background image

Continuous: 60 W (8

) (IEC6026-5)

Program: 120 W (8

)

(Measured by installing the unit in the center of a ceiling or wall)

81 dB (1 W, 1 m) Installation in free sound field (Measured in anechoic chamber)

(Measured by installing the unit in the center of a ceiling or wall)

Low frequency : 16 cm (6.5”) cone-type
ø
Maximum ceiling thickness: 37 mm (1.5”)

ø 280 mm (11”) X Depth 198 mm (7.8”)
6.3 kg (including mounting accessories)

100 V line:
70 V line:
25 V line:
8

170

 (60 W), 330

 (30 W), 670

 (15 W), 3.3k

 (3 W)

83

 (60 W), 170

 (30 W), 330

 (15 W), 670

 (7.5 W), 3.3k

 (1.5 W)

83

 (7.5 W), 170

 (3.7 W), 330

 (1.9 W), 670

 (0.9 W), 3.3k

 (0.2 W)

Accessories

Optional Components

Be sure to read the instructions manual in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages 
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.

Safety symbols and messages described below are used in this manual to prevent bodily injury and property 
damage  which  could  result  from  mishandling.  Before  operating  your  product,  read  this  manual  first  and 
understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards.

Safety Symbol and Message Conventions

Indicates a potentially hazardous situation which, if mishandled, could 
result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could 
result in  moderate or minor personal injury, and/or property damage.

Leave the installations to your TOA dealer because 
the installation requires expert knowledge.Improper 
installation  may  cause  the  unit  to  fall,  resulting  in 
personal injury and/or property damage.

Install  the  unit  in  a  location  that  can  structurally 
support  the  weight  of  the  unit  and  its  mounting 
hardware.  Doing  otherwise  may  result  in  the  unit 
falling  down  and  causing  personal  injury  and/or 
property damage.

Do not use other methods than specified to mount 
the unit. Extreme force is applied to the unit and the 
unit  could  fall  off,  possibly  resulting  in 
injuries.

Attach the safety wire to the unit. If not attached, 
unit could fall off, resulting in personal injury.

Tighten  each  screw  securely.  Ensure  that  the  unit 
has  no  loose  joints  after  installation  to  prevent 
accidents that could result in personal injury.

Do not push speaker surface when installation unit 
to ceiling. Resulting in unit damage.

Use  the  specified  mounting  hardware  in 
combination. Doing otherwise may cause the unit or 
component to fall off, resulting in personal injury.

Should the following irregularity be found during use, 
immediately stop operating the unit and contact your 
nearest  TOA  dealer.  Further  attempt  to  use  under 
this condition may cause fire or electric shock.

If  you  detect    smoke  or  a  strange  smell  coming 
from the unit
If no tone sounds

Avoid installing the unit in humid or dusty locations, 
in locations exposed to the direct sunlight, near the 
heaters, or in loactions generating sooty smoke or 
steam  as  doing  otherwise  may  result  in  fire  or 
electrical shock.

Do  not  operate  the  unit  for  an  extended  period  of 
time with the sound distorting. This is an indication of 
a  malfunction,  which  in  turn  can  cause  heat  to 
generate and result in a fire.

Avoid  touching  the  unit’s  sharp  metal  edge  to 
prevent injury.

Summary of Contents for FB-2862C-AS

Page 1: ...ollow the instructions in this manual to ensure long trouble free use of your equipment URL http www toa com sg 133 01 00102 00 2 Traceability Information for Europe Manufacturer TOA Corporation 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Japan Authorized representative TOA Electronics Europe GmbH Suederstrasse 282 20537 Hamburg Germany ...

Page 2: ... TOA dealer because the installation requires expert knowledge Improper installation may cause the unit to fall resulting in personal injury and or property damage Install the unit in a location that can structurally support the weight of the unit and its mounting hardware Doing otherwise may result in the unit falling down and causing personal injury and or property damage Do not use other method...

Page 3: ...ive sounds Easy installations can be quickly and accurately mounted to ceiling and walls Rotating front grille can be installed quickly and conveniently Attractive exterior design specially created by an interior designer blends naturally with any architectural space enhancing the immediate area s sense of harmony Optional mounting hardware permits installation in weak ceiling panels Use of its su...

Page 4: ...d downward it likely has not yet been fully rotated back to the detachment position In such cases take care to rotate the grille fully counterclockwise in order to release the lock Tip 6 1 Detaching the Front Grille Rotate the 4 mounting tab axis screws counterclockwise The mounting tabs rise as they turn allowing the speaker to be removed When loosening the mounting tab axis screws support the sp...

Page 5: ...ry LOCK Use the supplied ceiling reinforcement ring Direct mounting to a ceiling panel Use the supplied ceiling reinforcement ring in conjunction with the optional HY TB1 Tile Bar Bridge Mounting to a ceiling frame Use the supplied ceiling reinforcement ring in conjunction with the optional HY AH1 Anchor Hanging Bracket Mounting to an anchor bolt Ceiling panel ø250 5 mm 9 8 0 2 Tip The following m...

Page 6: ...hor Hanging Bracket Note Refer to the instruction manual included with the HY AH1 for the correct mounting procedure Anchor bolt HY AH1 optional Ceiling panel Ceiling reinforcement ring accessory To attach tie one end of the supplied safety wire around the speker s safety wire hook and tie its snap ring around a secure C channel bar or anchor bolt in the ceiling Safety wire hook Safety wire access...

Reviews: