TNT-OM # 7.2.3-041
Rev: 03-14-2016
10/30
Tool Operation:
1) Once the power unit, rescue tool and hydraulic twin line hose have been
properly connected and the pump control valve engaged to the pressure
position, the tool is ready to operate.
2) Check the operation of the rescue tool by turning the control valve on the
tool to the open and closed position.
Fully open and close the rescue tool
one to two times to purge any air from the system.
3) The Rescue tool is equipped with a dead man feature. When the valve is
released it will return to the neutral position and stop the operation of the
rescue tool.
4)
Once the use of the rescue tool is done or a tool change is needed, return
the control valve on the power unit to the neutral position
.(Note: TNT
hydraulic hoses and rescue tools are equipped with a pressure relieving
coupler, disconnecting hoses and or rescue tools with the control valve on
the power unit in the pressure position will cause hydraulic fluid to be
released to the environment.)
Rotate
Rotate
Open
Close
Summary of Contents for BFC-320
Page 17: ...TNT OM 7 2 3 041 Rev 03 14 2016 17 30 Warranty ...
Page 19: ...TNT OM 7 2 3 041 Rev 03 14 2016 19 30 SLC 24 10 500 PSI SPEC SHEET ...
Page 20: ...TNT OM 7 2 3 041 Rev 03 14 2016 20 30 SLC 28 10 500 PSI SPEC SHEET ...
Page 21: ...TNT OM 7 2 3 041 Rev 03 14 2016 21 30 SLC 29 10 500 PSI SPEC SHEET ...
Page 22: ...TNT OM 7 2 3 041 Rev 03 14 2016 22 30 BFC 320 10 500 PSI SPEC SHEET ...
Page 23: ...TNT OM 7 2 3 041 Rev 03 14 2016 23 30 MSDS Sheet ISO 68 Hydraulic Oil ...
Page 24: ...TNT OM 7 2 3 041 Rev 03 14 2016 24 30 ...
Page 25: ...TNT OM 7 2 3 041 Rev 03 14 2016 25 30 ...
Page 26: ...TNT OM 7 2 3 041 Rev 03 14 2016 26 30 ...
Page 28: ...TNT OM 7 2 3 041 Rev 03 14 2016 28 30 NOTES ...