81
(C16) Control output terminal function display
C - O U T I N F
0 1
= N
O
N E
(C18) Control output terminal status display
(when all are open)
(C18) Control output terminal status display
(when all are closed)
C O U T = - - - - - - - - - - - -
C O U T = 1 2 3 4 5 6 7 8 9 A B C
(C17) Control output terminal status information
C -
O
U
T S
T
A
T
U
S
When STATUS is selected, current control output terminal statuses are displayed on the screen.
(C19) Remote control input terminal setting
R E M O T E S E T T I N G
Sets functions assigned to the remote control terminals (REMT VOL1 and REMT VOL2).
(C20) Remote controller type setting
R E M O T E
1
-> V O L U M E
Displays the function assigned to the control output terminal.
The screen indications represent the following functions:
• NONE:
No function is assigned.
• POWER:
Power ON
• LD SCENE:
Scene memory recall
• CH ON:
Channel ON
• CH MUTE:
Channel mute
• EMG MUTE: Emergency mute activation (All output channel mute)
• PG OUT:
Paging activation
Status of all control output terminals can be confirmed on the screen, with the terminal Nos. 1 – 12 arranged in
numerical order from left to right.
When closed, the terminal number is indicated by alpha-numerals. Alphabet A represents the terminal number
10, B represents 11, and C represents 12.
An open terminal is indicated by an underscore "_".
Set the type of remote controller connected to the remote control input terminals.
Use the Left and Right shift keys to move the setting items on the screen.
• OFF:
Select this setting when no remote controller is connected.
• VOLUME: Select this setting when a normal variable resistor or variable DC power supply unit is connected.
• ZM-9001: Select this setting when the ZM-9001 is connected. This setting adds 6 control inputs. These
inputs are assigned the functions in the setting screen on
• ZM-9002: Select this setting when the ZM-9002 is connected. This setting adds 4 control inputs and 1
remote volume control. These inputs are assigned the functions in the setting screens on
REMOTE 1, REMOTE 2
OFF (default), VOLUME, ZM-9001, ZM-9002
Setting Range
Remote Volume Terminal Number
Controller type