TMS Lite High Current Series User Manual Download Page 16

TMS Lite                          

LC-18-1CH-X10 & 2CH-X5 CONTROLLER UNIT

 

 

15 

 

Input Signal

 

Input signal is used to turn on the lighting under Strobe/Trigger mode.  
 
The lighting output is turned on after a delay time defined by Strobe Delay, while the turn on 
duration is defined by Strobe Width. 
 
Acceptable voltage for external input signal is from 3.3-24VDC.  
 
The external trigger signal can be configured as rising edge or falling edge trigger. 
 

 

 

 

 

Output Signal

 

The output signal is optional and is used to trigger external devices such as smart camera. The 
output signal is only available in Strobe Mode. 
 
The output pulse is  triggered after a delay time defined by Output  Delay, while the turn on 
duration is defined by Output Width. 
 
 

 

 

 

 

Summary of Contents for High Current Series

Page 1: ...2CH X5 CONTROLLER UNIT ________________________________________________________ ________________________________________________________ LC 18 1CH X10 LC 18 2CH X5 High Current Series Lighting Contro...

Page 2: ...Mode 7 Strobe Mode 7 Trigger Mode 8 Current Multiplier 8 LC 18 Software 9 Change IP Address 12 Slave Board Address Setting 13 Communication Connection 14 Input Signal 15 Output Signal 15 Accessories...

Page 3: ...LC 18 High Current Series Controller Package LC 18 M LC 18 2CH X5 LC 18 1CH X10 Ethernet Cable x1 RS232 Cable x1 Communication Cable x1set 24V Power Supply Optional Lighting Cable x 1pcs 2pcs Optiona...

Page 4: ...tion Parameter Value Controller Supply Voltage 24 VDC Lighting Supply Voltage 5 12 24 48 VDC According to Lighting Voltage Rating No of Channel LC 18 1CH X10 1 Channel LC 18 2CH X5 2 Channels Channel...

Page 5: ...ctors Description Terminal Function VS 24V Controller Power Supply GND Controller Power Supply COMM Communication Port between master and slave boards RS232 RS232 Communication TCPIP TCPIP Communicati...

Page 6: ...TMS Lite LC 18 1CH X10 2CH X5 CONTROLLER UNIT 5 Terminal Function LIGHT INPUT Power Supply for Lighting LIGHT INPUT Power Supply for Lighting CH Lighting Channel Output CH Lighting Channel Output...

Page 7: ...TMS Lite LC 18 1CH X10 2CH X5 CONTROLLER UNIT 6 Terminal Function IN External Input IN External Input OUT External Output OUT External Output...

Page 8: ...gnal will turn on the lighting output based on pre set delay and duration parameters There are 4 adjustable strobe parameters available Strobe Delay Delay time between the external input signal and th...

Page 9: ...ax output current 2000mA 5 50 of max output current 2500mA 6 60 of max output current 3000mA 7 70 of max output current 3500mA 8 80 of max output current 4000mA 9 90 of max output current 4500mA 10 10...

Page 10: ...COMPORT or TCPIP to connect b Disconnect the software 2 Read and Save function for all slave board a Read all slave board s parameter from controller b Save all slave board s parameter into EEPROM 3...

Page 11: ...trobe once 10 Tick the checkboxes to set the address Address must be same as the ADDR setting on the controller 11 Choose the channel to be strobe 12 Save current slave board parameter to EEPROM 13 Ch...

Page 12: ...TMS Lite LC 18 1CH X10 2CH X5 CONTROLLER UNIT 11 LC 18 1CH X10 1 Channel only...

Page 13: ...P Config software Default IP Setting IP Address 192 168 0 100 Subnet Mask 255 255 255 0 Gateway 192 168 0 1 Step 1 Connect using COMPort or TCPIP Current IP will be displayed 2 Type in the new IP addr...

Page 14: ...ess number 0 15 SWITCH NO 0 1 2 3 BINARY VALUE 20 21 22 23 ADDRESS 0 0 0 0 0 ADDRESS 1 1 0 0 0 ADDRESS 2 0 1 0 0 ADDRESS 3 1 1 0 0 ADDRESS 4 0 0 1 0 ADDRESS 5 1 0 1 0 ADDRESS 6 0 1 1 0 ADDRESS 7 1 1 1...

Page 15: ...18 1CH X10 2CH X5 CONTROLLER UNIT 14 Communication Connection All the COMM connector must be looped together for the communication between slave boards All COMM1 and COMM2 must be looped together as...

Page 16: ...by Strobe Width Acceptable voltage for external input signal is from 3 3 24VDC The external trigger signal can be configured as rising edge or falling edge trigger Output Signal The output signal is o...

Page 17: ...s that can be used with LC 18 16CH A1 controllers 24V power supply Lighting cable 24V Power Supply MODEL SPECIFICATIONS 24V POWER SUPPLY WITH POWER CORD 24V 2 5A UK 24V ADAPTOR WITH POWER CORD UK 24V...

Page 18: ...TMS Lite LC 18 1CH X10 2CH X5 CONTROLLER UNIT 17 Cable Selection XX Length XX Length MODEL POWER LENGTH EXT 24V F XX 24V 3M 5M MODEL POWER LENGTH EXT FL M12F XX 24V 3M 5M...

Page 19: ...TMS Lite LC 18 1CH X10 2CH X5 CONTROLLER UNIT 18 Cable Information i EXT 24V F 3M Extension Cable of 3 Meter with SM connector iii EXT FL M12F 3M Extension Cable of 3 Meter with M12 connector...

Page 20: ...TMS Lite LC 18 1CH X10 2CH X5 CONTROLLER UNIT 19 Power Cord Information The cable length is 1 8 Meter length of power cord 240VAC Power Cord UK 220VAC Power Cord EU 110VAC Power Cord US...

Page 21: ...TMS Lite LC 18 1CH X10 2CH X5 CONTROLLER UNIT 20 Drawing Dimension LC 18 1CH X10...

Page 22: ...TMS Lite LC 18 1CH X10 2CH X5 CONTROLLER UNIT 21 LC 18 2CH X5...

Page 23: ...ault IP 192 168 0 100 Default Subnet Mask 255 255 255 0 Default Gateway 192 168 0 1 2 Master Command Message Format ASCII Write YY ZZZZ Starting Byte Command Code Open Bracket Data Close Bracket End B...

Page 24: ...Gateway REMARK Do a power restart on the Master Unit for the new IP Address to come into effect Example Set IP Address 192 168 0 123 Tx MSI 192 168 000 123 Rx MSI 192 168 000 123 Update IP on Master T...

Page 25: ...ard Address Channel No Command Code Open Bracket Close Bracket End Byte Return Message W X YY ZZZZ Starting Byte Board Address Channel No Command Code Open Bracket Data Close Bracket End Byte Starting...

Page 26: ...annels parameters will be saved Return Message Controller will send a return message same as the command sent to the controller to indicate successful sending If wrong command or data are sent a messa...

Page 27: ...H1 Intensity 90 Tx 01SI 90 Rx 01SI 90 Success 4 Set CH1 Strobe Width 500 50 0ms Tx 01SW 500 Rx 01SW 500 Success 5 Strobe CH1 Tx 01ST Rx 01ST Success 6 Save EEPROM parameter Tx 01EE Rx 01EE Success Boa...

Page 28: ...x 01RR 02 Success 4 Read CH1 Intensity 150 Tx 01RI Rx 01RI 150 Success 5 Read CH2 Strobe Delay 500 50 0ms Tx 02RD Rx 02RD 0500 Success 6 Read CH2 Strobe Width 2000 200 0ms Tx 02RW Rx 02RW 2000 Success...