[Notification for North America]

FCC REQUIREMENTS

General Requirements For All Equipment:

 1.    This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On 

the top cover of this equipment is a label that contains, among other information, a product identifier in the 

format US: AAAEQ##TXXXX.

   If requested, this number must be provided to the telephone company.

 2.  USOC Jack RJ11C or RJ11W.

 3.    A plug and jack used to connect this equipment to the premises wiring and telephone network must comply 

with the applicable FCC Part 68 rules and requirements adopted by the ACTA.

   A compliant telephone cord and modular plug is provided with this product.

   It is designed to be connected to a compatible modular jack that is also compliant.

   See installation instructions for details.

 4.    The REN is used to determine the number of devices that may be connected to a telephone line. Excessive 

RENs on a telephone line may result in the devices not ringing in response to an incoming call.

   In most but not all areas, the sum of RENs should not exceed five (5.0).

     To be certain of the number of devices that may be connected to a line, as determined by the total RENs, 

contact the local telephone company.

     For products approved after July 23, 2001, the REN for this product is part of the product identifier that has 

the format US: AAAEQ##TXXXX.

   The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3).

   For earlier products, the REN is separately shown on the label.

 5.    If this equipment [N8KCOCU] causes harm to the telephone network, the telephone company will notify you 

in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, 

the telephone company will notify the customer as soon as possible. Also, you will be advised of your right 

to file a complaint with the FCC if you believe it is necessary.

 6.    The telephone company may make changes in its facilities, equipment, operations or procedures that could 

affect the operation of the equipment.

     If this happens the telephone company will provide advance notice in order for you to make necessary 

modifications to maintain uninterrupted service.

 7.    I f trouble is experienced with this equipment [N8KCOCU], for repair or warranty information, please contact 

TOA Electronics, Inc.,1350 Bayshore Highway, Suite 270 Burlingame, California 94010, phone (650) 452-

1200.

     If the trouble is causing harm to the telephone network, the telephone company may request you remove 

the equipment from the network until the problem is resolved.

 8.    If there is a section in the general customer instructions that provides detailed information on repairs, a 

reference to that section is acceptable.

     If  this  equipment  is  of  a  type  that  is  not  intended  to  be  repaired,  state  that  fact  in  place  of  any  repair 

instructions.

 9.  Connection to party line service is subject to state tariffs.

     Contact  the  state  public  utility  commission,  public  service  commission  or  corporation  commission  for 

information.

 10.   If your home has specially wired alarm equipment connected to the telephone line, ensure the installation 

of this [N8KCOCU] does not disable your alarm equipment.

     If  you  have  questions  about  what  will  disable  alarm  equipment,  consult  your  telephone  company  or  a 

qualified installer.

 11. Customer Information 4 July 2003

   This equipment is hearing aid compatible.

Summary of Contents for N-8000CO

Page 1: ...free use of your equipment 1 SAFETY PRECAUTIONS 2 2 GENERAL DESCRIPTION 6 3 FEATURES 7 4 NOMENCLATURE AND FUNCTIONS 7 Front 7 Rear 7 5 INSTALLATION 8 5 1 Equipment Rack Mounting 8 5 2 Desk Top Instal...

Page 2: ...mpt to operate the unit in this condition as this may cause fire or electric shock If you detect smoke or a strange smell coming from the unit If water or any metallic object gets into the unit If the...

Page 3: ...et contacter le repr sentant TOA le plus proche Ne pas essayer pas d utiliser l appareil dans ces conditions sous peine de provoquer un incendie ou une lectrocution D tection de fum e ou d une odeur...

Page 4: ...e company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible A...

Page 5: ...analog content and billing protection affidavit be provided the telephone company Customer instructions must contain information on the preparation and submission of the affidavit Systems The consume...

Page 6: ...thority or electrician as appropriate To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord Notification for Europe NOTICE The interconnected telecommunication terminal e...

Page 7: ...inlet Connect the supplied power cord Note If there is a danger of lightning strikes insert an appropriate surge arrester into the power line 10 Subscriber Line Connection Terminal C O LINE Connect t...

Page 8: ...power strips A Temp rature ambiante lev e si l appareil est install dans un b ti ferm ou en m me temps que d autres appareils la temp rature l int rieur risque de devenir sup rieure la temp rature am...

Page 9: ...delle en fibre pour M5 2 Vis de montage en b ti 5 x 12 2 Vis de m canique 3 x 12 2 Coupleur 2 Patte de montage 2 Vis taraud 3 x 14 2 Use the optional MB 15B J hardware set when mounting 2 units Utilis...

Page 10: ...ssory Machine screw M3 x 8 accessory Vis de m canique M3 x 8 accessoire Pied en plastique accessoire When installing the N 8000CO on a desk secure the supplied plastic feet to the unit s bottom using...

Page 11: ...short as possible Remarque Protection contre les ruptures d alimentation prise d alimentation D verrouillez le collier cordon et glissez y le cordon d alimentation Le c ble entre la prise d alimentati...

Page 12: ...interface unit Note The Interface Unit s DC resistance is 352 maximum Depending on line resistance conditions the unit might not be usable 1 Select an appropriate UPS taking into consideration the to...

Page 13: ...8000CO 2 C O line connection Connect the C O line to the PSTN public switched telephone network using the supplied mini clamp connector Refer to p 14 Connector Connection To reduce the rick of fire us...

Page 14: ...ace Cover transparent side Cable Mini clamp connector accessory model 232D 02S1B DA5 manufactured by DDK Ltd Rear panel 6 2 Type of Cable The types of cables are to be determined according to the foll...

Page 15: ...g maintenance use 1 Mini clamp connector 2P 2 Plastic foot 4 Machine screw M3 x 8 4 Rack mounting bracket MB 15B BK for rack mounting one N 8000CO unit MB 15B J for rack mounting two N 8000CO units Wa...

Page 16: ...for Europe Manufacturer TOA Corporation 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Japan Authorized representative TOA Electronics Europe GmbH Suederstrasse 282 20537 Hamburg Germany URL https www...

Reviews: