9
A L C 1
0 d B
M E T E R
A N C 1
O F F
S
1
2
The signal level of the highlighted channel is displayed by the
INPUT LEVEL, OUTPUT LEVEL, and ALC LEVEL indicators. The
selected channel moves cyclically among S (SENSOR level), 1
(Channel 1), and 2 (Channel 2) as the Meter indication selector
key is pressed.
Indicates ALC and ANC levels or their OFF states.
6.1.2. On-screen indications
[ALC/ANC level indication screen]
Displayed when in normal operation state.
[Setting screen]
G A T E
L E V E L
I N P U T 2
– 6 0 d B
Appears when there is a previous screen.
Displays the setting items.
Appears when there is a next screen.
Displays the setting content or value.
Varies as the PARAMETER knob is rotated.
I N P U T
S E N S E
S E T
P U S H
E N T E R
Press the PUSH-ENTER knob when this indication is displayed.