5. NOMENCLATURE AND FUNCTIONS

[FRONT PANEL]

DP-0202

DP-0204

Input level meter

 [INPUT LEVEL]

Output level meter

 [OUTPUT LEVEL]

These meters display the I/O levels. The topmost point

is a digital full scale (clipping point), and is +24dB in

terms of analog. The dynamic range of indication is

60dB. Adjust the volume control to a point where

program source dynamic peaks remain just within the

range of the level indicator LEDs and do not cause the

clipping indicator to flash on.

Power switch

Set this switch to ON and the processor starts operating

in the status it was in just before the power was last

turned OFF. The power LED lamp lights at this time.

Muting button [MUTE]

This  button is used to disconnect output signals to stop

sound. If this button is pressed, the output is muted and

its corresponding LED lamp lights.

Master unit indicator [MASTER]

The unit in which the ID number is set to "1" (LED lamp

lights) functions as a master unit when switching

between stored information. For details, refer to p.8

"7. UNIT ID NUMBER SETTING".

Overflow indicator

 [OVERFLOW]

This lamp lights when the internal digital signal

processor overflows for equalizing or filtering  operation.

Digital input signal operation indicators

DIGITAL IN : Lights when the input mode is set for

digital signal.

RUN 

: Lights when a digital signal is input

correctly.

EMPHASIS : Lights when EMPHASIS information is

received.

ERROR : 

Lights when there is an error in digital

signals.

Memory call key [MEMORY]

This key is used to recall the memory pattern selected

with the memory/unit number selection key.

Unit ID number indication key [UNIT ID]

This key is used to show the unit ID number on the

display.

Memory/unit ID number display

[MEMORY/UNIT ID]

Either the memory number or unit ID number is

displayed. Usually, the selected memory number is

displayed.

Memory/unit ID number selection key

The memory number or unit ID number can be selected

with the UP and DOWN keys.

Pocket  cover

3

Summary of Contents for DP-0202

Page 1: ...HE USER THAT IMPORTANT OPERATING AND SERVICING INSTRUCTIONS ARE IN THE PAPERS WITH THE APPLIANCE CONTENTS 1 GENERAL DESCRIPTION 2 6 PERSONAL COMPUTER CONNECTIONS 6 7 2 FEATURES 2 7 UNIT ID NUMBER SETTING 8 3 HANDLING PRECAUTIONS 2 8 USING THE MEMORY I O CONNECTOR 9 4 SIGNAL PROCESSING FUNCTION 2 9 RECALLING THE PATTERN MEMORIES 10 5 NOMENCLATURE AND FUNCTIONS FRONT PANEL 3 10 SPECIFICATIONS 11 FRO...

Page 2: ...ing up to 30 units A system locking function prevents problems resulting from operation error Multiple signal processing functions yet space saving design sized for 19 rack Wide operating voltage range 90 VAC 250 VAC 2 IN 2 OUT DP 0202 and 2 IN 4 OUT DP 0204 3 HANDLING PRECAUTIONS The digital processor has no parameter setting functions so you use a personal computer and the dedicated TOA software...

Page 3: ...e ID number is set to 1 LED lamp lights functions as a master unit when switching between stored information For details refer to p 8 7 UNIT ID NUMBER SETTING Overflow indicator OVERFLOW This lamp lights when the internal digital signal processor overflows for equalizing or filtering operation Digital input signal operation indicators DIGITAL IN Lights when the input mode is set for digital signal...

Page 4: ...SUB connector can be used Use RS 485 when controlling multiple units XLR connectors for RS 485 are mounted on the back of the unit System locking switch LOCK Use this switch to set how the hardware is locked OFF All functions are available unlocked such as memory switching 1 All functions are locked except memory switching 2 All front panel facilities are locked Make sure the power is switched ON ...

Page 5: ...t RS 485 A 3 pin XLR connector for RS 485 communications This connector can only be used when the communications port selection switch located in the front pocket is set to RS 485 When simultaneously controlling two or more units use this port and connect each unit in turn A mode conversion adaptor is required because data are usually transmitted from a personal computer in RS 232C mode For detail...

Page 6: ... In this case use the communications method called RS 232C Set the communications port selection switch in the front pocket to RS 232C As shown in Fig 1 connect a straight cable from the PC s RS 232C port to the DP 0202 s DP 0204 s connector for RS 232C communications Either the connector in the front pocket or on the rear panel may be used both are 9 pin D SUB connectors and are connected in para...

Page 7: ...ctor for RS 485 communications via the adaptor Similarly make connections for the second unit and its subsequent units as shown in Fig 2 Since the settings made through the PC can be stored in each unit s memory the set patterns can be recalled if only units are connected as shown in Fig 2 the adaptor and computer are not necessary to recall the patterns In this case the unit with ID No 1 acts as ...

Page 8: ...e lever of the unit ID number setting switch to the right 4 While holding the lever operate the front mounted memory unit number selection key to show the desired number on the memory unit number display 5 Push the unit ID number indication key to register the number being displayed 6 Release the unit ID number setting switch Notes The ID number is factory preset to No 1 Make sure the same number ...

Page 9: ...memory selection status can be output to external equipment by making the connector s pin No 2 a high level Table 2 shows the relationship of selected memory to each pin s output status Note No connection is possible for the pin 2 CTRL input shown in Table 2 This pin is pulled up at 5V Pin arrangement of the memory I O connector Memory No 1 Memory No 2 Memory No 3 Memory No 4 Memory No 5 Memory No...

Page 10: ...1 acts as a master unit to recall the same pattern memory of all connected units Follow the procedures below to recall pattern memories when the DP 0202 or DP 0204 is a master unit 1 Push the front mounted memory unit ID number selection key to show the desired memory number on the display The displayed number will flash 2 Push the memory recall key to recall the selected pattern memory The displa...

Page 11: ...202 2 IN 4 OUT DP 0204 AES EBU format sampling frequency 48 kHz XLR 3 31 3 32 type connector 20 bits 20 bits 48kHz At least105dB IHF A 20 20 kHz 0dB 1dB Less than 0 05 at 1 kHz 4 dB Less than 80 dB at 1 kHz 16 presets 0 6dB 0 6dB 12 dB OFF 1 2 7 point LED 7 point LED Double digit LED Provided for each output Green LED Red LED DIGITAL IN RUN EMPHASIS ERROR Single unit control RS 232C 9 pin D SUB co...

Page 12: ...11 APPEARANCE TOA Corporation Printed in Japan 133 12 288 2A ...