7. Operation
072-65284M-02 (SonicMan SN1) 24 Feb 2005
14
7 Operation
7.1
Turning the Power ON and OFF
1) Pulling (clicking) the trigger once turns the power ON.
2) After turning the power ON, you may immediately begin
to search for leaks. It is not necessary to pull the trigger
again.
3) Pulling the trigger twice in a less than 1-second interval
(double-clicking) turns the power OFF.
Note: The power can only be turned OFF when
SonicMan
is in detection mode. The power cannot be turned
OFF if it is in setting-modification mode, data recall
mode, etc.
7.2
Attaching the Earphones (In Quiet Areas)
1) Lift up the cover for the
SonicMan
earphone jack
c
.
2) Insert the earphone plug into the
SonicMan
earphone
jack
d
.
3) The earphone with the “R” is for the right ear and the
one with the “L” is for the left ear.
7.3
How to Read the Screen
c
d
The reading is displayed by a bar indicator.
The bar length (number of squares shown)
indicates level presently being detected.
This icon displays
battery voltage in 4
levels. It blinks when
battery strength
becomes weak.
This displays the reading
as a quantitative value
from 0 to 100.
This is displayed
when the laser
pointer output is ON.
This marks the maximum level reached
during leak detection. If the sensitivity
setting is modified, this reading is deleted.
This displays the current
sensitivity setting as a
quantitative value.