172-65417MA-05  (FS21-L/FS21-H  +  BD2)    4  Oct  2021

 

14 

Instructions for Plug/Holder Disassembly and 
Reassembly

 

The seal on the threaded plugs/holders found on TLV products is formed by a flat metal 
gasket. There are various installation orientations for the gaskets, such as horizontal, 
diagonal and downward, and the gasket may be pinched in the thread recesses during 
assembly. 

 

Instructions for Disassembly and Reassembly 

 

Remove the plug/holder using a tool of the specified size (distance across flats). 

 

The gasket should not be reused. Be sure to replace it with a new gasket. 

 

Clean the gasket surfaces of the 
plug/holder and the product body using 
a rag and/or cleaning agents, then 
check to make sure the surfaces are not 
scratched or deformed. 

 

Coat both the gasket surface of the 
plug/holder and the threads of the 
plug/holder with anti-seize, then press 
the gasket onto the center of the 
gasket surface of the plug/holder, 
making sure the anti-seize affixes the 
gasket tightly to the plug/holder. Check 
to make sure the gasket is not caught 
in the recesses of the threads. 

 

Hold the plug/holder upside down to 
make sure that the anti-seize makes 
the gasket stick to the plug/holder 
even when the plug/holder is held 
upside down. 

 

Screw the plug/holder by hand into the 
product body while making sure that 
the gasket remains tightly affixed to 
the center of the gasket surface of the plug/holder. Make sure the entire gasket is 
making contact with the gasket surface of the product body. It is important at this 
point to make sure the gasket is not pinched in the thread recesses of the 
plug/holder. 

 

Tighten the plug/holder to the proper torque. 

 

Next, begin the supply of steam and check to make sure there is no leakage from 
the part just tightened. If there is leakage, immediately close the inlet valve and, if 
there is a bypass valve, take the necessary steps to release any residual pressure. 
After the surface of the product cools to room temperature, repeat the procedure 
beginning from step 1. 

Summary of Contents for QuickTrap FS21-H

Page 1: ...72 65417MA 05 FS21 L FS21 H BD2 4 October 2021 Free Float Steam Trap QuickTrap FS21 L FS21 H Trap Unit S21 L S21 H Copyright 2021 by TLV CO LTD All rights reserved Instruction Manual Instruction Manua...

Page 2: ...ound float and three point support for the valve body The three point seating for the valve body supports the precision ground float securely at three points and ensures a high degree of sealing for e...

Page 3: ...Indicates a DANGER WARNING or CAUTION item Indicates an urgent situation which poses a threat of death or serious injury Indicates that there is a potential threat of death or serious injury Indicate...

Page 4: ...mmended components when repairing the product and NEVER attempt to modify the product in any way Failure to observe these precautions may result in damage to the product and burns or other injury due...

Page 5: ...installed 5 Is the inlet pipe as short as possible with as few bends as possible and installed so the liquid will flow naturally down into the product 6 Has the piping work been done correctly as show...

Page 6: ...valve when steam is first supplied to the system 2 Condensate Discharge If the temperature of the condensate rises above 90 C 194 F the bimetal air vent strip expands allowing the float to block the v...

Page 7: ...roduct leading to fluid discharge which may cause burns or other injury CAUTION Refer to the product nameplate for detailed specifications Maximum allowable pressure PMA and maximum allowable temperat...

Page 8: ...Orifice 16 Snap Ring 5 Orifice Gasket 17 Connector Flange 6 Screen 18 Connector Body 7 Cover Gasket 19 Screen 8 Cover Bolt 20 Screen Holder Gasket 9 Air Vent Strip 21 Screen Holder 10 Screw 22 Connect...

Page 9: ...ut the inlet piping to remove any piping scraps dirt and oil Close the inlet valve after blowdown 3 Install the product so the arrow on the body is pointing in the direction of condensate flow 4 The c...

Page 10: ...roducts with screwed connections are installed on horizontal piping there is a danger that the weight of the trap unit will cause the connector body to rotate on the pipe putting the trap mechanism ou...

Page 11: ...uously together with flash steam and the sound of flow can be heard If there is very little condensate there is almost no sound of flow Blocked Discharge Impossible No condensate is discharged The pro...

Page 12: ...e assembly and prevent loosening of the gaskets apply a small amount of adhesive at 120 intervals around the outer edge of the gaskets Attaching the Trap Unit to the Connector Body Figure A 1 If attac...

Page 13: ...ening torques and tighten to the proper torque Orifice Gasket Remove the gasket and clean sealing surfaces Replace with a new gasket Disassembly Reassembly of Components Inside the Connector Body Part...

Page 14: ...w Spring Washer Float Cover Gasket Screw Spring Washer Connector Orifice Orifice Gasket Cover Cover Bolt Connector Body Connector Bolt Screen Screen Holder Gasket Screen Holder Nameplate Connector Fla...

Page 15: ...face of the plug holder making sure the anti seize affixes the gasket tightly to the plug holder Check to make sure the gasket is not caught in the recesses of the threads Hold the plug holder upside...

Page 16: ...fficient pressure differential between the product inlet and outlet Compare specifications and actual operating conditions Steam locking has occurred Perform a bypass blowdown or close the trap inlet...

Page 17: ...e maintenance or repair or 7 operation of the Products not in accordance with instructions issued with the Products or with accepted industry practices or 8 use for a purpose or in a manner for which...

Page 18: ...DAMAGE TO BUYER S OR THE FIRST END USER S PRODUCT DAMAGE TO BUYER S OR THE FIRST END USER S PROCESSES LOSS OF USE OR OTHER COMMERCIAL LOSSES WHERE DUE TO OPERATION OF LAW CONSEQUENTIAL AND INCIDENTAL...

Page 19: ...ks Road Nunawading Victoria 3131 Australia Tel Fax 61 0 3 9873 5610 61 0 3 9873 5010 In East Asia 36 Kaki Bukit Place 02 01 02 Singapore 416214 Tel Fax 65 6747 4600 65 6742 0345 Room 5406 No 103 Cao B...

Page 20: ...et to avoid contact with internal fluids that will be discharged Operate the valve slowly and surely taking care to avoid the area from which internal fluids are discharged and any fluids deflected of...

Page 21: ...with another wrench and slowly loosen Condensate and steam will discharge from the blow outlet in a jet stream Be careful not to loosen the BD2 valve so far that it becomes removed from the BD2 valve...

Reviews: