10
Update completion
Click the "Exit" button to close the screen.
Notes
• Error message such as "No response" may be displayed on the "Now updating the firmware"
screen. In this case, unplug the USB cable and reset the AI and AO. Wait for approximately one
minute, then retry from
Step 3-2
.
• Never unplug the USB cable or exit the file in operation till the "Complete" screen appears.
• If the "Abort" button is clicked during flash memory write, the writing is aborted.
Step 3-5.
Unplug the USB cable from the AI or AO.
Step 3-6.
(Only when updating the AI or AO with Ver. 2.00 or later installed)
Set the DIP switch 7 back to the OFF position.
Step 3-7.
Reset the AI or AO.
Press the reset key inside the protective cover to reset the device.
When all devices within the system are connected via Analog link, pressing the Reset key on the
SM resets all AI and AO units at once.
Check to see that updated version number is displayed in the fluorescent display on the front
panel.
Step 3-8.
Replace the protective cover.