![Toa C-RM700 Operating Instructions Manual Download Page 10](http://html1.mh-extra.com/html/toa/c-rm700/c-rm700_operating-instructions-manual_1122989010.webp)
10
[Rear]
[Bottom surface] Note:
Function indications (Silk printed) on the bottom surface
TERMINATION
(RM CTRL)
OFF
ON
CAMERA
RIMOTE
SWITCHER
GND -
+
GND -
+
GND -
+
ALARM IN
ALARM OUT
12V
IN
Switcher control terminals (RS-485)
Connect to the Multi-Switcher's dedicated remote
control terminal, and control the Switcher's
screen display.
Slave remote controller terminal termination
switch
Set to ON during normal use.
Alarm input terminal (RS-232C)
Connects to an alarm input unit to receive alarm
information.
Alarm output/Control input terminal
Closing the contact corresponding to the alarm
activated channel (camera number).
AC adapter power input terminal [12 V DC IN]
Insert the DC plug of the dedicated AC adapter
into this terminal.
Auto key
*2
Enables or disables the Combination camera's
automatic functions (Auto-Pan, Auto-Trace, and
Preset Sequence). The Auto key can only be
used when the Control key is lighting.
Auto-Pan: Automatically rotates the camera
horizontally.
Auto-Trace: Stores manual camera operations to
the Combination camera, and
automatically reproduces such
operations stored in memory.
Preset Sequence: Automatically reproduces the
camera images in the order of
preset position numbers.
Tour: Stores the preset and trace performed at
each camera in the order of desired
reproduction number, and automatically
reproduces such operation.
Joystick
*2
Used to move up, down, left, or right and zoom
in/out the camera with pan/tilt head connected to
the system. The joystick can only be used while
the Control key is lighting.
Cable holder
Used to bundle the cables.
Camera control terminals (RS-485)
Connect to the Combination camera.
Slave unit remote control terminals
Connect to another C-RM700 to be designated
as a slave unit for remote control from different
locations.