10. SPECIFICATIONS
Power requirements
Input/output
Analog signal input
Analog signal output
Digital input/output
AD converter
DA converter
Sampling frequency
Dynamic range
Frequency response
Total harmonic distortion
Closstalk
Preset memories
Input booster
Output attenuation
System lock
Input level meter
Output level meter
Memory No. /unit ID No. indication
Muting switch
Master indication
Overflow indication
Digital input operation indication
Communication
Control input
Control output
Word clock input
Control software
Dimensions
Weight
Color
Standard Accessoris
AC 100 V- 240 V, 50/60HZ, 36 W
2 I N / 2 OUT (DP-0202)
2 IN/ 4 OUT (DP-0204)
AES/EBU format, sampling frequency 48 kHz, XLR-3-31 , 3-32 type connector
20 bits
20 bits
48kHz
At least105dB (IHF-A)
20- 20 kHz +0dB, -1dB
Less than 0.05 % at 1 kHz, +4 dB*
Less than -80 d B at 1 kHz
16 presets
0, +6dB
0, -6dB, -12 dB
OFF, 1,2
7-point LED
7-point LED
Double digit LED
Provided for each output
Green LED
Red LED
DIGITAL IN, RUN, EMPHASIS, ERROR
Single unit control : RS-232C, 9-pin D-SUB connector
System control :
RS-485,
XLR-3-31,
3-32
type
connector
External memory selection by make contact
Output of memory selection status (TTL level)
Corresponding to MS-Windows
483 (W) x 44 (H) x 327.7 (D) mm (19.0 x 1.7 x 12.9 in.), 1
-size
(EIA)
5kg (11 Ib.)
Black
AC power cord .................. 1
Rack mounting screw ....... 4
Operating instructions ....... 1
AC fuse ............................. 1
* 0 dB is referenced to 0.775 V RMS.
Specifications are subject to change without notice.