• Avoid installing the unit in humid or dusty locations,

in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock. 

• To avoid electric shocks, be sure to first turn off this

unit's power switch when connecting speakers.

• The unit is designed exclusively to be mounted in

an equipment rack. Be sure to follow the
instructions below when rack-mounting the unit.
Failure to do so may cause a fire or personal injury.
· Install the equipment rack on a stable, hard floor.

Fix it with anchor bolts or take other arrangements
to prevent it from falling down.

· The supplied rack-mounting screws can be used

for the TOA equipment rack only. Do not use
them for other racks.

· When installing the unit in a rack other than that

of TOA, be sure to use the screws with a
diameter of over 5 mm and length of over 12 mm
to mount the unit.

· When connecting the unit's power cord to an AC

outlet, use the AC outlet with current capacity
allowable to the unit.

When the Unit is in Use 

• Make sure to set all input level controls to 

(infinity)

position before power is switched on. 
Loud noise produced when power is switched on
with any of those controls set to the position other
than 

position can impair hearing. 

• Do not operate the unit for an extended period of

time with the sound distorting. Doing so may cause
the connected speakers to heat, resulting in a fire.

• Contact your TOA dealer as to the cleaning. If dust

is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result. 

• If dust accumulates on the power supply plug or in

the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.

• Turn off this unit's power switch, and unplug the

power supply plug from the AC outlet for safety
purposes when cleaning or leaving the unit unused
for 10 days or more. Doing otherwise may cause a
fire or electric shock. 

2. GENERAL DESCRIPTION

TOA's DA-250D and DA-250DH Dual Power Amplifiers feature high power handling capabilities and durability.
The DA-250D is configured with 250 W x 2 channels (4 

Ω

output) and 170 W x 2 channels (8 

Ω

output), and

the DA-250DH features a 250 W x 2 channels (100 V line, 40 

Ω

output) configuration. Besides, the DA-250D's

output is made available for bridge connection, allowing it to be used as a 500 W (8 

Ω

) monaural amplifier.

Their wide range of applications include stores and permanent sound systems. 

3. FEATURES

• 1U rack mounting size*.
• Low power consumption and light weight.
• An input signal to Channel 1 can be routed to both channels 1 and 2, and the output level adjusted using the

input level control for each channel. 

• Electronically-balanced inputs.
• Input terminals employ removable terminal blocks and XLR type connectors to provide maximum connection

ease. 

• Equipped with the LED indicators that show the input/output status, etc. 
• Built-in protection circuitry disconnects the power amplifier's output from the load when a short circuit,

overload, or unusual temperature rise occurs. 

* 1U size = 44.5 mm (reference size)

The lighting flash with arrowhead symbol,
within an equilateral triangle, is intended
to alert the user to the presence of
uninsulated "dangerous voltage" within
the product's enclosure that may be of
sufficient magnitude to constitute a risk of
electric shock to persons.

Summary of Contents for DA-250D

Page 1: ...l Power Amplifier Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment OPERATING INSTRUCTIONS An all pole mains switch with a contact separation of...

Page 2: ...AND CONNECTIONS 7 1 Switch Settings and Speaker Connections 7 1 1 When using the DA 250D 8 7 1 2 When using the DA 250DH 9 8 REMOVABLE TERMINAL PLUG CONNECTION 10 9 PROTECTION OPERATION LIST 11 10 TA...

Page 3: ...ed service personnel Do not place cups bowls or other containers of liquid or metallic objects on top of the unit If they accidentally spill into the unit this may cause a fire or electric shock Do no...

Page 4: ...may result If dust accumulates on the power supply plug or in the wall AC outlet a fire may result Clean it periodically In addition insert the plug in the wall outlet securely Turn off this unit s po...

Page 5: ...e such volatile liquids could deform or discolor the unit 5 INSTALLATION PRECAUTIONS The supplied power supply cord is designed for exclusive use with this unit Never use it with other equipment When...

Page 6: ...vel exceeds about 20 dB Output indicator OUTPUT Lights yellow when an output level exceeds about 1 W at an 8 load DA 250D or 40 load DA 250DH Peak indicator PEAK Lights red when an output signal clips...

Page 7: ...mode Set BRIDGE switch to ON Note Be sure to first turn off the Power switch 1 when changing these switch settings 10 CH 1 mode ON OFF switch PARALLEL ON OFF Setting this switch to ON transmits the Ch...

Page 8: ...utput terminals 4 4 Replace the output terminal cover in place Be sure to replace the unit s terminal cover after connection completion Because high voltage is generated at the speaker output terminal...

Page 9: ...CH1 CH1 CH2 CH2 1 input 2 outputs 2 inputs 2 outputs factory preset 40 40 40 40 Speaker output terminals 8 CH2 CH1 Speaker output terminals Switch BRIDGE CH 1 mode OFF ON Setting 4 8 4 8 CH1 CH1 CH2...

Page 10: ...sens Terminal screw Slotted screwdriver Shielded cable Removable terminal plug Hot Cold Earth 1 1 2 Bit shape 3 mm 8 REMOVABLE TERMINAL PLUG CONNECTION Cautions Be sure to use shielded cables for audi...

Page 11: ...operation Short circuit Current limiter activated Load is disconnected Protection indicator lights Check speakers and lines for short circuit Temperature rise at power amp heat sink over 100 C Load di...

Page 12: ...the figure Step 3 Detach the filter inside the ventilation panel Step 4 Clear the filter of dust Step 5 Replace the filter and ventilation panel Ventilation Panel 2 3 Filter Ventilation Panel Detach...

Page 13: ...uit Current Limiter Short Detector Protection Circuit H H E C C CH 1 INPUT E H H E C C CH 2 INPUT E 13 BLOCK DIAGRAMS 13 1 DA 250D 13 2 DA 250DH PARALLEL switch OUTPUT 1 relay CH 1 OUTPUT CH 2 OUTPUT...

Page 14: ...C temperature rise inside the unit over 80 C 100 dB A weighted 70 dB A weighted Power blue x 1 Input green x 2 Output yellow x 2 Peak red x 2 Protect red x 2 Forced air cooling 10 C to 40 C Under 90 R...

Page 15: ...etween barriers 8 8 mm 50 20 000 Hz 3 dB 1 dB 0 1 1 kHz 0 3 100 20 000 Hz Protection against excessive current flow due to overload short circuit unusual DC voltage output temperature rise at power am...

Page 16: ...raceability Information for Europe EMC directive 2004 108 EC Manufacturer TOA Corporation 7 2 1 Minatojima Nakamachi Chuo ku Kobe Hyogo Japan Authorized representative TOA Electronics Europe GmbH Sued...

Reviews: