TMC BLUE BELLE CHIC/TO Instructions For Use Manual Download Page 5

 

dormitories, in boats, recreational vehicles and in rooms located on a high floor of a building. Any other use, 
or  the  extended  use  of  the  appliance,  is  to  be  considered  improper  use  and  the  user  will  be  held 
responsible for any possible consequent risk.  

 
2.3 Safety devices 

The product has been designed to prevent hazards thanks to the presence of the following safety devices: 
 

Thermocouple 

The  pilot  flame heats  up  a  thermocouple  which, in  turns,  keeps  the  valve  of  the  appliance open  (not  the 
valve of the cylinder). If the pilot flame goes out, the gas flow from the valve to the appliance automatically 
stops within approximately one minute. 
 

ODS 
A  pilot  flame with an  ODS  system  goes  out  and  stops  the  gas  supply 
before the level of CO2 exceeds the 1.5% limit (in the room where the 
room is used).

 

To prevent activation of the ODS system, the gas stove must  be used only 
and exclusively in well-ventilated rooms.  
Ensure  that  the  room  is  suitably  ventilated  and,  if  the  ODS  system  has 
triggered, ventilate the room. If you need to intervene too often, this means 
that the room is too small or that ventilation is not sufficient. 
 

Minimum recommended volumes 

 
 
 
 
 
 
 
 
 
 
 

Heatable volumes with the useful power of the stove (maximum 

efficiency power) 

 

 

 

 

 

 

  

  

Outdoor temperature 

 

  

  

-10 °C 

-5 °C 

0 °C 

  

Insulation 

degree  

GOOD 

(U

m

 = 0.20)

 

280 

350 

420 

Volume in m

3

 

AVERAGE 

(U

m

 = 

0.50)

 

150 

182 

221 

POOR 

(U

m

 = 1.00)

 

84 

100 

123 

 

Key: 

 

 

 

 

 

Um: indicates the average transmittance value of all the dispersion structures present in the room to be heated (W/m2.K)   

 

 

 

 

 

 

 

 

Important remarks:   

 

 

 

 

the values shown in the table refer to "standard" domestic rooms with a temperature of 20 °C ± 2°C 

 

 

 

 

 

The rooms heated directly by the appliance should not feature partition walls; in other words, they should be free from inner barriers.  
 

 

 

 

 

 

 

The table is for information purposes only. Considering that there are many parameters involved, we recommend contacting a thermos-technical 
engineer in order to obtain a final evaluation. 

 

 

 

 

 

 

 

With ON OFF 
thermostat 

Automatically variable 

Power 4.2 kW  

Heatable volumes: 
 
Sitting room  
 
Other rooms 

 

 

 84 m

3

 

 

42 m

 

Summary of Contents for BLUE BELLE CHIC/TO

Page 1: ...class A A G THIS PRODUCT IS NOT SUITABLE FOR PRIMARY HEATING Instructions for use BLUE BELLE CHIC TO Free flame heater Household appliance Keep this manual for future reference Original in Italian SOB...

Page 2: ...e WARNING AND SAFETY SECTIONS indicated by the symbol Warning Warning failure to comply with the information given in this manual may result in fire or explosions that may damage properties and injure...

Page 3: ...packaging 3 2 Keeping the original packaging 3 3 Connecting the stove to the gas cylinder 3 4 Checking for leaks in the regulator 3 4 1 Checking for leaks in the regulator 3 5 Installing the gas cyli...

Page 4: ...ved approval by the German certification body DVGW and complies with Gas European appliance regulation 2016 426 EU This stove is tested according to EU gas regulation as well as to EN 449 and complies...

Page 5: ...the room is suitably ventilated and if the ODS system has triggered ventilate the room If you need to intervene too often this means that the room is too small or that ventilation is not sufficient M...

Page 6: ...should only be allowed to use the appliance once they have been given the appropriate instructions The appliance is not intended to be used by persons children included with reduced physical sensory o...

Page 7: ...1 2 m s ATTENTION Do not point fans directly toward the stove Avoid air currents that may change the flame of the burner When connecting the cylinder for the first time and any time the cylinder needs...

Page 8: ...ispose of the packaging at the end of the life cycle of the appliance For further information on correct disposal please refer to chap 8 3 3 Connecting the stove to the gas bottle Never position the c...

Page 9: ...until you hear a click NOTE The regulator can only be fitted to the cylinder valve when the control knob is in the OFF position Turning the regulator on After fitting the regulator correctly onto the...

Page 10: ...position of the vent hole 6 Until the time of installation the product must be stored in a clean dry location protected from weather atmospheric agents and direct sunlight It must not be knocked or d...

Page 11: ...nection Open the regulator knob Wait at least 20 seconds before opening the regulator again 2 In case of the flow of gas being higher than the capacity of the regulator contact your gas supplier Maxim...

Page 12: ...the stove and contact your seller see chapter 6 Repair works or faulty component replacement must be carried out by qualified technicians who must use original components ATTENTION Ensure that the ga...

Page 13: ...eplacing the cylinder ensure that the room is suitably ventilated Ensure that the gas valve is safely closed Do not use any tool to remove the pressure regulator just disconnect the regulator in accor...

Page 14: ...he flame in the burner is yellow The gas cylinder is running low Dirty gas The room is very dusty When walking near the stove dust is sprayed around Replace the cylinder The flame slowly stabilizes on...

Page 15: ...rranty period will be charged to the purchaser The warranty shall be invalidated in case of damages during transport or damages due to lack of care unintended use incorrect installation or failure to...

Page 16: ...ce with the instructions and respecting the polarity The electronic ignition block contains an AAA type battery To replace the battery turn the top of the piezoelectric igniter see Fig 5 anti clockwis...

Page 17: ...ve 2009 125 EU the regulations 2015 1186 EU 2015 1188 EU and in compliance with the harmonized standard EN 449 2002 A1 2007 and are subjected to EC type approval test Notified body CE 0085 has issued...

Page 18: ...procedure s specified in the Regulation 2016 426 on gas appliances as brought into UK law and amended Annex III Module B Type Examination and issued the Certificates below UKCA Module B certificate UK...

Page 19: ...heat output elmax x xxx kW single stage heat output no room temperature control No At minimum heat output elmin x xxx yes no two or more manual stages no room temperature control No In standby mode el...

Page 20: ...diretta Direct power heat imput Potencia t rmica directa Direkte thermische Leistung Puissance thermique directe 4 2 kW e Potenza termica indiretta Indirect power heat imput Potencia t rmica indirect...

Reviews: