[Daisy-chain connection configuration]
The number of connected Remote control panels differs depending on the cable distance.
When 16 panels are connected, the maximum cable distance for each LINK A and LINK B is 200 m (220 yd).
Example 1:
When each cable for LINK A and LINK B is extended up to 200 m or 220 yd (400 m or 440 yd in
total), 16 panels can be connected irrespective of the distance between RC-001T and panels,
and between panels.
LINK A
LINK B
RC-001T
Remote control
panel (1)
(2)
(8)
(10)
(9)
(16)
200 m (220 yd) max.
200 m (220 yd) max.
Example 2:
When each cable for LINK A and LINK B is extended up to 300 m or 330 yd (600 m or 660 yd in
total), 14 panels can be connected irrespective of the distance between RC-001T and panels,
and between panels.
LINK A
LINK B
RC-001T
300 m (330 yd) max.
300 m (330 yd) max.
Remote control
panel (1)
(2)
(7)
(9)
(8)
(14)