< PROGRAMMING  DATA  TABLE  1 >

Function Table for the System

Function

Group

S

Function

Numbering schedules
of tie-line  system

Selection of
Calling Tone

Selection  of  Paging

Pre-announcement

Tone

Time-out of

conversation

Time-out of

Paging call

Function

code

40

41

42

45

46

Registered

data

A

B

C

00

00

00

——

Note of  Registration

Select the  head  number  of  stations

in each exchange from  among the

followings:

100, 200, 300, 400, 500, 600, 700,

800 or 900

0: Without Calling Tone

1: Single tone (0.2 sec.)

2: Calling tone (0.3 sec.)

0:  Without  Paging

Pre-announcement Tone

1 :  Paging Pre-announcement

Tone (1 sec.)

2:  Paging  Pre-announcement

Tone (2 sec.)

00: Without Time-out function

01  ~ 99:  Length  limited  (min.)

00: Without Time-out function

01  ~99:  Length limited  (min.)

Initial programming

A/B/C=
200/470/740

or

A/B/C=

100/400/700

1:

Calling Tone

(0.3 sec.)

2:

Paging

Pre-announcement

Tone (2 sec.)

00:

Without Time-out

00:

Without Time-out

— 42 —

All manuals and user guides at all-guides.com

Summary of Contents for EXES 6000 CP-63

Page 1: ...or Tie line System EXES 6000 CP 63 For INTERCOM SYSTEM TOA EXES 6OOO INTERCOM SYSTEM CP 63 INSTALLATION HAND BOOK TOAELECTRICCO LTD KOBE JAPAN 133 21 081 1 All manuals and user guides at all guides co...

Page 2: ...oup Blocking 3 Allowing Group Access to Paging FUNCTION CODE 50 51 52 53 54 56 57 58 59 60 61 62 70 71 72 81 82 21 22 23 24 25 27 28 29 30 31 32 33 34 35 36 37 38 Function Group E 7 18 Programmable St...

Page 3: ...that careful study of the necessary parts of this booklet should be done before proceeding further INSTALLATION HAND BOOK OF EXES 6000 EXES 6000 EX 610 620 INSTALLATION HAND BOOK OF EXCHANGE 133 21 10...

Page 4: ...Not yet available for sale Build this unit in all exchanges connected by tie line It is not possible to originate a conference from a station connected to the exchange without the CL unit but possible...

Page 5: ...ion LM 62 is also mountable Zone 0 7 with All Call Paging Tie line Interface Unit TI 62 Perforated Panel PF 022G Data Transmitting Unit DT E11 In the standard system Perforated Panel PF 012G should co...

Page 6: ...data Audio Signal Call Station Station 2 Number of stations paging zones and links Composition of exchange s Maximum number of links within own exchange EX 610 EX 620 Maximum number of links between t...

Page 7: ...5 6 7 8 Station No 200 207 208 215 216 223 224 231 232 239 240 247 248 255 256 263 LM 9 10 11 12 13 14 15 16 Station No 264 271 272 279 280 287 288 295 296 303 304 311 312 319 320 327 PI Note LM Line...

Page 8: ...ON You may not substitute the LM unit LM8 or LM16 for the PI unit EX 610 Max 48 stations EX 620 Max 112 stations The case where the paging call is unnecessary from the exchange without the PI unit to...

Page 9: ...on of tie line links between exchanges A and B is possible But in conside ration of possible increase in the number of exchanges to be connected from 2 to 3 in the future we suggest you connect 6 7 of...

Page 10: ...station Exchange A EX 620 Terminal board BX 620 Terminal board BX 620 Exchange B EX 620 YR 810 for stations YR 801 for Tie line YR 810 for stations YR 801 for Tie line The cables between the exchange...

Page 11: ...810 for stations YR 801 for Tie line Exchange A BX 620 T1 YR 810 for stations YR 801 for Tie line The cables between the exchanges 4 wires 4 links The cables between the exchanges 4 wires x 4 links Th...

Page 12: ...C About 8 days 40 C 8 We suggest you replace the soldered button battery GB50 3FA1 115 42 031 9 with the new one according to the following list that shows an expected life span of the battery Be sure...

Page 13: ...irmation tone will be heard 2 Clears function group A Confirmation tone will be heard 2 Clears function group B Confirmation tone will be heard 2 Clears function group C Confirmation tone will be hear...

Page 14: ...e dial receiving section of the CP also to check if the signal is correctly transmitted as dialed from the station to be tested 2 If you place all LINK SELECT switches 1 4 of SW A on the CP 63 in OFF...

Page 15: ...he call As Fig 1 and Fig 2 show in the exchanges which make calls the DL Link Number corresponds with Tl Tie line Link Number In the exchange which is called the Tie line Link Number of the Tl Unit is...

Page 16: ...s called Tl Tie line Link Number Tie line Link Fixed by Connection Cable between Exchanges After power switch is on Links are used in numerical order Note If the Tl Tie line Link which corresponds wit...

Page 17: ...ence and General Purpose Control Not used Not used Group Blocking Programmable Station Numbering Pager Not Activate OFF OFF Not Activate Not Activate Not Activate Activate Activate Activate Activate 1...

Page 18: ...all Transfer Paging during Normal Calls Call Transfer Paging during Normal Calls Paging Time Interval Adjustment before Paging Pre announcement Tone Paging Zones Capacity 45 21 Selectable Dial Operati...

Page 19: ...ng Calls Among Groups Group Blocking AllowingAccess to Paging Zones Programable Station Numbering Personal Number Single Digit Dialing RemoteResponse Func tion Code 40 41 42 45 46 50 51 52 53 54 56 57...

Page 20: ...700 Remarks The following standard station numbering schedules of the exchanges A B and C are obtainable Hardwired station number Operating for Programming First Station No of Exchange A 1 8 First di...

Page 21: ...ing Zone 70 The First Station No of the Zone The Last Station No of the Zone Group Blocking Establishment of Each Group Group No 1 6 The First Station No of the Group The Last Station No of the Group...

Page 22: ...Touch Executive Station No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To allow all the stations to have this function Touch Confirmation tone will be heard 10 times Be sure to...

Page 23: ...Station No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To allow all the stations to have this function Touch Confirmation tone will be heard 10 times 3 Re start at Step 1 when m...

Page 24: ...Touch Confirmation tone NO Release finished YES Return NOTES 1 To allow all the stations to have this function 3 Re start at Step 1 when mis dialing occurs All other registrations remain valid Touch...

Page 25: ...e NO Release finished YES Return NOTES 1 To allow all the stations to have this function Touch Confirmation tone will be heard 10 times 3 Re start at Step 1 when mis dialing occurs All other registrat...

Page 26: ...FF Allowed Station No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To allow all the stations to have this function Touch Confirmation tone will be heard 3 Re start at Step 1 when...

Page 27: ...ion Code 54 at No 200 Station 4 A call to Master Station from Handset or Hands free Handset Substation Master Sub Relationship Function Code 61 can be programmed into Handset Substation TL 600S or Han...

Page 28: ...owed Station No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To allow all the stations to have this function Touch Confirmation tone will be heard 3 Re start at Step 1 when mis d...

Page 29: ...d Station No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To allow all the stations to have this function Touch Confirmation tone will be heard 3 Re start at Step 1 when mis dial...

Page 30: ...FF Touch Allowed Station No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To allow all the stations to have this function Touch Confirmation tone will be heard 3 Re start at Step...

Page 31: ...ation No OFF Touch Confirmation tone NO Release finished Return NOTES 1 To allow all the stations to have this function Touch Confirmation tone will be heard 3 Re start at Step 1 when mis dialing occu...

Page 32: ...utive Station No Executive Station No Touch Confirmationtone NO Release finished YES Return NOTES 1 To release at one time the data programmed into all the stations for this function 3 Switch B 5 must...

Page 33: ...Registration finished YES NO Release YES Sub Station No Sub Station No Touch Sub Station No Sub Station No Touch Confirmation tone NO Release finished YES Return NOTES 1 To release at one time the da...

Page 34: ...Touch Original Station No Original Station No Touch Confirmation tone Release finished NO YES Return NOTES 1 To release at one time the data programmed into all the stations for this function Touch Co...

Page 35: ...for this function Touch Confirmation tone will be heard 2 Re start at Step 1 when mis dialing occurs All other registrations remain valid 3 Switch B 4 must be ON to employ this function 4 In the case...

Page 36: ...o of the Group Confirmation tone NO New Registration finished YES Return NOTES 1 To release at one time the data programmed into all the groups for this function Touch Confirmation tone will be heard...

Page 37: ...Last Station No of the Group Confirmation tone NO New Registration finished YES Return NOTES 1 To release at one time the data programmed into all the groups for this function Touch Confirmation tone...

Page 38: ...Registration finished YES NO Release YES Calling Group No 1 8 Touch NOTES 1 To release at one time the data programmed into all the groups for this function 3 Do not register a Group to call itself 4...

Page 39: ...Confirmation tone NO New Registration finished YES NO Release YES Touch Paging Zone 00 21 00 45 Touch Paging Zone 00 21 00 45 Confirmation tone NO Release finished YES Return NOTES 1 To release at one...

Page 40: ...YES Hardwired Station No Hardwired Station No Touch Hardwired Station No Hardwired Station No Touch NO Confirmation tone Release finished Return YES NOTES 1 To release all registered Programmed Stati...

Page 41: ...Any one Programmed Station No cannot be assigned to more than one Hardwired Station 3 CP DIP switch D 5 must be ON to employ this function Touch Confirmation tone will be heard 10 times C Restriction...

Page 42: ...A 5 Confirmation tone will be heard Clears function group B 6 Confirmation tone will be heard Clears function group C 7 Confirmation tone will be heard Clears function group D 8 Confirmation tone will...

Page 43: ...hange from among the followings 100 200 300 400 500 600 700 800 or 900 0 Without Calling Tone 1 Single tone 0 2 sec 2 Calling tone 0 3 sec 0 Without Paging Pre announcement Tone 1 Paging Pre announcem...

Page 44: ...nce Automatic Access to Paging Stations Allowed Access to One Shot Output Stations Allowed Access to Make Break Output Stations Allowed Access to 1 8 Select or Decimal Output Stations Allowed Access t...

Page 45: ...to Paging Stations Allowed Access to One Shot Output Stations Allowed Access to Make Break Output Stations Allowed Access to 1 8 Select or Decimal Output Stations Allowed Access to 4 Decimal Digits Ou...

Page 46: ...ations Allowed Access to One Shot Output Stations Allowed Access to Make Break Output Stations Allowed Access to 1 8 Select or Decimal Output Stations Allowed Access to 4 Decimal Digits Output Secreta...

Page 47: ...cation Lamp Type Calling Party Indication Name Group No 1 2 3 4 5 6 7 8 Note When the indication panel belongs to only one 1 station you should write the station number in both First Station No and La...

Page 48: ...No 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 8 16 9 17 10 18 11 19 12 20 13 21 14 22 23 24 25 26 27 28 29 30 15 31 16 32 17 33 18 34 19 35 20 36 21 37 38 39 40 41 42 43 44 45 Paging Group No 1...

Page 49: ...ge Paging Zone Type of Paging Dial Operation of Paging Response Zone Paging Station Paging or PA Paging Stations not belonging to any Zone Paging Response Possible Impossible Possible Stations in Each...

Page 50: ...T Annunciation Calling Party Indication etc and replace in the Unit Refer to 13 Explanation of Data Transmitting Unit Output Data Page 53 4 The DT E11 sends out 512 bit data 16 bit x 32 words to contr...

Page 51: ...10 DIP SWITCH TABLE FOR DATA TRANSMITTING AND RECEIVING UNITS CHANNEL SELECT Switch WORD SELECT Switch 50 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 52: ...3 4 units Calling Party Indication Lamp Type 2 YR 810 Terminal Board Stations Data Receiver Equipment using DR B61 Two wires In Out Annunciation Display Board YR 802 or YR 806 YR 803 VTR ITV etc Presc...

Page 53: ...egments LEDs 1 Make output 64 contacts are avail able for pager control 2 Max 120 Calling station numbers can be indicated when designated called station with Display Board is called The numbers of ca...

Page 54: ...nciation CHANNEL SELECT Switch Each Relay Output shows last 3 digits xxx of Personal Number WORD SELECT Switch Dial Operation Personal Number Registration Personal Number Cancellation Relay Make XXX 0...

Page 55: ...s CHANNEL SELECT Switch Example 1 One shot Make Output 2 Make Break Output 3 8 Selectable Make Output 4 Decimal Output 9 units Unit No 4 Condition 1 Unit No 6 Condition 8 Unit No 8 Condition 9 Binary...

Page 56: ...sl Channel 8 Stations Groups 2 Channels Total Number of Calling Stations Max 120 Stations Each Indication CHANNEL SELECT Switch Each Relay Output shows Calling Station No Note shows the Head of a Slid...

Page 57: ...Lamp of Indication Total Number of Station with Indications 4 Stations Groupsl Channel 8 Stations Groups 2 Channels Total Number of Calling Stations Max 120 Stations Each Indication CHANNEL SELECT Swi...

Page 58: ...xchange using the frame FR 510 or FR 520 allows for no tie line connection to the other exchange The tie line connections are only possible among the exchanges using the frame FR 510A FR 520A FR 510B...

Page 59: ...TOA ELECTRIC CO LTD KOBE JAPAN All manuals and user guides at all guides com...

Reviews: