Do not block cover ventilation holes.
The amplifier should not be placed in areas;
1. with poor ventilation
2. exposed to direct sunlight.
3. with high ambient temperature or adjacent to heat-generating
equipment.
4. with high humidity or dusty levels.
5. susceptible to vibration.
To mount the amplifier in a standard 19-inch equipment rack, use
the MB-931A Rack-mounting Bracket accessory.
Remove 4 screws securing case.
When all connections are completed, turn power switch on. Then,
the meter is illuminated. Approx. 5 seconds after switching power
on, the amplifier comes into operation.
ADJUSTMENT OF VOLUME CONTROL
Adjust the input volume control to obtain appropriate output level.
In normal use of BGM playing or announcement, the deflection of
the meter is recommended to be within the range as indicated in the
drawing. Tone quality will be considerably deteriorated if the
pointer indicates around 0 VU.
Fix the MB-931A with attached 4 screws.
MB-931A The
length
of
the
screws should not
(Silver) exceed
12mm
(1/2
inches).
(OPTION)
Perforated Panel
PF-911 (OPTION)
(Silver)
If two or more amplifiers are mounted in
an equipment rack, space should be pro-
vided between the units for ventilation.
The PF-911 Perforated Panel is recom-
mended for this purpose.
In normal use of BGM
playing or announcement.
The pointer of meter indicates 0 VU if continuous signals like sine
waves are applied to the input of the amplifier.
Continuous signals
When the power amplifier is used in combination with a mixer pre-
amplifier, adjust the total gain at the mixer preamplifier with the
gain setting of the power amplifier at maximum.
•
Unpacking
Upon receipt of the amplifier shipment, please inspect for any
damage incurred in transit. If damage is found, please notify your
local TOA representative and the transportation company
immediately.
State date, nature of damage, whether any damage was noticed on
the shipping container, prior to unpacking. Please give waybill
number of shipping order.
• Failure
Should amplifier fail, contact your nearest TOA authorized con-
tractor or service center.
Installation
Rack Mounting
Operation
Servicing