TMS Lite
LC-18-1CH-X10 & 2CH-X5 CONTROLLER UNIT
25
4. Write to Slave
Command List
Command Code (YY) Command Description
Data
No. of Byte
SM
Set Channel Mode
0 = Constant
1 = Strobe
2 = Trigger
1
SR
Set Current Multiplier
1-10
2
SI
Set Intensity
0 - 255
3
SD
Set Strobe Delay
0 – 9999 (99.99ms) 4
SW
Set Strobe Width
0 – 9999 (99.99ms) 4
SY
Set Output Delay
0 – 9999 (99.99ms) 4
SH
Set Output Width
0 – 9999 (99.99ms) 4
ST
Strobe
NONE
0
EE
Save EEPROM
NONE
0
*Remark: For Save EEPROM function, use any channel no. for x value, all channels’
parameters will be saved
Return Message
Controller will send a return message same as the command sent to the controller to indicate
successful sending.
If wrong command or data are sent, a message of {ERR} in the bracket will be returned.
5. Read from Slave
Command List
Command Code (YY) Command Description
Return
Data (ZZZZ)
No. of Byte
RM
Read Channel Mode
0 = Constant
1 = Strobe
2 = Trigger
1
RR
Read Current Multiplier
1-10
2
RI
Read Intensity
0 – 255
3
RD
Read Strobe Delay
0 – 9999 (99.99ms)
4
RW
Read Strobe Width
0 – 9999 (99.99ms)
4
RY
Read Output Delay
0 – 9999 (99.99ms)
4
RH
Read Output Width
0 – 9999 (99.99ms)
4
RV
Read Version
WXYZ (W.X.Y.Z)
0
*Remark: For Read Version function, use any channel no. for x value