When Installing the Unit

• Do not expose the unit to rain or an environment

where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock. 

• Use the unit only with the voltage specified on the

unit. Using a voltage higher than that which is
specified may result in fire or electric shock.

• Since the unit is designed for in-door use, do not

install it outdoors. If installed outdoors, the aging of
parts causes the unit to fall off, resulting in personal
injury. Also, when it gets wet with rain, there is a
danger of electric shock. 

When the Unit is in Use 

• Should the following irregularity be found during

use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest TOA dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock. 

· If you detect smoke or a strange smell coming

from the unit.

· If water or any metallic object gets into the unit 
· If the unit falls, or the unit case breaks 
· If it is malfunctioning (no tone sounds.)

• To prevent a fire or electric shock, never open nor

remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
qualified service personnel.

• Do not place cups, bowls, or other containers of

liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock. 

When Installing the Unit

• Avoid installing the unit in humid or dusty locations,

in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock. 

• SX-2000CI and SX-2000CO are designed

exclusively to be mounted in an equipment rack. 
Be sure to follow the instructions below when rack-
mounting the unit. Failure to do so may cause a fire
or personal injury.

· Install the equipment rack on a stable, hard floor.

Fix it with anchor bolts or take other arrangements
to prevent it from falling down.

· When connecting the power cord of the DC

power supply panel for the SX-2000CI/CO to an
AC outlet, ensure that the total load current never
exceeds the AC outlet’s allowable current
capacity.

· The supplied rack-mounting screws can be used

for the TOA equipment rack only. Do not use
them for other racks.

When the Unit is in Use 

• Use the specified DC power supply unit AD-011 or

AD-031B for the unit. Note that the use of other DC
power supply unit may cause a fire.

1. SAFETY PRECAUTIONS

• Before installation or use, be sure to carefully read all the instructions in this section for correct and safe

operation.

• Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or

cautions regarding safety.

• After reading, keep this manual handy for future reference.

Safety Symbol and Message Conventions 

Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards. 

WARNING

Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.

WARNING

CAUTION

CAUTION

Summary of Contents for SX-2000CI

Page 1: ...trol Output Unit Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment TABLE OF CONTENTS 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 16 POWER CPU OFF FAULT...

Page 2: ...wise may result in fire or electric shock SX 2000CI and SX 2000CO are designed exclusively to be mounted in an equipment rack Be sure to follow the instructions below when rack mounting the unit Failu...

Page 3: ...ts the contact data of multiple channels to be transmitted to the remote locations with simple wiring The front mounted indicators of each unit show the control input status or control output status T...

Page 4: ...ed This indicator is not used 4 FAULT Indicator FAULT Yellow Lights when communications with the connected SX 2000CO are interrupted 5 USB Port USB This port is not used 6 RUN Indicator RUN Green Norm...

Page 5: ...ystem from going down when a cable is broken or power fails 12 24 V DC Output Terminal DC 24 V OUT This terminal supplies 24 V DC max 100 mA to connected external equipment 13 Control Input Terminals...

Page 6: ...ights when the power is switched on 3 CPU OFF Indicator CPU OFF Red This indicator is not used 4 FAULT Indicator FAULT Yellow Lights when communications with the connected SX 2000CI are interrupted 5...

Page 7: ...connecting the commercial power supply and backup power supply separately to each power input to prevent the system from going down when a cable is broken or power fails 12 Control Output Terminals C...

Page 8: ...ews Ensure that the wire does not break free when pulled If the wire does pull free repeat the connection procedure from the start Step 2 Insert the wired terminal plug into the corresponding terminal...

Page 9: ...2000CO separately See p 11 and 15 1 9 2 10 3 11 4 12 5 13 6 14 7 15 8 16 POWER CPU OFF FAULT CONTROL INPUT UNIT SX 2000CI 17 25 18 26 19 27 20 28 21 29 22 30 23 31 24 32 CONTROL INPUT 1 9 2 10 3 11 4...

Page 10: ...is still supplied from the other unit preventing the system from going down DC 24V OUT MAX 0 1A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 CONTROL ON OFF CI...

Page 11: ...supply panels to the SX 2000CI only Connect the DC power input terminals of the SX 2000CI to those of the SX 2000CO and the CI CO link data terminals of the SX 2000CI to those of the SX 2000CO via th...

Page 12: ...lled on a desk or to a wall STP Category 5 straight cable with RJ45 connectors STP Category 5 straight cable with RJ45 connectors Unit mm AD 011 DC power supply panel AWG14 18 AWG14 18 AWG14 18 AWG14...

Page 13: ...n the power is supplied from the SX 2000CI side refer to the table on p 11 Connections It is recommended to use an optional RM 200RJ Terminal Unit that serves wiring conversion between the CPEV cable...

Page 14: ...rent 2 mA 16P removable terminal plug supplied with the SX 2000CI Cable AWG22 28 twisted pair cable Control input terminals OUTPUT CHANNEL 24 V DC 0 5 A 4 5 Control Output Connections SX 2000CO Only T...

Page 15: ...ta terminal Factory preset OFF CI CO link through switch OFF Factory preset OFF ON OFF CI CO LINK THROUGH DATA CI CO LINK THROUGH DATA ON OFF The SX 2000CI and SX 2000CO can be connected using the shi...

Page 16: ...G ON SETTING ON Step 3 Set the link through switch on the SX 2000CI CO s rear panel to the OFF position Note The CI CO link through switch is set to OFF by default SX 2000CI rear DC 24V OUT MAX 0 1A 1...

Page 17: ...erminal number of the control input the higher the priority level For example closing the control input 1 while the control input 2 is closed causes the control output 2 to open Opening the control in...

Page 18: ...100 ms Control input 1 Closed Closed Open Control input 2 Control output 1 Closed Closed Closed Open Open Control output 2 5 2 4 First in first out DIP switch 3 ON DIP switch 4 ON The first control in...

Page 19: ...power supply to each unit 1 pair for data line When connecting the power supply only to the SX 2000CI 1 pair data line and 2 pair power line for a redundant power supply system or 1 pair data line and...

Page 20: ...1 pair data line and 1 pair power line for a non redundant power supply system Branch cable STP Category 5 straight cable Maximum Cable Distance 800 m Maximum Delay Time 300 ms Operating Temperature...

Reviews: