background image

12-9 Channel 

(CH. 

8)  Calling 

Party 

Indication 

Lamp 

Type 

(1)

Each "Calling Station" or "Waiting Station" is shown by Each  Lamp of Indication.

Total  Number of Station  with  Indications : 4 Stations/Channel  (8 Stations/2 Channels)

Total Number of Calling Stations : Max. 128 Stations/Each Indication

Exchange

Data Transmitter

Data Receiver

Relay Output No.

Each Relay Output shows

"Calling Station No."

Note:

shows the  Head of a Slide Switch

-   47   -

Summary of Contents for CPU-55

Page 1: ...INTERCOM SYSTEM TOA EXES 5000 INTERCOM SYSTEM EXES 5000 CPU 55 Central Processing Unit CPU 55 INSTALLATION HAND BOOK TOAELECTRICCO LTD KOBE JAPAN 133 21 005 5...

Page 2: ...t p u t 6 8 Stations Allowed Access to 4 Decimal Digits Output FUNCTION CODE 50 12 51 13 52 14 53 15 56 16 57 17 58 18 59 19 Function Group B 6 9 Secretary T r a n s f e r 60 6 10 Master Sub Relation...

Page 3: ...t s 11 Explanation of Data Transmitting Unit Output Channels 12 Explanation of Data Receiving Unit Output C h a n n e l s Page 28 28 29 30 31 32 32 33 34 35 36 38 39 39 40 41 42 43 44 45 46 47 48 12...

Page 4: ...005 5 This Hand Book DATA TRANSMITTING AND RECEIVING UNIT Or DT E11 OPERATION MANUAL 133 05 094 1 DR B61 OPERATION MANUAL 133 05 095 0 SYSTEMS OF EXES 5000 System using CPU 55 System with Display and...

Page 5: ...PIU is required 3 Wiring of Station Paging Assignment Plug is required Connection of all call signal on 2 PIUs 1 For EX 510 64 stations Connect P0 and 256 2 For EX 520 128 stations Connect PO and 312...

Page 6: ...e some other functions may not work properly 7 The Ni Cd battery GB50 3FA1 is capable of saving im portant memory registration data even at times of power failure and we suggest you replace it at leas...

Page 7: ...n the exchange Look at indication of LINE ADDRESS of HCU 14 LEDs and SIGNAL CODE indication 4 LEDs All LED lamps are out SIGNAL CODE indication F 4 2 1 Memory is normal Some errors in memory Lighted l...

Page 8: ...tion group C Confirmation tone will be heard Clears function group D Confirmation tone will be heard Clears function group E Confirmation tone will be heard Clears personal numbers and single digit di...

Page 9: ...t to select No 15 Fig 1 3 2 Check of CMOS RAM Programmed data memory At the time of initial programming and registration using station No 200 1 You hear calling tone instead of confirmation tone if th...

Page 10: ...n links are used in numerical order for each communication Remember this to help you when problems are found with specific links Remarks 1 Be sure to avoid mistake at time of DIP switch installation a...

Page 11: ...EX 510 Paging Pre announce Tone Duration Selection Emergency All Call Paging Priority Combination Paging 15 Individual Paging Zones 2 Digit Dialing 20 99 1 Sec Activate 15 Zones Activate 2 Sec Not Ac...

Page 12: ...Station No 200 327 20 99 Station No 200 327 20 99 Station No 200 327 20 99 Station No 200 327 20 99 Station No 200 327 20 99 Station No 200 327 20 99 Station No 200 327 20 99 Station No 200 327 20 99...

Page 13: ...OFF Touch Executive Station No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To register all stations at one time Touch 10 times Confirmation tone will be heard 2 To release all...

Page 14: ...h Continuously Called Station No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To register all stations at one time Touch 10 times Confirmation tone will be heard 2 To release all...

Page 15: ...Allowed Station No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To register all stations at one time Touch 10 times Confirmation tone will be heard 2 To release all registered st...

Page 16: ...F Touch Confirmation tone NO Release finished YES Return NOTES 1 To register all stations at one time Touch 10 times Confirmation tone will be heard 2 To release all registered stations at one time To...

Page 17: ...tion No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To register all stations at one time Touch 10 times Confirmation tone will be heard 2 To release all registered stations at o...

Page 18: ...n No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To register all stations at one time Touch 10 times Confirmation tone will be heard 2 To release all registered stations at one...

Page 19: ...llowed Station No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To register all stations at one time Touch 10 times Confirmation tone will be heard 2 To release all registered sta...

Page 20: ...Station No OFF Touch Confirmation tone NO Release finished YES Return NOTES 1 To register all stations at one time Touch 10 times Confirmation tone will be heard 2 To release all registered stations a...

Page 21: ...finished YES Release NO YES Executive Station No Executive Station No Touch Executive Station No Executive Station No Touch Confirmation tone NO Release finished YES Return NOTES 1 To release all regi...

Page 22: ...stration finished YES Release NO YES Sub Station No Sub Station No Touch Sub Station No Sub Station No Touch Confirmation tone NO Release finished YES Return NOTES 1 To release all registered stations...

Page 23: ...tion No of the Zone Last Station No of the Zone Touch Confirmation tone NO New Registration finished YES Return NOTES 1 To release all registered Zones at one time Touch 10 times Confirmation tone wil...

Page 24: ...o of the Group Last Station No of the Group Touch Confirmation tone NO New Registration finished YES Return NOTES 1 To release all registered Zones at one time Touch 10 times Confirmation tone will be...

Page 25: ...mation tone NO New Registration finished YES Release NO YES Combination Paging Zone No 90 99 Touch Combination Paging Zone No 90 99 Touch Confirmation tone NO Release finished YES Return NOTES 1 To re...

Page 26: ...h Confirmation tone NO New Registration finished YES Release NO YES Calling Group No 1 8 Touch Calling Group No 1 8 Touch Confirmation tone NO Release finished YES Return NOTES 1 To release all regist...

Page 27: ...8 max 8 Confirmation tone NO New Registration finished YES Release NO YES Touch Touch Confirmation tone NO Release finished YES Return NOTES 1 To release all registered Paging Zones at one time Touch...

Page 28: ...NO Release finished YES Return 1 Hardwired Station Number 200 327 20 99 2 Programmed Station Number 200 999 20 99 NOTES 1 To release all registered Programmed Station No at one time Touch 10 times Co...

Page 29: ...ations Allowed Access to All Call Stations Allowed Access to Conference Stations Allowed Access to One Shot Make Output Stations Allowed Access to Make Break Output Stations Allowed Access to 1 8 Sele...

Page 30: ...to Conference Stations Allowed Access to One Shot Make Output Stations Allowed Access to Make Break Output Stations Allowed Access to 1 8 Select or Decimal Output Stations Allowed Access to 4 Decimal...

Page 31: ...to Conference Stations Allowed Access to One Shot Make Output Stations Allowed Access to Make Break Output Stations Allowed Access to 1 8 Select or Decimal Output Stations Allowed Access to 4 Decimal...

Page 32: ...s to All Call Stations Allowed Access to Conference Stations Allowed Access to One Shot Make Output Stations Allowed Access to Make Break Output Stations Allowed Access to 1 8 Select or Decimal Output...

Page 33: ...ble Combination Paging Table Station Paging Zone Department No 1st Station No Last Station No Selected Paging Zone Combination PagingZone Function Code 70 For Paging Priority For Paging Response Depar...

Page 34: ...Last Station No No 1 2 3 4 5 6 7 8 Calling Group No Others Paging Zone Department All Call Paging Group No Others Individual Paging Zones Function Code 82 Combination Paging Zones Called Group No Oth...

Page 35: ...channel select switches located on the printed circuit board according to the necessary functions such as IN OUT Annunciation Calling Party Indication etc and replace in the Unit Refer to 12 Explanati...

Page 36: ...T OF DATA TRANSMITTING AND RECEIVING UNIT Exchange Data Transmitter Data Receiver Relay Output No Each channel output of DT E11 may be connected to DR B61 s as above for CH 0 Note shows the Head of a...

Page 37: ...arty with Indicator No 216 231 Calling Party Display Board 1 Station 1 lamp Indication Called Party with Indicator No 232 235 Called Party with Indicator No 236 239 In Out Annunciations 500 contacts M...

Page 38: ...Parties No 201 No 215 No 216 Calling Party Waiting Party Nos of WaitingParties No 217 16 units No 231 No 232 4 units 1 call 1 lamp Maximum indications 128 calls No 233 No 234 No 235 No 236 4 units 1 c...

Page 39: ...Make output 240 contacts are available for pager control 10 Selectable Decimal Outputs are available with 7 segments LEDs One contact out of 8 selectable make output is obtained When a station with a...

Page 40: ...CEIVING UNIT OUTPUT CHANNELS 12 1 Channel 0 CH 0 In Out Annunciation Dial Operation Personal Number Registration Personal Number Cancellation Note shows the Head of a Slide Switch Data Receiver Relay...

Page 41: ...ake Break Output Dial Operation Exchange Data Transmitter Relay Make XXX 000 511 512 contacts Relay Break Data Receiver Relay Output No Each Relay Output shows Relay Contact Number Note shows the Head...

Page 42: ...hot Make Output Dial Operation Exchange Data Transmitter Data Receiver Relay Make min 1ms max 2ms XXX 000 499 500 contacts Relay Output No Each Relay Output shows Relay Contact Number Note shows the H...

Page 43: ...No 8 Condition 9 Binary Negative Logic Output 3 8 Selectable Make Output Unit No 4 Condition 0 Unit No 6 Condition 7 1 Relay Make 0 Relay Break 4 Pager Control Output Pager No 127 is being called Eac...

Page 44: ...peration Exchange Data Transmitter Example Unit No 24 Condition 3 Binary Negative Logic 3 Data Receiver XX 01 99 Y 0 9 Relay Output No Unit No 48 Condition 0 Binary Negative Logic 0 1 Relay Make 0 Rel...

Page 45: ...Selectable Make Output 64 Units Dial Operation Exchange Example Unit No 8 Condition 0 Unit No 10 Condition 7 Data Receiver Relay Output No xx 01 64 Y 0 7 1 Relay Make 0 Relay Break Note shows the Head...

Page 46: ...Output No Example d c Digit of Calling Station No d w Digit of Waiting Station No t n w Total Number of Waiting Station logic Binary negative logic 1 Relay Make 0 Relay Break Note shows the Head of a...

Page 47: ...Waiting Station Total Number of Station switch Indications 16 stations Channel Data Receiver Relay Output No Exchange Data Transmitter Example d c Digit of Calling Station No d w Digit of Waiting Sta...

Page 48: ...ach Lamp of Indication Total Number of Station with Indications 4 Stations Channel 8 Stations 2 Channels Total Number of Calling Stations Max 128 Stations Each Indication Exchange Data Transmitter Dat...

Page 49: ...tions 4 Stations Channel 8 Stations 2 Channels Total Number of Calling Stations Max 128 Stations Each Indication 12 10 Channel 9 CH 9 Calling Party Indication Lamp Type 2 Exchange Data Transmitter Dat...

Page 50: ...TOAELECTRICCO LTD Printed in Japan...

Reviews: