Rear Panel
Speaker Jacks
(SPEAKERS)
The speaker outputs are stan-
dard 1/4" phone jacks wired in
parallel. Speaker cables (recom-
mend at least #18 gauge wire)
should be connected between
the MX-101 and the speaker
systems prior to applying pow-
er to the unit.
System Output Jack
(SYSTEM OUT)
The System Out jack is pro-
vided for connection to external
equalizers and / or power amps.
Nominal output level is +4dB
with an impedance of 600
ohms.
Caution
- The MX-101 should
never be operated into less than
a 4 ohms speaker load.
Foldback Output Jack
(FB OUT)
This jack is for connection to
external power amplifiers and /
or equalizers for the on-stage
monitoring system. Nominal
output level is +4dB with an
impedance of 600 ohm.
Caution:
To insure maximum cooling of
the MX-101, adequate clearance
should be maintained between
the rear panel and any other
surface ( 4 - 6 inches should do).
The vents on the bottom and
top of the MX-101 are also
provided for convection cool-
ing. These vents should be kept
clear and open. Failure to do so
may cause thermal shut-down
of the unit.
Power Switch
(POWER)
The power switch is a three-
position type with the middle
position being the "off" posi-
tion. The MX-101 should be
operated in the switch position
which produces the lowest
amount of system hum.
AC Power Cord
The power cord is the three-
wire type with proper ground-
ing facilities.
Earth Terminal (GND)
AC Fuse
Caution
- The ground pin
should not be removed under
any circumstances. If the MX-
101 must be used without prop-
er grounding facilities, a suit-
able grounding adapter should
be utilized.
Operation of the MX-101 with
proper grounding techniques
will result in less system noise
and greatly reduced shock
hazard.
Warning
To avoid possible equipment
damage and / or personnel in-
jury, the fuse should always be
replaced with same type and
rating. Using improper fuses
will also void the warranty. The
MX-101 should always be dis-
connected from AC outlet prior
to changing fuses. If fuses repe-
atedly fails, the unit should be
referred to qualified service per-
sonnel for repair.
Fault Protection Table
Fault
Excessive current due to
overloads.
Short circuits
(less than 0.4-ohm)
Temperature rise of heat
sink
(more than 105°C)
DC drift
Protection
Current limiter activates
at less than 2 ohm.
Current limiter activates
input signal is lowered,
unit shuts down.
Input signal is lowered.
Unit shuts down
Input signal is lowered.
Unit shuts down
Indication
Compressor
LED illuminates
Amp protection
LED illuminates.
Amp protection
LED illuminates.
Amp protection
LED illuminates.
Action
Remove excessive loads
Minimum speaker loads
4 ohm.
Check speaker
lines/systems for shorts.
Check for adequate
ventilation.
Refer to qualified service
personnel
Restoration
Automatic restoration
after normal loads are
obtained.
Turn off power switch.
Turn on into operational
loads.
Automatic restoration
after temperature
lowers (to 75° - 95° C)
Automatic restoration
after normal bias is
regained
— 4 —