When Installing the Unit

 

• To avoid damage to the unit and/or connected

equipment:
· Never connect the IR-820SP or IR-802T

connection terminal to a PC or LAN.

· Never short-circuit the terminal to ground.

• Be sure to follow the instructions below when

rack-mounting  the  unit.  Failure  to  do  so  may

cause a fire or personal injury.
· Install the equipment rack on a stable, hard

floor.  Fix  it  with  anchor  bolts  or  take  other

arrangements to prevent it from falling down.

· Rack-mounting screws are not supplied with

the  unit.  Prepare  them  that  are  appropriate

for the equipment rack.

Note: 

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  B  digital 

device,  pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable 

protection  against  harmful  interference  in  a  residential  installation.  This    equipment    generates, 

uses  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in  accordance  with 

the  instructions,  may  cause  harmful  interference  with  radio  communications.  However,  there  is 

no  guarantee  that  interference  will  not  occur  in  a  particular  installation.  If  this  equipment  does 

cause harmful interference to radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the interference by one or more of 

the following measures:

 

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and the receiver.

• Connect the equipment into an outlet on a circuit different from that to which the receiver is

connected.

• Consult the dealer or an experienced radio/television technician for help.

3. GENERAL DESCRIPTION

The  IR-801AF  US  DQ  is  an  Audio  interface  unit  designed  for  exclusive  use  with  TOA’s  Infrared 

wireless  microphone  system*  consisting  of  the  IR-310M  Infrared  Wireless  Microphone,  IR-802T 

Infrared Wireless Tuner, and IR-820SP Infrared Wireless Speaker. 

Via IR-801AF US DQ, two IR-820SP and two IR-802T are available to connect.  

Two infrared signals from each IR-820SP are mixed and distributed to each IR-802T. 

In  combine  mode,  two  audio  signals  from  each  IR-802T  are  mixed  and  distributed  to  each  IR-

820SP. And in separate mode, each audio signals from two IR-802T passes through into each IR-

820SP. 

The IR-801AF US DQ is equipped with a single channel wireless tuner having a fixed frequency. It 

makes a priority the IR-310M Y PQ and makes mute other infrared microphone when receiving a 

priority control signal transmitted through the priority switch operation of the IR-310M Y PQ.

 

* A PA system designed for use in the school classrooms.

FCC Compliance

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following 

two conditions:

 

(1) this device may not cause harmful interference, and

(2)  this device must accept any interference received, including interference that may cause

undesired operation.

Any modifications made to this device that are not approved by TOA Corporation may void

the authority granted the user by the FCC to operate this equipment.

CAUTION

 

Indicates a potentially hazardous situation 

which, if mishandled, could result in moderate or 

minor personal injury, and/or property damage.

 

Summary of Contents for IR-801AF

Page 1: ...ss microphone system is comprised of the following components IR 802T CU AQ IR 802T CU 1Q Infrared Wireless Tuner IR 820SP Y 4Q Infrared Wireless Speaker IR 310M Y PQ and IR 200M Y 4Q Infrared Wireles...

Page 2: ...ge class room 7 7 2 Four channels system for dual zone class rooms 7 7 3 Two channels system for large class room 8 8 CONNECTIONS 8 8 1 Connections for four channels system 8 8 2 Connections for two c...

Page 3: ...rsonnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatu...

Page 4: ...nto an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio television technician for help 3 GENERAL DESCRIPTION The IR 801AF US DQ is...

Page 5: ...he unit s power then wipe with a dry cloth If the unit is extremely dirty use a cloth moistened in a neutral detergent Do not use benzene thinner alcohol and chemically processed towels as they can di...

Page 6: ...ess Speaker using a Category 5 cable straight type 8 IR 802T CU 1Q connection terminal Connect this terminal to the IR 802T CU 1Q Infrared Wireless Tuner using a Category 5 cable straight type 9 DC in...

Page 7: ...red Wireless Speaker IR 820SP Y 4Q Infrared Wireless Speaker IR 802T CU AQ Infrared Wireless Tuner For class room 1 IR 802T CU 1Q Infrared Wireless Tuner For class room 2 IR 200M Y 4Q Infrared Wireles...

Page 8: ...IR 820SP Y 4Q Infrared Wireless Speaker IR 820SP Y 4Q Infrared Wireless Speaker Category 5 cable straight type Category 5 cable straight type IR 820SP Y 4Q IR 820SP Y 4Q IR 801AF US DQ IR 802T CU 1Q...

Page 9: ...onnected equipment Never connect the IR 820SP or IR 802T connection terminal to a PC or LAN Never short circuit the terminal to ground Category 5 cable straight type IR 820SP Y 4Q IR 820SP Y 4Q IR 801...

Page 10: ...in IR 801AF US DQ The channel B 1 and 2 as the student microphone are muted IR 802T CU AQ Infrared Wireless Tuner IR 802T CU 1Q Infrared Wireless Tuner IR 200M Y 4Q Infrared Wireless microphone Stude...

Page 11: ...frared Wireless microphone Student 2 channel 2 IR 310M Y PQ Infrared Wireless Microphone Teacher 1 channel A IR 200M Y 4Q Infrared Wireless Microphone Student 1 channel B IR 801AF US DQ Audio Interfac...

Page 12: ...Channel A 3 100 MHz Operating Temperature 10 to 50 C 14 to 122 F Operating Humidity 90 RH or less no condensation Finish Control section ABS resin Black Dimensions 210 w x 44 h x 181 d mm 8 27 x 1 73...

Reviews: