Keep wires as far as possible from a heater
(C-CH100FH only) because fires or electric
shock could result.
To avoid burns, do not touch a heater
(C-CH100FH only).
Be sure to use an optional 24 VAC adapter (CC-5941B) for 24 VAC power.
Failure to do this could cause fires.
8
8. CONNECTIONS
①
Base
Heater (C-CH100FH only)
Orientation of lens
Note: Power must be switched on after connection completion.
Fan (not mounted in the C-CH100)
Power input terminal block
⑫
Cord entry bushing
⑪
Cord entry bushing
8.1. When not Using a Pan/Tilt Drive
Connect the power input terminal block inside the housing's rear panel as follows.
8.1.1. C-CH100FH
The 24 VAC terminal functions as a terminal to relay the 24 VAC camera's power. Switching on the power
after connecting the 24 VAC cable supplies the power to a fan and a heater.
• When connecting the 24 VAC camera
• When not connecting the 24 VAC camera
Grounding line 24 VAC power line
To 24 VAC camera's
terminal block
Grounding line
24 VAC power line
8.1.2. C-CH100
The use of the power input terminal block facilitates connections when using the 24 VAC camera. The
terminal block is not used when the connected camera is not of the 24 VAC type.
• When relaying the 24 AC camera
• When not relaying the 24 VAC camera
24 VAC power line
To 24 VAC camera's
terminal block
No wiring is required.
Caution