8. Estimating Leak Level, Saving and Recalling Data
072-65284M-02 (SonicMan SN1) 24 Feb 2005
17
8.3
Record Number Selection
It is possible to select any three-digit number from 000 to 999
as a record number for the data. Record numbers do not have
to be continuous.
1) The cursor will begin blinking in the record number box. A
number that is sequentially higher than the highest
currently in memory is automatically displayed.
2) Pressing the [
×
] or [
Ø
] buttons causes the record number
to increase or decrease by one.
3) Pressing the [
×
] button once while the automatically
displayed record number is visible causes “CSL” (cancel)
to be displayed. This indicates that you do not wish to
save this held record (discarding the data).
8.4
Saving the Inspection Data in the Internal Memory
The reading value, sensitivity setting, estimated leakage
amount and its conditions can be saved together with the
record number in the internal memory.
1) Confirm the record number to be used, then press the
[Memory] button.
(a) The message “Complete Data Store” is momentarily
displayed while the unit saves the inspection data.
The
SonicMan
will then return to detection mode.
(b) If the selected record number was “CSL”, the data is
discarded without saving.
SonicMan
then returns to
detection mode.
(c) Measurement data can be stored even if the leak level was not calculated.
2) If the selected record number has already been used,
SonicMan
will query: “Over write?”
(a) To destroy the previous data and save the new data
(overwrite), press the [Memory] button once more.
The message “Data Store” is momentarily displayed
while the unit saves the data.
SonicMan
then returns
to detection mode.
(b) To save without overwriting, use the [
×
] and [
Ø
]
buttons to select a different record number, then pres
[Memory] to save the data.
(c) To cancel a data save, press the [
×
] and [
Ø
] buttons
to change the record number to “CSL” for cancellation and press the [Memory]
button one more time. Then,
the SonicMan
will return to detection mode without
the message, “Data Store”.
SonicMan will return to detection mode without displaying the data saved
message.
Record Number Selection
No.001 *
No.001 *
No.001 *
No.001 *
L:
L:
L:
L:
---
---
---
---
60dB S 50
60dB S 50
60dB S 50
60dB S 50
No.001
*
*
*
*
L
:
::
:
1
60 S 50
Overwriting Records
Over write? *
Over write? *
Over write? *
Over write? *
L:
L:
L:
L:
---
---
---
---
60dB S 50
60dB S 50
60dB S 50
60dB S 50
Over write?
*
*
*
*
L:
---
60 S 50
Overwrite
Don’t
Overwrite
Memory
Memory
Cancel Data Store
Press 1 time
No.CSL *
No.CSL *
No.CSL *
No.CSL *
L:
L:
L:
L:
---
---
---
---
60dB S 50
60dB S 50
60dB S 50
60dB S 50
No.CSL
*
*
*
*
L:
1
60 S 50
Saving Data
No.001 *
No.001 *
No.001 *
No.001 *
L:
L:
L:
L:
---
---
---
---
60dB S 50
60dB S 50
60dB S 50
60dB S 50
No.001
*
*
*
*
L
:
::
:
1
60 S 50
Complete *
Complete *
Complete *
Complete *
Data Store
Data Store
Data Store
Data Store
Complete
*
*
*
*
Data Store
Memory