![Toa DA-250D Operating Instructions Manual Download Page 13](http://html1.mh-extra.com/html/toa/da-250d/da-250d_operating-instructions-manual_1122266013.webp)
13
OUTPUT 1
relay
CH 1
OUTPUT
CH 2
OUTPUT
+4 dB
-10 dB
CH 1 sensitivity
selection jumper
(+4 dB/-10 dB)
CH 1
input level
control
+4 dB
-10 dB
CH 2 sensitivity
selection jumper
(+4 dB/-10 dB)
CH 2
input level
control
ON
OFF
BRIDGE ON/OFF
switch
+
-
BRIDGE
OUTPUT
OUTPUT 2
relay
+
-
PARALLEL
switch
Current Limiter
Short Detector
Protection Circuit
Current Limiter
Short Detector
Protection Circuit
H
H
E
C
C
CH 1 INPUT
E
H
H
E
C
C
CH 2 INPUT
E
13. BLOCK DIAGRAMS
13.1. DA-250D
13.2. DA-250DH
PARALLEL
switch
OUTPUT 1
relay
CH 1
OUTPUT
CH 2
OUTPUT
+4 dB
-10 dB
CH 1 sensitivity
selection jumper
(+4 dB/-10 dB)
CH 1
input level
control
+4 dB
-10 dB
CH 2 sensitivity
selection jumper
(+4 dB/-10 dB)
CH 2
input level
control
+
-
OUTPUT 2
relay
+
-
Current Limiter
Short Detector
Protection Circuit
Current Limiter
Short Detector
Protection Circuit
H
H
E
C
C
CH 1 INPUT
E
H
H
E
C
C
CH 2 INPUT
E