20.7. Monitoring the Unit's Operation Status
The operation status of the unit can be monitored in real time.
Step 1.
Double-click the "MaintCtrl.exe" icon to run the 9000 series
maintenance software.
The screen at right is displayed.
Step 2.
Click the "Others" button.
The window at right opens.
Tip
You can also set the communication port
and speed here when pressing the
"Option" button on the menu bar to
select "Communication Setting."
Step 3.
Click the "Start" button.
Operation status such as the
unit's key or knob actions is
displayed in real time.
[Screen indications and their descriptions]
3
Indication
Description
KEY INPUT SELECT 1
INPUT SELECT 1 key has been pressed.
KEY POWER long
Power switch has been pressed long.
KEY UTILITY & ESC/BACK
UTILITY key and ESC/BACK key have been pressed at the
same time.
ROTARY INPUT VOLUME L 1
INPUT VOLUME control has been turned one click
counterclockwise.
CIN CONTROL INPUT 2 (ON)
Control input 2 terminal has been turned on.
MATRIX MODE
Unit is operating in matrix mode.
MIXER MODE
Unit is operating in mixer mode.
POWER ON
Power has been turned on.