5. CONNeCTION eXAMPLeS

Bluetooth

®

LCD

AM – CF1

HDMI

USB

LAN

USB

PC

Webcam

Polycom

Control In/Out

3rd party

controls

Video

Conference

System

AUX IN

AUX OUT

Codec In/Out

PoE Extender

(DC 52V)

AC Adapter

(DC 12V)

Mixer/

Amplifier

Sound

Source

Device

6. INSTALLATION

Follow the procedures below to mount the AM-CF1 unit to a wall:

Be sure to use the following wall mounting brackets and screws. If 

hardware other than that mentioned below is used, the unit could fall 

down, potentially resulting in damage and personal injury.

WARNINg

 Step 1. Remove the 4 screws fixing the wall mounting bracket as illustrated below and detach the bracket from 

the AM-CF1 unit.

 Step 2. Attach the wall mounting bracket to a wall.

Separately prepare anchor bolts and other hardware needed for 

wall mounting.

A

6

 Step 3. Hook the unit’s lower mounting tab (A in the figure at right) 

into the mounting bracket mounted on the wall. 

 Step 4. Make necessary connections.

For connection method, see p. 9.

 Step 5. Bind connected wires using a tying tool or the like.

 Step 6. After connection is completed, tilt the unit upward with the 

tab hooked in Step 3 as a supporting point.

 Step 7.  If the upper tab (B in the figure at right) contacts the bracket on the 

wall, shift the unit slightly upward and hook the upper tab to the 

bracket on the wall.  

 Step 8. Secure the unit to the bracket using the screws removed in Step 1.

Note

Screws can be installed not only from the upward direction, but 

also from the side or downward direction.

7. CONNeCTIONS

7.1. AC Adapter Connection

Connect the AC adapter*

1

 to the AM-CF1’s power input terminal.

*

1

 Use the AC adapter with the following specification. 

AC adapter

For AC adapters, use the adapter with the 

designated specification. 

The use of other adapters could result in fire or 

other possible damage.

CAUTION

[Usable AC adapter]

Output : 12 V DC, 5 A, positive tip polarity

7.2. Network Connection

The AM-CF1 automatically distinguishes between 10BASE-T and 100BASE-TX networks and establishes a 

connection. For this connection, use a straight UTP Category 5 or greater LAN (Ethernet) cable terminated with 

an RJ-45 connector.

B

From PoE Extender

Summary of Contents for AM-CF1

Page 1: ...rated Audio Collaboration System AM CF1B AM CF1W Thank you for purchasing TOA s Integrated Audio Collaboration System Please carefully follow the instructions in this manual to ensure long trouble fre...

Page 2: ...7 8 Removable Terminal Plug Connection 12 8 SYSTEM SETTINGS 13 8 1 Overview of System Settings 13 8 2 System Requirements 13 8 3 Connections 13 9 OPERATION 14 9 1 Turning Power ON and OFF 14 9 2 Swit...

Page 3: ...e the unit is designed for indoor use do not install it outdoors If installed outdoors the aging of parts causes the unit to fall off resulting in personal injury Also when it gets wet with rain there...

Page 4: ...e that the use of other adapter may cause a fire If dust accumulates on the power supply plug or in the wall AC outlet a fire may result Clean it periodically In addition insert the plug in the wall o...

Page 5: ...Industry Canada To reduce potential radio interference to other users the antenna type and its gain must be so chosen that the equivalent isotropically radiated power e i r p is not more than that nec...

Page 6: ...g on the contents being displayed 1 When displaying the microphone input level When the AM CF1 unit is in use at a web conference etc only one LED facing in the direction of the speaker s voice lights...

Page 7: ...support 10BASE T or 100BASE TX When connecting the PoE extender use the following TPE 117GI made by TRENDnet 15 Power input terminal Connect a 12 V DC power source to this terminal For AC adapters us...

Page 8: ...o mount the AM CF1 unit to a wall Be sure to use the following wall mounting brackets and screws If hardware other than that mentioned below is used the unit could fall down potentially resulting in d...

Page 9: ...s removed in Step 1 Note Screws can be installed not only from the upward direction but also from the side or downward direction 7 CONNECTIONS 7 1 AC Adapter Connection Connect the AC adapter 1 to the...

Page 10: ...emove it straight away from the receptacle Do not pull on the cable to extract the plug as this may damage the connector OK NG Correct insertion direction Do not pull on the cable 7 4 AUX Input Connec...

Page 11: ...nections Use the supplied removable terminal plug 6 pins for connection Connect the control input and output blocks using 2 control lines from external control devices For removable terminal plug conn...

Page 12: ...is crushed possibly resulting in an excessive rise in joint temperatures Use cables of AWG 12 24 Terminal plug connections Step 1 Loosen the terminal screw then insert the cable Step 2 Retighten the t...

Page 13: ...or the multifunction indicators Saving and reading of the above setting data Maintenance Function Firmware update 8 2 System Requirements PC hardware requirements are as follows Display 1366 x 768 res...

Page 14: ...ion in progress Orange Normal operation mode Green Power OFF processing in progress Red Flashing blue green Blue Power standby mode Red Power OFF Extinguished 9 2 Switching between Power Standby and N...

Page 15: ...ont panel speaker can be adjusted when in Normal Operation mode While the volume is being adjusted the current output volume setting state is displayed by the front panel mounted multifunction indicat...

Page 16: ...e C terminal For example when terminals 1 2 have been allocated to Preset Memory Nos 1 2 in the contact input settings shorting individual terminals to the C terminal allows Preset Memory Nos 1 2 to b...

Page 17: ...Memory 1 2 to terminals The Preset Memory is accessed when its corresponding terminal is shorted to the C terminal If different Preset Memories are assigned to multiple terminals the last shorted term...

Page 18: ...Hold down the Power switch while confirming that the Power indicator is flashing blue green After approximately 30 seconds the Power indicator will light green and the USB connection indicator will li...

Page 19: ...che License 2 0 Apache 2 0 The 3 Clause BSD License The 2 Clause BSD License MIT License MIT Others We do not guarantee the operation of open source software itself but we do guarantee the functionali...

Page 20: ...ble terminal block 6 pins no voltage make contact relay contact output Network I F 10BASE T 100BASE TX RJ 45 Microphone Unidirectional electret condenser type Frequency Characteristics 20 Hz 20 kHz AU...

Reviews: