background image

EXES-6OOO

Appearance and Dimensional Diagram

Note: Figure shows an example of the system with Conference, Tie-line, Paging and Data Transmitting functions.

1 Central Processing Unit CP-64

14 Extension Frame FR-631

2 Output Control Unit OC-62
3 Highway Control Unit HC-64
4 Signal Generating and Distributing Unit SG-62
5 Conference Link Unit CL-62A (In this location, DL-62A

is also mountable)

6 Duplex Link Unit DL-62A
7 Paging Interface Unit PI-62 (Type 1 in the left position,

type 2 in the right position)

8 Tie-line Interface Unit TI-62 (In this location, PI-62’s

are also mountable. Type 3 in the left position, type 4 in
the right position)

9 Station Paging Assignment Unit SA-64

10 Cabinet Rack CR-271
11 Main Frame FR-630
12 Line Modem Unit LM-62A
13 Jack for Programming Station

15 Data Transmitting Unit DT (When this unit is not used,

mount Perforated Panel PF-012G in this place.)

16 Power Supply Unit DS-630
17 DC Fuse 20A x 2 (129-256 stations)
18 AC Fuse 10A (110/120V), 5A (220/240V)
19 Power Indication LED lamp (green for AC operation, red

for battery operation)

20 Power Switch
21 Battery Case BC-630 (When this unit is not used,

mount the Perforated Panel PF-022G in this place.

22 Battery Fuse 10A x 3
23 Battery Power Switch

Note: PF-012G and PF-022G are standard accessories of the
DS-630.

Summary of Contents for EX-630

Page 1: ...2 WIRE INTERCOM SYSTEM EXES 6000 System Specifications Exchange EX 630 ...

Page 2: ...Composition The system is composed of three basic blocks 1 Exchange EX 630 2 Terminal Cabinet and Connecting Cables and 3 Stations 1 EX 630 Exchange a Central Processing Unit CP 64 b Output Control Unit OC 62 c Highway Control Unit HC 64 d Signal Generating Distributing Unit SG 62 e Duplex Link Unit DL 62A f 4 Units without CL 62A unit 3 Units with CL 62A unit Conference Link Unit 1 Conference Lin...

Page 3: ...gto the number of stations links and optional functions 2 shows either A or B is adaptable 3 shows Toa standard cable 4 shows one pair cable 5 shows two pair cable 6 It is possible to tie line between the EX 630 and the other exchanges EX 610 620 which are employing the CP 63 ...

Page 4: ... location PI 62 s are also mountable Type 3 in the left position type 4 in the right position 9 Station Paging Assignment Unit SA 64 10 Cabinet Rack CR 271 11 Main Frame FR 630 12 Line Modem Unit LM 62A 13 Jack for Programming Station 15 Data Transmitting Unit DT When this unit is not used mount Perforated Panel PF 012G in this place 16 Power Supply Unit DS 630 17 DC Fuse 20A x 2 129 256 stations ...

Page 5: ...C 121 Surface Mounted type Back Box for HF 630M S HF 631 M S g YC 150 Flush Mounted type Back Box for HF 640S CU 62 h YC 150E Flush Mounted type Back Box for HF 640S CU 62 i YS 13 Surface Mounted type Back Box for HF 640S CU 62 j PAM 05 Booster Amplifier 5W for HF 650M k DS 100 DC Power Supply Unit for PAM 05 HF 650M CU 62 I YC 024 Surface Mounted Bracket for HF 660M m TK 12 Talk Back Unit n CU 62...

Page 6: ...ssion by FM Signal From Station to Exchange 27 dBm Power Supply Unit Dark Brown Refer to Function Specifications system composition for CP 64 for functions and Maximum Output Signal Level 30 dBm Input and Output Base Band 200 Hz 5 kHz Transmission Band FM Carrier Band 15 kHz 35 kHz Noise Level 40 dBm or less Crosstalk 60 dB or less 1 5 kHz Speech Gain 30 dB 3 dB 1kHz Subscriber Insulation Resistan...

Reviews: