CI only Connect the DC power input terminals of the SX 2000CI to those of the SX 2000CO and the CI CO link data terminals of the SX 2000CI to those of the SX 2000CO via th...

Page 12: ...lled on a desk or to a wall STP Category 5 straight cable with RJ45 connectors STP Category 5 straight cable with RJ45 connectors Unit mm AD 011 DC power supply panel AWG14 18 AWG14 18 AWG14 18 AWG14...

Page 13: ...n the power is supplied from the SX 2000CI side refer to the table on p 11 Connections It is recommended to use an optional RM 200RJ Terminal Unit that serves wiring conversion between the CPEV cable...

Page 14: ...rent 2 mA 16P removable terminal plug supplied with the SX 2000CI Cable AWG22 28 twisted pair cable Control input terminals OUTPUT CHANNEL 24 V DC 0 5 A 4 5 Control Output Connections SX 2000CO Only T...

Page 15: ...ta terminal Factory preset OFF CI CO link through switch OFF Factory preset OFF ON OFF CI CO LINK THROUGH DATA CI CO LINK THROUGH DATA ON OFF The SX 2000CI and SX 2000CO can be connected using the shi...

Page 16: ...G ON SETTING ON Step 3 Set the link through switch on the SX 2000CI CO s rear panel to the OFF position Note The CI CO link through switch is set to OFF by default SX 2000CI rear DC 24V OUT MAX 0 1A 1...

Page 17: ...erminal number of the control input the higher the priority level For example closing the control input 1 while the control input 2 is closed causes the control output 2 to open Opening the control in...

Page 18: ...100 ms Control input 1 Closed Closed Open Control input 2 Control output 1 Closed Closed Closed Open Open Control output 2 5 2 4 First in first out DIP switch 3 ON DIP switch 4 ON The first control in...

Page 19: ...power supply to each unit 1 pair for data line When connecting the power supply only to the SX 2000CI 1 pair data line and 2 pair power line for a redundant power supply system or 1 pair data line and...

Page 20: ...1 pair data line and 1 pair power line for a non redundant power supply system Branch cable STP Category 5 straight cable Maximum Cable Distance 800 m Maximum Delay Time 300 ms Operating Temperature...

Reviews: