DATAPLEX DEVICES—Node 1x6 User Manual v1.1—25112020                                                       

18

 

 

 

PROTOCOL

 

SETUP 

 

Set up lighting protocol information intended for the Node 1x6. All settings changed in this page are only applied 
after selecting the SET button at the bottom right of the screen. 

 
 
 
 
 
 
 
 
 
 
 
 
 

PROTOCOL SELECT

Choose between Art-Net, sACN or Art-Net+sACN. Protocols are changed with a 

dropdown menu, which applies to all ports of the node.  
 
 
 
 
 
 

EASY PRIORITY

Activating Easy Priority is useful for sharing a rig between multiple consoles. When two or 

more of the same Art-Net/ sACN universes from different sources try to send DMX to a Node 1x6 output port, the 
source with the higher channel 512 value for that universe will assume control over it. Using simple submasters 
with channel 512 recorded to full, one console can take over control of a universe from another without any form 
of complex HTP/LTP merging in the system. EASY PRIORITY is enabled with a dropdown menu. 
 
 
 
 
 

ACTION ON SOURCE LOSS

Determines what will happen if the Node 1x6 loses its source of Art-Net or 

sACN. Action is selected with a dropdown menu, and any timing is specified with the entry field.  

HOLD OUTPUT: holds the last DMX values the Node 1x6 received 
BLACKOUT AFTER: takes all DMX channels to 0% after a set amount of time 
DISABLE OUTPUT AFTER: disables the DMX output altogether after a set amount of time 
 
 
 
 
 
 

DMX OUT REFRESH RATE

Changes the DMX out refresh rate between 20Hz, 30Hz, 40Hz, and Adaptive. 

Adaptive mode (High Speed Video Adaptive Mode), is best used when a media server or lighting console is 
sending DMX over Ethernet at a higher rate than typical, for the purposes of having DMX Fixtures (LEDs) behave 
like low-resolution video. Note: Some devices may not work with this setting. 

 
 
 
 
 

Summary of Contents for DATAPLEX DPNODE663PTB

Page 1: ......

Page 2: ...oduction modification or distribution of this document for any other purposes without express written consent Specifications are subject to change without notice The information in this document super...

Page 3: ...BOOKMARK NOT DEFINED RDM DMX SERIAL LINK NODE 1X6 PTB 13 RDM DMX SERIAL LINK NODE 1X6 IDC ERROR BOOKMARK NOT DEFINED OPERATION ERROR BOOKMARK NOT DEFINED OVERVIEW 15 BROWSER INTERFACE ERROR BOOKMARK...

Page 4: ...me responsibility for any labor expended or materials used to replace and or repair the Product without TMB s prior written authorization Any repair of the Product in the field and any associated labo...

Page 5: ...glitch free data processing of up to six universes o Control and management via ProPlex Software or web browser interface o Merge DMX Art Net and Streaming ACN from multiple sources o Bi directional R...

Page 6: ...DATAPLEX DEVICES Node 1x6 User Manual v1 1 25112020 6 MODEL ILLUSTRATION...

Page 7: ...DATAPLEX DEVICES Node 1x6 User Manual v1 1 25112020 7 DIMENSIONS NODE 1X6 XLR...

Page 8: ...DATAPLEX DEVICES Node 1x6 User Manual v1 1 25112020 8 DIMENSIONS NODE 1X6 PTB...

Page 9: ...DATAPLEX DEVICES Node 1x6 User Manual v1 1 25112020 9 DIMENSIONS NODE 1X6 IDC...

Page 10: ...user make sure they also receive this instruction booklet o Ensure the unit is connected to proper voltage and that line voltage is not higher than that stated on the device o Make sure there are no f...

Page 11: ...REPLACEMENT Dataplex Node 1x6 uses a 1 0A 250V barrel fuse 5x20mm 0 2x0 8 in To replace fuse 1 With a screwdriver open the fuse drawer to access the fuse 2 Remove old fuse and fasten new fuse securely...

Page 12: ...DMX ports A F and link to fixtures Opto Splitters or other equipment as necessary Each port can be configured either as DMX output or input via the Web Interface or ProPlex Software Note When enabling...

Page 13: ...e and data negative conductors 1 Strip the bare end wire insulation back 7mm or roughly inch from cable end 2 Insert bare wires into connector per the diagram below Turn each connector set screw with...

Page 14: ...e same diagram for common data positive and data negative conductors 1 Insert a small screwdriver into each of the 3 orange tabs on the IDC connector Using gentle upwards pressure push open the tabs t...

Page 15: ...m ProPlex Software which allows total visibility and management of all connected nodes in one easy to use program The ProPlex Software can be downloaded for free on our website www tmb com BROWSER INT...

Page 16: ...n NODE NAME Change the name of the node to a desired name The value in this field is directly editable and can be used to differentiate Nodes by area or placement e g Truss 1 FOH 2 or Server Room East...

Page 17: ...displayed according to the Universe Number format If the number entered is in a different format than the selected format the entered number will be converted to the selected Universe Number format e...

Page 18: ...ull one console can take over control of a universe from another without any form of complex HTP LTP merging in the system EASY PRIORITY is enabled with a dropdown menu ACTION ON SOURCE LOSS Determine...

Page 19: ...n file in the text box and select Set Name DEFAULTS Clear all settings in the Node 1x6 PORT DEFAULTS Reset all DMX port related settings PROTOCOL DEFAULTS Reset all protocol related settings sACN Art...

Page 20: ...plex Node 1x6 firmware is a simple process of browsing for the firmware file destination and selecting the Upgrade button The firmware upgrade screen will indication a complete and successful firmware...

Page 21: ...OPLEX SOFTWARE ProPlex Software v2 includes a full suite of configuration and monitoring features and simplifies managing multiple nodes on a network The software is available for free on our website...

Page 22: ...DEVICES Node 1x6 User Manual v1 1 25112020 22 FRONT PANEL LED INDICATORS POWER STATUS NETWORK STATUS PORT STATUS The Dataplex Node 1x6 has multicolor activity LEDs for each output port on the front of...

Page 23: ...DATAPLEX DEVICES Node 1x6 User Manual v1 1 25112020 23 REAR PANEL LED INDICATORS NETWORK STATUS...

Page 24: ...C Terminal Block Network Protocol Art Net sACN E1 31 RDM Support Yes DMX Isolation Optical up to 1000V Power Input 100 240 VAC 50 60 Hz Power Consumption 10W Power Connector IEC with fuse holder accep...

Page 25: ...RMA prior to shipping the unit Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to properly pack the unit any shipping damage resulting...

Page 26: ...T H I S P A G E I N T E N T I O N A L Y B L A N K...

Page 27: ...T H I S P A G E I N T E N T I O N A L Y B L A N K...

Page 28: ...418 techsupport tmb com LOS ANGELES 1 818 899 8818 LONDON 44 0 20 8574 9700 NEW YORK 1 201 896 8600 BEIJING 86 10 8492 1587 CANADA 1 519 538 0888 A full service company providing technical support cus...